• ABB 1SAM340000R1013 MS132-20T Circuit Breaker for Primary Transformer Protection Product Image
  • Abb 1SAM340000R1013 Barcode

1SAM340000R1013

Product Summary:

  • Extended Product Type: MS132-20T
  • Product ID: 1SAM340000R1013
  • EAN: 4013614485039
  • Criticality: No
  • Country of Origin: Germany (DE)
Let Us Find It
           or           
  • Description: MS132-20T Circuit Breaker for Primary Transformer Protection
  • Rated Insulation Voltage (Ui): 690 V
  • Power Loss: at Rated Operating Conditions per Pole 1.0 1.6 W
  • Number of Poles: 3
  • Conventional Free-air Thermal Current (Ith): 20 A Main Circuit 20 A
  • Degree of Protection: Housing IP20 Main Circuit Terminals IP10
  • Pollution Degree: 3
  • Electrical Durability: 50000 cycle
  • Mechanical Durability: 100000 cycle
  • Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 0.75 ... 6 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm² Flexible 1/2x 1 ... 2.5 mm² Flexible 1/2x 2.5 ... 6 mm² Rigid 1/2x 1 ... 2.5 mm² Rigid 1/2x 2.5 ... 6 mm²
  • Tightening Torque: Main Circuit 2 N·m
  • Wire Stripping Length: Main Circuit 10 mm
  • Recommended Screw Driver: M4 Pozidriv 2
  • Mounting Position: Position 1 to 6
  • Actuator Type: Rotary Handle
  • Contact Position Indication: ON / OFF / TRIP
  • Standards: IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1
  • Ambient Air Temperature Compensation: Yes
  • Maximum Operating Altitude Permissible: 2000 m
  • Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
  • Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 3 ... 150 Hz
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Ambient Air Temperature: Around the Enclosure 0 ... +40 °C Operation -25 ... +70 °C Storage -50 ... +80 °C
  • Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 16-8 AWG Stranded 1/2x 16-8 AWG
  • Tightening Torque UL/CSA: Main Circuit 16 in·lb
  • Data Sheet, Technical Information (Part 2): 1SAM300535F0013
  • Instructions and Manuals: 2CDC131057M6801
  • CCC Certificate: 1SAA963001-3804
  • cULus Certificate: cUL_E137861
  • cUR Certificate: cUL_E137861
  • Data Sheet, Technical Information: 2CDC131058D0201
  • Declaration of Conformity - CE: 1SAD938502-0188
  • GOST Certificate: 1SAA937000-2703
  • RoHS Information: 1SAA963002-4405
  • ETIM 4: EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 5: EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 6: EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • eClass: 7.0 27370409
  • Object Classification Code: F
  • Extended Product Type: MS132-20T
  • Product ID: 1SAM340000R1013
  • EAN: 4013614485039
  • Criticality: No
  • Product Availability Class: From stock if available, otherwise maximum delivery time
  • Country of Origin: Germany (DE)
  • Lead Time: 42 day(s)
  • Warranty Return: Product under warranty must be returned
  • Note: No
  • Country of Origin: Germany (DE)
  • Lead Time: 42 day(s)
  • Made To Order: No
  • Product Sales Status: Active
  • Quote Only: No
  • Stocked At Warehouses: SGRDC002EXPU
  • Warranty Return: Product under warranty must be returned
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85362010
  • EAN: 4013614485039
  • Package Level 1 Width: 92 mm
  • Package Level 1 Length: 102 mm
  • Package Level 1 Height: 50 mm
  • Package Level 1 Gross Weight: 0.325 kg
  • Package Level 2 Units: 40 piece
  • Package Level 2 Width: 280 mm
  • Package Level 2 Length: 395 mm
  • Package Level 2 Height: 210 mm
  • Package Level 2 Gross Weight: 13.386 kg
  • Package Level 2 EAN: 4013614487231
  • Package Level 1 Units: 1 piece
  • Product Net Height: 97.8 mm
  • Product Net Depth: 86.05 mm
  • Product Net Weight: 0.31 kg
  • Product Net Width: 45 mm
  • Rated Instantaneous Short-Circuit Current Setting (Ii): 400 A
  • Setting Range: 16 ... 20 A
  • Rated Operational Voltage: Main Circuit 690 V AC
  • Rated Operational Current (Ie): 20 A
  • Rated Frequency (f): Main Circuit 50 Hz Main Circuit 60 Hz
  • Rated Impulse Withstand Voltage (Uimp): Main Circuit 6 kV
Santa Clara Systems specialises in hard-to-find parts. Choose from our overstock inventory and save on 1SAM340000R1013 . Santa Clara Systems carries 35,877 items from ABB.
  • Undervoltage Releases
  • Shunt Trips
  • Power In-Feed Blocks Are Available As Accessory.
  • The Circuit Breaker For Transformer Protection Ms132-20T Is A Compact 45 Mm Width Device Designed To Protect Control Transformers On The Primary Side. This Device Has A Rated Operational Current Of Ie = 20 A. It Allows Fuse-Less Protection Against Overload And Short-Circuit. The Short-Circuit Current Setting Is Fixed To 20 Times The Rated Operational Current To Handle The High Inrush Current Generated By Transformers. The Device Allows Manually Connect And Disconnect The Transformer From The Mains Thanks Of Its Built-In Disconnection Function. The Circuit Breaker For Transformer Protection Offers A Rated Service Short-Circuit Breaking Capacity Of Ics = 100 Ka At 400 Vac And A Trip Class 10. Further Features Are Temperature Compensation
  • Trip-Free Mechanism
  • Rotary Handle With A Clear Switch Position Indication And Short Circuit Trip Indicator. The Handle Is Lockable To Protect Against Unauthorized Changes. Auxiliary Contacts
  • Signalling Contacts
  • Alternates

    • MS132-20T
    • MS132 20T
    • MS13220T

    Common Types

    • 1SAM340000R10I3
    • 1SAM340000R10L3
    • 1SAM340000R1O13
    • 1SAM340000R1OI3
    • 1SAM340000R1OL3
    • 1SAM340000RI013
    • 1SAM340000RI0I3
    • 1SAM340000RI0L3
    • 1SAM340000RIO13
    • 1SAM340000RIOI3
    • 1SAM340000RIOL3
    • 1SAM340000RL013
    • 1SAM340000RL0I3
    • 1SAM340000RL0L3
    • 1SAM340000RLO13
    • 1SAM340000RLOI3
    • 1SAM340000RLOL3
    • 1SAM34000OR1013
    • 1SAM34000OR10I3
    • 1SAM34000OR10L3
    • 1SAM34000OR1O13
    • 1SAM34000OR1OI3
    • 1SAM34000OR1OL3
    • 1SAM34000ORI013
    • 1SAM34000ORI0I3

    Appended Numbers

    • 1SAM340000R1013-A
    • 1SAM340000R1013-B
    • 1SAM340000R1013-C
    • 1SAM340000R1013-D
    • 1SAM340000R1013-E
    • 1SAM340000R1013-F
    • 1SAM340000R1013-G
    • 1SAM340000R1013-H
    • 1SAM340000R1013-I
    • 1SAM340000R1013-J
    • 1SAM340000R1013-K
    • 1SAM340000R1013-L
    • 1SAM340000R1013-M
    • 1SAM340000R1013-N
    • 1SAM340000R1013-O
    • 1SAM340000R1013-P
    • 1SAM340000R1013-Q
    • 1SAM340000R1013-R
    • 1SAM340000R1013-S
    • 1SAM340000R1013-T
    • 1SAM340000R1013-U
    • 1SAM340000R1013-V
    • 1SAM340000R1013-W
    • 1SAM340000R1013-X
    • 1SAM340000R1013-Y
    • 1SAM340000R1013-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier Domestic and International
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo