- Description: CM-SRS.M1S Current monitoring relay 2c/o, B-C=3mA-1A RMS, 24-240VAC/DC
- Product ID: 1SVR730840R0600
- Extended Product Type: 1SVR730840R0600
- Product Net Weight: 0.153 kg
- Product Net Width: 22.5 mm
- Product Net Height: 85.6 mm
- Product Net Depth: 103.7 mm
- Degree of Protection: Housing IP50 Terminals IP20
- Ambient Air Temperature: Operation -20 ... +60 °C Storage -40 ... +85 °C
- Standards: EN 50178 IEC/EN 60255-27 IEC/EN 61000-6-2 IEC/EN 61000-6-3 UL 508 CAN/CSA C22.2 No.14
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): Measuring Circuit / Output Circuit 6 kV Output Circuit 1 / Output Circuit 2 4 kV Supply Circuit / Measuring Circuit 6 kV Supply Circuit / Output Circuit 4 kV
- Rated Insulation Voltage (U<sub>i</sub>): Measuring Circuit / Output Circuit 600 V Output Circuit 1 / Output Circuit 2 250 V Supply Circuit / Measuring Circuit 600 V Supply Circuit / Output Circuit 250 V
- Terminal Type: Screw Terminals
- Function: Over- or undercurrent monitoring
- Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- eClass: 7.0 27371802
- Tightening Torque: 0.6 ... 0.8 N·m
- Mounting Position: Any
- Mechanical Durability: 30000000 cycle
- Connecting Capacity: Flexible with Ferrule 1x 0.5 ... 2.5 mm² Flexible with Ferrule 2x 0.5 ... 1.5 mm² Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² Flexible 1x 0.5 ... 2.5 mm² Flexible 2x 0.5 ... 1.5 mm² Rigid 1x 0.5 ... 4 mm² Rigid 2x 0.5 ... 2.5 mm²
- Maximum Operating Voltage UL/CSA: Output Circuit 300 V AC
- Tightening Torque UL/CSA: 7.08 in·lb
- Overvoltage Category: III
- Connecting Capacity UL/CSA: Flexible 1x 18-14 AWG Flexible 2x 18-16 AWG Rigid 1x 20-12 AWG Rigid 2x 20-14 AWG
- Wire Stripping Length: 8 mm
- GL Certificate: GL_61766-14HH
- Short-Circuit Protective Devices: Output Circuit NC - F Type Fuses 10 A Output Circuit NO - F Type Fuses 10 A
- Rated Control Supply Voltage (U<sub>s</sub>): 24 ... 240 V AC/DC
- Output: 2 c/o (SPDT) contacts; operating principle selectable
- Electrical Durability: AC-12 100000 cycle
- EAN: 4016779852265
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Package Level 1 Width: 97 mm
- Package Level 1 Height: 109 mm
- Package Level 1 Length: 30 mm
- Package Level 1 Gross Weight: 0.175 kg
- Package Level 1 Units: 1 piece
- Measuring Range: 3 ... 30 mA 10 ... 100 mA 0.1 ... 1 A
- Time Range: 0 s or 0.1-30 s start-up delay 0 s or 0.1-30 s tripping delay (ON)
- Rated Operational Current AC-12 (I<sub>e</sub>): (230 V) 4 A
- Rated Operational Current AC-15 (I<sub>e</sub>): (230 V) 3 A
- Rated Operational Current DC-12 (I<sub>e</sub>): (24 V) 4 A
- Rated Operational Current DC-13 (I<sub>e</sub>): (24 V) 2 A
- Minimum Switching Capacity: 24 V 10 mA
- Pollution Degree: 3
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Contact Rating UL/CSA: B300
- Instructions and Manuals: 1SVC730620M0000
- CB Certificate: CB_DK-28255-UL
- CCC Certificate: CCC_2007010303243843.pdf
- cULus Certificate: cULus508_20120203-E140448
- Data Sheet, Technical Information: 2CDC112169D0201
- Declaration of Conformity - CE: 1SVD981013-0000
- EAC Certificate: EAC_RU_C-DE.ME77.B.01012
- RMRS Certificate: RMRS_12.04009.250
- RoHS Information: 1SAA981056-4401
- E-nummer: 3860629
- ETIM 4: EC001440 - Current monitoring relay
- ETIM 5: EC001440 - Current monitoring relay
- ETIM 6: EC001440 - Current monitoring relay
- Object Classification Code: B
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on CM-SRS.M1S . Santa Clara Systems carries 37,000 items from ABB.
- With Or Without Latching Function. The Hysteresis Is Adjustable Within A Range Of 3 To 30 % Of The Threshold Value. The Tripping Delay And The Start-Up Delay Are Adjustable Over A Range Of Instantaneous To 30 S (0
- 0.1-30 S). A Sealable Transparent Cover For Protection Against Unauthorized Changes Is Available As Accessory. The Device Offers Screw Connection Technology With Double-Chamber Cage Connection Terminals.
- The Cm-Srs.m1s Is A Multifunctional Current Monitoring Relay From The Cm Single-Phase Monitors Range. This Monitoring Relay Operates With A Rated Control Supply Voltage Of 24 - 240 V Ac / Dc And Has A 2 C/o (Spdt) Output With Contacts Rated At 250 V / 4 A. It Provides A Rms Measuring Principle For Dc And Ac Currents With 3 Measuring Ranges: 3-30 Ma
- 10-100 Ma And 0.1-1 A. The Cm-Srs.m1s Offers Selection Of Over- Or Undercurrent Monitoring
- Open- Or Closed-Circuit Operating Principle
Alternates
- 1SVR730840R0600
- CM SRS.M1S
- CMSRS.M1S
- CMSRSM1S
Common Typos
- CM-5R5.M15
- CM-5R5.M1S
- CM-5R5.MI5
- CM-5R5.MIS
- CM-5R5.ML5
- CM-5R5.MLS
- CM-5RS.M15
- CM-5RS.M1S
- CM-5RS.MI5
- CM-5RS.MIS
- CM-5RS.ML5
- CM-5RS.MLS
- CM-SR5.M15
- CM-SR5.M1S
- CM-SR5.MI5
- CM-SR5.MIS
- CM-SR5.ML5
- CM-SR5.MLS
- CM-SRS.M15
- CM-SRS.MI5
- CM-SRS.MIS
- CM-SRS.ML5
- CM-SRS.MLS
Appended Numbers
- CM-SRS.M1S-A
- CM-SRS.M1S-B
- CM-SRS.M1S-C
- CM-SRS.M1S-D
- CM-SRS.M1S-E
- CM-SRS.M1S-F
- CM-SRS.M1S-G
- CM-SRS.M1S-H
- CM-SRS.M1S-I
- CM-SRS.M1S-J
- CM-SRS.M1S-K
- CM-SRS.M1S-L
- CM-SRS.M1S-M
- CM-SRS.M1S-N
- CM-SRS.M1S-O
- CM-SRS.M1S-P
- CM-SRS.M1S-Q
- CM-SRS.M1S-R
- CM-SRS.M1S-S
- CM-SRS.M1S-T
- CM-SRS.M1S-U
- CM-SRS.M1S-V
- CM-SRS.M1S-W
- CM-SRS.M1S-X
- CM-SRS.M1S-Y
- CM-SRS.M1S-Z
More Products Like This
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier