- Description: Electronic Overload Relay | E45DU-30
- Product ID: 1SAX211001R1101
- Extended Product Type: 1SAX211001R1101
- Product Net Weight: 0.35 kg
- Product Net Width: 45 mm
- Product Net Height: 97 mm
- Product Net Depth: 85.1 mm
- Degree of Protection: IP20
- Ambient Air Temperature: Operation -25 ... +70 C Operation Compensated -25 ... +70 C Storage -25 ... +70 C
- Standards: IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): Auxiliary Circuit 6 kV Main Circuit 6 kV
- Rated Insulation Voltage (U<sub>i</sub>): 690 V
- Number of Poles: 3
- Rated Frequency (f): Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz
- Suitable For: A26 A30 A40 AL26 AL30 AL40 TAL26 TAL30 TAL40
- eClass: 7.0 27371502
- Tightening Torque: Auxiliary Circuit 0.8 ... 1.2 N·m Main Circuit 2.3 ... 2.6 N·m
- Mounting Position: Position 1 to 6
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 1
- Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 2.5 ... 10 mm Flexible with Insulated Ferrule 1/2x 2.5 ... 10 mm Flexible 1/2x 2.5 ... 10 mm Rigid 1/2x 2.5 ... 16 mm
- Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
- Maximum Operating Altitude Permissible: 2000 m
- Tightening Torque UL/CSA: Auxiliary Circuit 7 in·lb Main Circuit 22 in·lb
- Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm Flexible 1/2x 0.75 ... 2.5 mm Rigid 1/2x 1 ... 4 mm
- Wire Stripping Length: Auxiliary Circuit 9 mm Main Circuit 13 mm
- Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 14-6 AWG Stranded 1/2x 14-6 AWG
- Ampere Rating UL/CSA: 30 A
- Number of Protected Poles: 3
- EAN: 4016779666602
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Package Level 1 Width: 101 mm
- Package Level 1 Height: 49.5 mm
- Package Level 1 Length: 89 mm
- Package Level 1 Gross Weight: 0.386 kg
- Package Level 2 Units: 50 piece
- Package Level 2 Width: 525 mm
- Package Level 2 Height: 189 mm
- Package Level 2 Length: 263 mm
- Package Level 2 Gross Weight: 19.863 kg
- Package Level 2 EAN: 4013614483318
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Auxiliary Circuit 600 V AC/DC Main Circuit 690 V AC
- Rated Operational Current (I<sub>e</sub>): 30 A
- Rated Operational Current AC-3 (I<sub>e</sub>): 30 A
- Conventional Free-air Thermal Current (I<sub>th</sub>): Auxiliary Circuit NC 6 A Auxiliary Circuit NO 6 A
- Rated Operational Current AC-15 (I<sub>e</sub>): (240 V) NC 3 A (240 V) NO 3 A (400 V) NC 1.1 A (400 V) NO 1.1 A (500 V) NC 0.72 A (500 V) NO 0.72 A
- Rated Operational Current DC-13 (I<sub>e</sub>): (125 V) NC 0.55 A (125 V) NO 0.5 A (24 V) NC 1.5 A (24 V) NO 1.5 A (250 V) NC 0.27 A (250 V) NO 0.27 A (60 V) NC 0.55 A (60 V) NO 0.55 A
- Pollution Degree: 3
- Recommended Screw Driver: Auxiliary Circuit Pozidriv 2 Main Circuit Pozidriv 2
- Setting Range: 9 ... 30 A
- Ambient Air Temperature Compensation: Yes
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Connecting Capacity Auxiliary Circuit UL/CSA: Flexible 1/2x 16-10 AWG Stranded 1/2x 16-10 AWG
- Data Sheet, Technical Information (Part 2): 1SAX100502F0002 1SAX100508F0001
- Instructions and Manuals: 2CDC107013M5501
- CB Certificate: 1SAA964003-2002
- CCC Certificate: 1SAA942002-3801
- cUL Certificate: cUL_E48139
- Data Sheet, Technical Information: 1SBC100173C0201
- Declaration of Conformity - CE: 1SAD938509-0053
- RMRS Certificate: 1SAA964000-0702
- RoHS Information: 1SAA964002-4401
- UL Certificate: UL_E48139
- E-nummer: 3228765
- ETIM 4: EC001080 - Electronic overload relay
- ETIM 5: EC001080 - Electronic overload relay
- ETIM 6: EC001080 - Electronic overload relay
- UNSPSC: 39121521
- Object Classification Code: F
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on E45DU-30 . Santa Clara Systems carries 36,687 items from ABB.
- 30e). Further Features Are The Temperature Compensation
- Trip Contact (Nc)
- Signal Contact (No)
- Automatic- Or Manual Reset Selectable
- Trip-Free Mechanism
- Stop- And Test Function And A Trip Indication. The Overload Relays Are Connected Directly To The Contactors. Single Mounting Kits Are Available As Accessory.
- The E45du-30 Is An Self-Supplied Electronic Overload Relay
- Which Means No Extra External Supply Is Needed. It Offers Reliable And Fast Protection For Motors In The Event Of Overload Or Phase Failure. Easy To Use Like A Thermal Overload Relay And Compatible With Standard Motor Applications
- The Electronic Overload Relay Is Convincing
- Above All
- Due To Its Wide Setting Range
- High Accuracy
- High Operational Temperature Range And The Possibility To Select A Trip Class (10e
- 20e
Alternates
- 1SAX211001R1101
- E45DU 30
- E45DU30
Common Typos
- E45DU-3O
- E4SDU-30
- E4SDU-3O
Appended Numbers
- E45DU-30-A
- E45DU-30-B
- E45DU-30-C
- E45DU-30-D
- E45DU-30-E
- E45DU-30-F
- E45DU-30-G
- E45DU-30-H
- E45DU-30-I
- E45DU-30-J
- E45DU-30-K
- E45DU-30-L
- E45DU-30-M
- E45DU-30-N
- E45DU-30-O
- E45DU-30-P
- E45DU-30-Q
- E45DU-30-R
- E45DU-30-S
- E45DU-30-T
- E45DU-30-U
- E45DU-30-V
- E45DU-30-W
- E45DU-30-X
- E45DU-30-Y
- E45DU-30-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier