• ABB 1SFL637001R7122 AF750-30-22 250-500V 50/60Hz / 250-500V DC Contactor Product Image
  • Abb 1SFL637001R7122 Barcode

1SFL637001R7122

Product Summary:

  • Product ID: 1SFL637001R7122
  • EAN: 7320500310632
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • EAN: 7320500310632
Let Us Find It
           or           
  • Description: AF750-30-22 250-500V 50/60Hz / 250-500V DC Contactor
  • Mechanical Durability: 3 million
  • Maximum Mechanical Switching Frequency: 300 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? ? 70 °C) °C
  • Rated Control Circuit Voltage (Uc): 60 Hz 250 500 V 50 Hz 250 500 V DC Operation 250 500 V
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 985 V·A Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Pull-in at Max. Rated Control Circuit Voltage DC 910 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 985 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
  • Operate Time: Between Coil Energization and NO Contact Closing 50 ... 120 ms Between Coil De-energization and NO Contact Opening 53 ... 73 ms Between Coil De-energization and NC Contact Closing 50 ... 70 ms Between Coil Energization and NC Contact Opening 45 ... 115 ms
  • Connecting Capacity Main Circuit: Rigid Al-Cable 300 mm² Bar 52 mm Rigid Cu-Cable 300 mm²
  • Connecting Capacity Auxiliary Circuit: Solid 2x14 mm² Flexible with Insulated Ferrule 2x0.752.5 mm² Stranded 2x14 mm² Flexible 2x0.752.5 mm² Flexible with Ferrule 2x0.752.5 mm²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Terminal Type: Main Circuit: Bars
  • Number of Main Contacts NO: 3
  • Maximum Operating Altitude Permissible: 3000 m
  • Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 5 g Shock Direction: C2 5 g Shock Direction: C1 5 g Shock Direction: B2 5 g Shock Direction: B1 5 g
  • RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2009 Q2
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 °C Close to Contactor for Storage -40+70 °C
  • General Use Rating UL/CSA: (600 V AC) 900 A
  • Horsepower Rating UL/CSA: (208 V AC) Three Phase 250 Hp (440 ... 480 V AC) Three Phase 600 Hp (550 ... 600 V AC) Three Phase 700 Hp (220 ... 240 V AC) Three Phase 300 Hp (200 V AC) Three Phase 250 Hp
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V
  • Instructions and Manuals: 1SFC380023-en
  • BV Certificate: 11727/C0 BV
  • CB Certificate: SE-69481
  • CCC Certificate: CQC_2007010304256684
  • CSA Certificate: 306712-1
  • Data Sheet, Technical Information: 1SBC100122C0202
  • Declaration of Conformity - CE: 1SFA1-65
  • DNV Certificate: DNV_E-10966
  • GL Certificate: GL_42988-02HH
  • LOVAG Certificate: SE-0114206
  • LR Certificate: LR_13_20009
  • RINA Certificate: ELE060313XG/002
  • RoHS Information: 1SFC101034D0203
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
  • Extended Product Type: AF750-30-22 250-500V 50/60Hz / 250-500V DC
  • Product ID: 1SFL637001R7122
  • EAN: 7320500310632
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • EAN: 7320500310632
  • Product Net Depth: 242.0 mm
  • Product Net Height: 283.0 mm
  • Product Net Weight: 15.000 kg
  • Product Net Width: 210.0 mm
  • Package Level 1 Width: 290 mm
  • Package Level 1 Length: 270 mm
  • Package Level 1 Height: 350 mm
  • Package Level 1 Gross Weight: 15 kg
  • Package Level 1 EAN: 7320500310632
  • Package Level 1 Units: 1 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 2
  • Number of Auxiliary Contacts NC: 2
  • Rated Operational Voltage: Main Circuit 1000 V
  • Rated Frequency (f): Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1050 A
  • Rated Operational Current AC-1 (Ie): (690 V) 55 °C 875 A (690 V) 40 °C 1050 A (1000 V) 40 °C 1000 A (1000 V) 55 °C 875 A (690 V) 70 °C 720 A (1000 V) 70 °C 720 A
  • Rated Operational Current AC-3 (Ie): (1000 V) 55 °C 300 A (690 V) 55 °C 650 A (220 / 230 / 240 V) 55 °C 750 A (415 V) 55 °C 750 A (440 V) 55 °C 750 A (380 / 400 V) 55 °C 750 A (500 V) 55 °C 750 A
  • Rated Operational Power AC-3 (Pe): (500 V) 520 kW (690 V) 600 kW (220 / 230 / 240 V) 220 kW (380 / 400 V) 400 kW (440 V) 450 kW (415 V) 425 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Short-Circuit Protective Devices: gG Type Fuses 1000 A
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
  • Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 60 cycles per hour
  • Rated Operational Current DC-1 (Ie): (850 V) 3 Poles in Series, 40 °C 1050 A (600 V) 3 Poles in Series, 40 °C 1050 A (110 V) 1-Pole, 40 °C 1050 A (110 V) 2 Poles in Series, 40 °C 1050 A (220 V) 3 Poles in Series, 40 °C 1050 A
  • Rated Operational Current DC-3 (Ie): (850 V) 3 Poles in Series, 40 °C 1050 A (600 V) 3 Poles in Series, 40 °C 1050 A (110 V) 1-Pole, 40 °C 1050 A (110 V) 2 Poles in Series, 40 °C 1050 A (220 V) 3 Poles in Series, 40 °C 1050 A
  • Rated Operational Current DC-5 (Ie): (850 V) 3 Poles in Series, 40 °C 1050 A (600 V) 3 Poles in Series, 40 °C 1050 A (110 V) 1-Pole, 40 °C 1050 A (110 V) 2 Poles in Series, 40 °C 1050 A (220 V) 3 Poles in Series, 40 °C 1050 A
  • Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Santa Clara Systems specialises in hard-to-find parts. Choose from our overstock inventory and save on 1SFL637001R7122 . Santa Clara Systems carries 35,881 items from ABB.
  • Ac/Dc
  • A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
  • Isolation
  • By-Pass And Distribution Application Up To Max 1000 V. Operated With Wide Control Voltage Range 250-500 V
  • Alternates

    • AF750-30-22-71
    • AF750 30 22 71
    • AF750302271

    Common Types

    • 1SFL637001R712Z
    • 1SFL637001R71Z2
    • 1SFL637001R71ZZ
    • 1SFL637001R7I22
    • 1SFL637001R7I2Z
    • 1SFL637001R7IZ2
    • 1SFL637001R7IZZ
    • 1SFL637001R7L22
    • 1SFL637001R7L2Z
    • 1SFL637001R7LZ2
    • 1SFL637001R7LZZ
    • 1SFL63700IR7122
    • 1SFL63700IR712Z
    • 1SFL63700IR71Z2
    • 1SFL63700IR71ZZ
    • 1SFL63700IR7I22
    • 1SFL63700IR7I2Z
    • 1SFL63700IR7IZ2
    • 1SFL63700IR7IZZ
    • 1SFL63700IR7L22
    • 1SFL63700IR7L2Z
    • 1SFL63700IR7LZ2
    • 1SFL63700IR7LZZ
    • 1SFL63700LR7122
    • 1SFL63700LR712Z

    Appended Numbers

    • 1SFL637001R7122-A
    • 1SFL637001R7122-B
    • 1SFL637001R7122-C
    • 1SFL637001R7122-D
    • 1SFL637001R7122-E
    • 1SFL637001R7122-F
    • 1SFL637001R7122-G
    • 1SFL637001R7122-H
    • 1SFL637001R7122-I
    • 1SFL637001R7122-J
    • 1SFL637001R7122-K
    • 1SFL637001R7122-L
    • 1SFL637001R7122-M
    • 1SFL637001R7122-N
    • 1SFL637001R7122-O
    • 1SFL637001R7122-P
    • 1SFL637001R7122-Q
    • 1SFL637001R7122-R
    • 1SFL637001R7122-S
    • 1SFL637001R7122-T
    • 1SFL637001R7122-U
    • 1SFL637001R7122-V
    • 1SFL637001R7122-W
    • 1SFL637001R7122-X
    • 1SFL637001R7122-Y
    • 1SFL637001R7122-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier Domestic and International
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo