• ABB 1SBL297001R1122 AF38-30-22-11 24-60V50/60HZ 20-60VDC Contactor Product Image
  • Abb 1SBL297001R1122 Barcode

1SBL297001R1122

Product Summary:

  • Extended Product Type: AF38-30-22-11
  • Product ID: 1SBL297001R1122
  • EAN: 3471523111714
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
Let Us Find It
           or           
  • Description: AF38-30-22-11 24-60V50/60HZ 20-60VDC Contactor
  • Rated Control Circuit Voltage (Uc): 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
  • Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms
  • Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 1.5...10 mm² Flexible with Insulated Ferrule 2x 1.5...4 mm² Flexible with Ferrule 1/2x 1.5...10 mm² Rigid 1/2x 2.5...10 mm²
  • Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1...2.5 mm²
  • Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm²
  • Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 14 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
  • Terminal Type: Screw Terminals
  • Number of Main Contacts NO: 3
  • Climatic Withstand: Category B according to IEC 60947-1 Annex Q
  • Maximum Operating Altitude Permissible: 3000 m
  • Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 4 g closed position / 2 g open position
  • Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g
  • RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1
  • Ambient Air Temperature: Close to Contactor for Storage -60...+80 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C
  • General Use Rating UL/CSA: (600 V AC) 50 A
  • Horsepower Rating UL/CSA: (120 V AC) Single Phase 2 Hp (240 V AC) Single Phase 5 Hp (200 ... 208 V AC) Three Phase 10 Hp (220 ... 240 V AC) Three Phase 10 Hp (440 ... 480 V AC) Three Phase 25 Hp (550 ... 600 V AC) Three Phase 30 Hp
  • Tightening Torque UL/CSA: Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb Main Circuit 22 in·lb
  • Instructions and Manuals: 1SBC101027M6801
  • ABS Certificate: ABS_15-GE1349500-PDA_90682247
  • CB Certificate: CB_SE_70856M1
  • CCC Certificate: CCC_2010010304445623
  • cUL Certificate: UL_20091124-E312527-7-1
  • Data Sheet, Technical Information: 1SBC101418D0201
  • Declaration of Conformity - CE: 1SBD250000U1000
  • DNV Certificate: DNV-GL_E13871
  • EAC Certificate: EAC_RU C-FR ME77 B01010
  • GL Certificate: DNV-GL_E13871
  • GOST Certificate: GOST_POCCFR.ME77.B07175.pdf
  • LR Certificate: LRS_1300087E1
  • RINA Certificate: RINA_ELE084013XG
  • RMRS Certificate: RMRS_1400682124
  • RoHS Information: 1SBD251012E1000
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • Object Classification Code: Q
  • Extended Product Type: AF38-30-22-11
  • Product ID: 1SBL297001R1122
  • EAN: 3471523111714
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • EAN: 3471523111714
  • Product Net Depth: 119.5 mm
  • Product Net Height: 86 mm
  • Product Net Weight: 0.360 kg
  • Product Net Width: 45 mm
  • Package Level 1 Width: 87 mm
  • Package Level 1 Length: 121 mm
  • Package Level 1 Height: 47 mm
  • Package Level 1 Gross Weight: 0.36 kg
  • Package Level 1 EAN: 3471523111714
  • Package Level 2 Units: 36 piece
  • Package Level 2 Width: 250 mm
  • Package Level 2 Length: 300 mm
  • Package Level 2 Height: 315 mm
  • Package Level 3 Units: 864 piece
  • Package Level 1 Units: 1 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 2
  • Number of Auxiliary Contacts NC: 2
  • Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
  • Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
  • Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 A acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Current AC-1 (Ie): (690 V) 40 °C 50 A (690 V) 60 °C 42 A (690 V) 70 °C 37 A
  • Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 40 A (380 / 400 V) 60 °C 38 A (415 V) 60 °C 38 A (440 V) 60 °C 38 A (500 V) 60 °C 33 A (690 V) 60 °C 24 A
  • Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 11 kW (380 / 400 V) 18.5 kW (400 V) 18.5 kW (415 V) 18.5 kW (440 V) 22 kW (500 V) 22 kW (690 V) 22 kW
  • Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A for 0.1 s 140 A for 1 s 100 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour
  • Rated Operational Current DC-13 (Ie): (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (48 V) 2.8 A / 134 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W (72 V) 1 A / 72 W
  • Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
  • Rated Impulse Withstand Voltage (Uimp): 6 kV
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
Santa Clara Systems specialises in hard-to-find parts. Choose from our overstock inventory and save on 1SBL297001R1122 . Santa Clara Systems carries 35,866 items from ABB.
  • Side-Mounted Add-On Auxiliary Contact Blocks (Mechanically-Linked Auxiliary Contacts Compliant With Annex L Of Iec 60947-5-1 Including The &Quot;Mechanically Linked&Quot; Symbol On The Contactor Side. N.C. Mirror Contacts Compliant With Annex F Of Iec 60947-4-1) - Control Circuit: Ac Or Dc Operated - Accessories: A Wide Range Of Accessories Is Available. Note: 2-Stack Contactors Available In Some Countries: Please Consult Your Abb Representative. Af..-30-..-11 Not Suitable For A Direct Control By Plc-Output.
  • Af38 Contactors Are Used For Controlling Power Circuits Up To 690 V Ac And 220 V Dc. They Are Mainly Used For Controlling 3-Phase Motors
  • Non-Inductive Or Slightly Inductive Loads. Af... Contactors Include An Electronic Coil Interface Accepting A Wide Control Voltage Uc Min. ... Uc Max. Only Four Coils Cover Control Voltages Between 24...500 V 50/60 Hz Or 20...500 V Dc. Af Contactors Can Manage Large Control Voltage Variations. One Coil Can Be Used For Different Control Voltages Used Worldwide Without Any Coil Change. Af Contactors Have Built-In Surge Protection And Do Not Require Additional Surge Suppressors. The Af... Series 2-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles With A Non-Removable Front-Mounted 2 N.O. + 2 N.C. Auxiliary Contact Block
  • Alternates

    • AF38-30-22-11
    • AF38 30 22 11
    • AF38302211

    Common Types

    • 1SBL297001R112Z
    • 1SBL297001R11Z2
    • 1SBL297001R11ZZ
    • 1SBL297001R1I22
    • 1SBL297001R1I2Z
    • 1SBL297001R1IZ2
    • 1SBL297001R1IZZ
    • 1SBL297001R1L22
    • 1SBL297001R1L2Z
    • 1SBL297001R1LZ2
    • 1SBL297001R1LZZ
    • 1SBL297001RI122
    • 1SBL297001RI12Z
    • 1SBL297001RI1Z2
    • 1SBL297001RI1ZZ
    • 1SBL297001RII22
    • 1SBL297001RII2Z
    • 1SBL297001RIIZ2
    • 1SBL297001RIIZZ
    • 1SBL297001RIL22
    • 1SBL297001RIL2Z
    • 1SBL297001RILZ2
    • 1SBL297001RILZZ
    • 1SBL297001RL122
    • 1SBL297001RL12Z

    Appended Numbers

    • 1SBL297001R1122-A
    • 1SBL297001R1122-B
    • 1SBL297001R1122-C
    • 1SBL297001R1122-D
    • 1SBL297001R1122-E
    • 1SBL297001R1122-F
    • 1SBL297001R1122-G
    • 1SBL297001R1122-H
    • 1SBL297001R1122-I
    • 1SBL297001R1122-J
    • 1SBL297001R1122-K
    • 1SBL297001R1122-L
    • 1SBL297001R1122-M
    • 1SBL297001R1122-N
    • 1SBL297001R1122-O
    • 1SBL297001R1122-P
    • 1SBL297001R1122-Q
    • 1SBL297001R1122-R
    • 1SBL297001R1122-S
    • 1SBL297001R1122-T
    • 1SBL297001R1122-U
    • 1SBL297001R1122-V
    • 1SBL297001R1122-W
    • 1SBL297001R1122-X
    • 1SBL297001R1122-Y
    • 1SBL297001R1122-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier Domestic and International
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo