- Description: S751/3-E16 sel. main CB E-Char.,25kA,16A,3x1P
- Product ID: 2CDS781001R4162
- Extended Product Type: 2CDS781001R4162
- Product Net Weight: 1.17 kg
- Product Net Width: 81 mm
- Product Net Height: 151.3 mm
- Product Net Depth: 116 mm
- Degree of Protection: IP20
- Ambient Air Temperature: Operation -25 ... +55 C Storage -40 ... +70 C
- Standards: DIN VDE 0641-21
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 6 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC/EN 60664-1 690 V
- Number of Poles: 3
- Terminal Type: Screwless Terminals
- Rated Current (I<sub>n</sub>): 16 A
- Function: Single Pole Switching
- Rated Frequency (f): 50 Hz 60 Hz
- Mounting on DIN Rail: No
- eClass: 7.0 27141903
- Tightening Torque: 2.5 ... 3 N·m
- Mounting Position: Any
- Tripping Characteristic: E (Selective)
- Connecting Capacity: Flexible with Ferrule 2.5 ... 50 mm Flexible 2.5 ... 16 mm
- Contact Position Indication: Red ON / Green OFF
- Overvoltage Category: IV
- Environmental Conditions: 28 cycles with 55 C / 90-96 % and 25 C / 95-100 %
- Dielectric Test Voltage: 50 / 60 Hz, 1 min: 2 kV
- EAN: 4016779660525
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362010
- Package Level 1 Width: 95 mm
- Package Level 1 Length: 186 mm
- Package Level 1 Height: 145 mm
- Package Level 1 Gross Weight: 1.3 kg
- Package Level 1 EAN: 4016779668163
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: 230 / 400 V AC
- Rated Short-Circuit Capacity (I<sub>cn</sub>): 25 kA
- Pollution Degree: 3
- Remarks: IP40 in enclosure with cover
- Recommended Screw Driver: Cross Recess Pozidriv 2 Slotted 1 x 5.5
- Power Supply Connection: Arbitrary
- Resistance to Shock acc. to IEC 60068-2-27: 30g / 3 shocks / 11 ms
- Resistance to Vibrations acc. to IEC 60068-2-6: 2g, 20 cycles at 5 ... 150 ... 5Hz
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: 2CDC415012D0202 2CDC415012D0102
- Data Sheet, Technical Information: 2CDC415012D0202 2CDC415012D0102
- Declaration of Conformity - CE: 2CDK415031D2702
- RoHS Information: 2CDK415005D0201
- ETIM 4: EC001047 - Selective main line circuit breaker
- ETIM 5: EC001047 - Selective main line circuit breaker
- ETIM 6: EC001047 - Selective main line circuit breaker
- Object Classification Code: F
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on S751-3-E16 . Santa Clara Systems carries 36,687 items from ABB.
- 3x1p
- S751/3-E16 Sel. Main Cb E-Char.
- 25ka
- 16a
Alternates
- 2CDS781001R4162
- S751/3 E16
- S751/3E16
- S7513E16
Common Typos
- S751-3-E1G
- S751-3-EI6
- S751-3-EIG
- S751-3-EL6
- S751-3-ELG
- S75I-3-E16
- S75I-3-E1G
- S75I-3-EI6
- S75I-3-EIG
- S75I-3-EL6
- S75I-3-ELG
- S75L-3-E16
- S75L-3-E1G
- S75L-3-EI6
- S75L-3-EIG
- S75L-3-EL6
- S75L-3-ELG
- S7S1-3-E16
- S7S1-3-E1G
- S7S1-3-EI6
- S7S1-3-EIG
- S7S1-3-EL6
- S7S1-3-ELG
- S7SI-3-E16
- S7SI-3-E1G
- S7SI-3-EI6
Appended Numbers
- S751-3-E16-A
- S751-3-E16-B
- S751-3-E16-C
- S751-3-E16-D
- S751-3-E16-E
- S751-3-E16-F
- S751-3-E16-G
- S751-3-E16-H
- S751-3-E16-I
- S751-3-E16-J
- S751-3-E16-K
- S751-3-E16-L
- S751-3-E16-M
- S751-3-E16-N
- S751-3-E16-O
- S751-3-E16-P
- S751-3-E16-Q
- S751-3-E16-R
- S751-3-E16-S
- S751-3-E16-T
- S751-3-E16-U
- S751-3-E16-V
- S751-3-E16-W
- S751-3-E16-X
- S751-3-E16-Y
- S751-3-E16-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier