- Description: Contactor | 1SFL487002R1111
- Product ID: 1SFL487002R1111
- Extended Product Type: 1SFL487002R1111
- Product Net Weight: 2.778 kg
- Product Net Width: 105.0 mm
- Product Net Height: 196.0 mm
- Product Net Depth: 152.0 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C Close to Contactor for Storage -40…+70 °C
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Terminal Type: Main Circuit: Bars
- Rated Frequency (f): Main Circuit 50/60 Hz
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 1
- Mechanical Durability: 5 million
- Connecting Capacity Main Circuit: Rigid Al-Cable 1x95…185 mm² Flexible 2x50…95 mm² Rigid Cu-Cable 2x50…120 mm²
- Maximum Operating Voltage UL/CSA: Main Circuit 600 V
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): 60 Hz 24…60 V 50 Hz 24…60 V DC Operation 20…60 V
- Maximum Mechanical Switching Frequency: 300 cycles per hour
- Connecting Capacity Auxiliary Circuit: Solid 2x1…4 mm² Flexible with Insulated Ferrule 2x0.75…2.5 mm² Stranded 2x1…4 mm² Flexible 2x0.75…2.5 mm² Flexible with Ferrule 2x0.75…2.5 mm²
- Operate Time: Between Coil Energization and NO Contact Closing 25…55 ms Between Coil De-energization and NO Contact Opening 37…47 ms
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Short-Circuit Protective Devices: gG Type Fuses 355 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2200 A
- Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 165 V·A Holding at Max. Rated Control Circuit Voltage DC 2.5 W Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A Pull-in at Max. Rated Control Circuit Voltage DC 205 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 165 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
- Horsepower Rating UL/CSA: (208 V AC) Three Phase 50 Hp (440 ... 480 V AC) Three Phase 125 Hp (550 ... 600 V AC) Three Phase 150 Hp (220 ... 240 V AC) Three Phase 60 Hp (200 V AC) Three Phase 50 Hp
- General Use Rating UL/CSA: (600 V AC) 250 A
- EAN: 7320500480410
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Package Level 1 Width: 223 mm
- Package Level 1 Length: 133 mm
- Package Level 1 Height: 186 mm
- Package Level 1 Gross Weight: 3.228 kg
- Package Level 1 EAN: 7320500480410
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Main Circuit 1000 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 275 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 55 °C 250 A (690 V) 40 °C 275 A (1000 V) 40 °C 250 A (1000 V) 55 °C 225 A (690 V) 70 °C 200 A (1000 V) 70 °C 185 A
- Rated Operational Current AC-3 (I<sub>e</sub>): (1000 V) 55 °C 85 A (415 V) 55 °C 190 A (690 V) 55 °C 135 A (220 / 230 / 240 V) 55 °C 190 A (440 V) 55 °C 190 A (380 / 400 V) 55 °C 190 A (500 V) 55 °C 135 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (500 V) 90 kW (1000 V) 110 kW (220 / 230 / 240 V) 55 kW (690 V) 132 kW (380 / 400 V) 90 kW (440 V) 110 kW (415 V) 90 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 A
- Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour
- Rated Operational Current DC-1 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 40 °C 250 A
- Rated Operational Current DC-3 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 40 °C 250 A
- Rated Operational Current DC-5 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 40 °C 250 A
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: 1SFC100008M0201
- CB Certificate: SE-71797M1
- Data Sheet, Technical Information: 1SFC101070D0201
- Declaration of Conformity - CE: 2CMT004613
- RINA Certificate: ELE060313XG/002
- RoHS Information: 1SFC101055D0202
- E-nummer: 3210132
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- UNSPSC: 39121529
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AF190-30-11-11 . Santa Clara Systems carries 37,005 items from ABB.
- 50 And 60 Hz
- 20-60 V Dc
- A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
- Isolation
- By-Pass And Distribution Application Up To Max 1000 V. Operated With Wide Control Voltage Range 24-60 V
Alternates
- 1SFL487002R1111
- AF190 30 11 11
- AF190301111
Common Typos
- AF190-30-11-1I
- AF190-30-11-1L
- AF190-30-11-I1
- AF190-30-11-II
- AF190-30-11-IL
- AF190-30-11-L1
- AF190-30-11-LI
- AF190-30-11-LL
- AF190-30-1I-11
- AF190-30-1I-1I
- AF190-30-1I-1L
- AF190-30-1I-I1
- AF190-30-1I-II
- AF190-30-1I-IL
- AF190-30-1I-L1
- AF190-30-1I-LI
- AF190-30-1I-LL
- AF190-30-1L-11
- AF190-30-1L-1I
- AF190-30-1L-1L
- AF190-30-1L-I1
- AF190-30-1L-II
- AF190-30-1L-IL
- AF190-30-1L-L1
- AF190-30-1L-LI
- AF190-30-1L-LL
Appended Numbers
- AF190-30-11-11-A
- AF190-30-11-11-B
- AF190-30-11-11-C
- AF190-30-11-11-D
- AF190-30-11-11-E
- AF190-30-11-11-F
- AF190-30-11-11-G
- AF190-30-11-11-H
- AF190-30-11-11-I
- AF190-30-11-11-J
- AF190-30-11-11-K
- AF190-30-11-11-L
- AF190-30-11-11-M
- AF190-30-11-11-N
- AF190-30-11-11-O
- AF190-30-11-11-P
- AF190-30-11-11-Q
- AF190-30-11-11-R
- AF190-30-11-11-S
- AF190-30-11-11-T
- AF190-30-11-11-U
- AF190-30-11-11-V
- AF190-30-11-11-W
- AF190-30-11-11-X
- AF190-30-11-11-Y
- AF190-30-11-11-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier