- Description: Contactor Relay| NL44E-81
- Product ID: 1SBH143001R8144
- Extended Product Type: 1SBH143001R8144
- Product Net Weight: 0.580 kg
- Product Net Width: 44 mm
- Product Net Height: 78 mm
- Product Net Depth: 130 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Ambient Air Temperature: Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 C Near Contactor for Operation in Free Air (Uc) -40 ... +70 C Close to Contactor for Storage -60 ... +80 C
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
- Terminal Type: Screw Terminals
- Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
- Number of Auxiliary Contacts NO: 4
- Number of Auxiliary Contacts NC: 4
- Mechanical Durability: > 20 million
- GOST Certificate: GOST_POCCFRME77B07174
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): DC Operation 24 V
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Mechanical Switching Frequency: 6000 cycles per hour
- Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
- Operate Time: Between Coil Energization and NO Contact Closing 50 ... 100 ms Between Coil De-energization and NO Contact Opening 10 ... 17 ms Between Coil De-energization and NC Contact Closing 16 ... 27 ms Between Coil Energization and NC Contact Opening 20 ... 70 ms
- Country of Origin: France (FR)
- GL Certificate: GL_26306_05HH
- Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A
- Coil Consumption: Average Holding Value, from Warm State 3 W Average Pull-in Value, from Cold State 3 W
- Coil Operating Limits: (acc. to IEC 60947-5-1) 0.85 ... 1.1 x Uc (at 55 C) C
- Lead Time: 40 day(s)
- EAN: 3471522295811
- Criticality: No
- Made To Order: No
- Product Sales Status: Active
- Quote Only: No
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Package Level 1 Width: 86 mm
- Package Level 1 Length: 141 mm
- Package Level 1 Height: 51 mm
- Package Level 1 Gross Weight: 0.58 kg
- Package Level 1 EAN: 3471522295811
- Package Level 2 Units: 28 piece
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-5-1, q = 40 C 16 A
- Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I<sub>cw</sub>): for 0.1 s 140 A for 1 s 100 A
- Maximum Electrical Switching Frequency: 1200 cycles per hour
- Rated Operational Current DC-13 (I<sub>e</sub>): (125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: A 20 g Open, Shock Direction: A 10 g Closed, Shock Direction: B1 15 g Open, Shock Direction: B1 5 g Shock Direction: B2 10 g Closed, Shock Direction: C1 20 g Open, Shock Direction: C1 8 g Closed, Shock Direction: C2 14 g Open, Shock Direction: C2 8 g
- RoHS Status: Following EU Directive 2011/65/EC
- Instructions and Manuals: 1SBC101003M5501
- CB Certificate: CB_SE_66833A1
- CCC Certificate: CCC_2012010304558126
- CSA Certificate: CSA_1041746
- cUL Certificate: UL_110105E48139A
- Data Sheet, Technical Information: 1SBC100122C0202_Ch03
- Declaration of Conformity - CE: 1SBD250808U1000
- RoHS Information: 1SBD350057R1001
- UL Certificate: UL_110105E48139A
- ETIM 4: EC000196 - Contactor relay
- ETIM 5: EC000196 - Contactor relay
- ETIM 6: EC000196 - Contactor relay
- UNSPSC: 39121500
- Object Classification Code: K
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on NL44E-81 . Santa Clara Systems carries 36,687 items from ABB.
- Nl... Contactor Relays Are Used For Switching Auxiliary Circuits And Control Circuits - Poles: 8-Pole Contactor Relays (Mechanically Linked Contact Elements Available) The Width Of 8-Pole Devices Is Identical To That Of 4-Pole Devices Only The Depth Is Increased - Control Circuit: Dc Operated With Solid Core Magnet Circuit. The Polarity On The Coil Terminals (A1+ And A2-) Must Be Respected - Accessories: A Wide Range Of Accessories Is Available Nl... Contactors Are Fitted With Low Consumption Dc Coils And Are Suitable For A Direct Control By Plc Outputs. <Br /> Only The Depth Is Increased<Br/>- Control Circuit: Dc Operated With Solid Core Magnet Circuit. The Polarity On The Coil Terminals (A1+ And A2-) Must Be Respected<Br/>- Accessories: A Wide Range Of Accessories Is Available<Br/>nl... Contactors Are Fitted With Low Consumption Dc Coils And Are Suitable For A Direct Control By Plc Outputs.
Alternates
- 1SBH143001R8144
- NL44E 81
- NL44E81
Common Typos
- N144E-81
- N144E-8I
- N144E-8L
- N144E-B1
- N144E-BI
- N144E-BL
- NI44E-81
- NI44E-8I
- NI44E-8L
- NI44E-B1
- NI44E-BI
- NI44E-BL
- NL44E-8I
- NL44E-8L
- NL44E-B1
- NL44E-BI
- NL44E-BL
Appended Numbers
- NL44E-81-A
- NL44E-81-B
- NL44E-81-C
- NL44E-81-D
- NL44E-81-E
- NL44E-81-F
- NL44E-81-G
- NL44E-81-H
- NL44E-81-I
- NL44E-81-J
- NL44E-81-K
- NL44E-81-L
- NL44E-81-M
- NL44E-81-N
- NL44E-81-O
- NL44E-81-P
- NL44E-81-Q
- NL44E-81-R
- NL44E-81-S
- NL44E-81-T
- NL44E-81-U
- NL44E-81-V
- NL44E-81-W
- NL44E-81-X
- NL44E-81-Y
- NL44E-81-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier