- Description: Miniature Circuit Breaker | 2CDS251001R0034
- Product ID: 2CDS251001R0034
- Extended Product Type: 2CDS251001R0034
- Product Net Weight: 0.125 kg
- Product Net Width: 17.5 mm
- Product Net Height: 88 mm
- Product Net Depth: 69 mm
- Degree of Protection: IP20
- Ambient Air Temperature: Operation -25 ... +55 °C Storage -40 ... +70 °C
- Standards: IEC/EN 60898-1 IEC/EN 60947-2 UL 1077
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 4 kV (6.2 kV @ sea level) (5.0 kV @ 2000 m)
- Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC/EN 60664-1 440 V
- Number of Poles: 1
- Terminal Type: Screw Terminals
- Rated Current (I<sub>n</sub>): 3 A
- Rated Frequency (f): 50 Hz 60 Hz
- Power Loss: 1.3 W at Rated Operating Conditions per Pole 1.3 W
- Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- eClass: 7.0 27141901
- Tightening Torque: 2.8 N·m
- Actuator Type: Insulation group II, black, sealable
- Mounting Position: Any
- Tripping Characteristic: C
- Connecting Capacity: Busbar 10 / 10 mm² Flexible with Ferrule 0.75 ... 25 mm² Flexible 0.75 ... 25 mm² Rigid 0.75 ... 35 mm² Stranded 0.75 ... 35 mm²
- Maximum Operating Voltage UL/CSA: 277 V AC
- Contact Position Indication: Red ON / Green OFF
- Tightening Torque UL/CSA: 25 in·lb
- Overvoltage Category: III
- Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
- Housing Material: Insulation Group II, RAL 7035
- Electrical Endurance: 20000 AC cycle
- Mechanical Endurance: 20000 cycle
- Connecting Capacity UL/CSA: Busbar 18-8 AWG Conductor 18-4 AWG
- Operational Voltage: Maximum (Incl. Tolerance) 253 V AC Maximum (Incl. Tolerance) 72 V DC Minimum 12 V AC / 12 V DC
- Dielectric Test Voltage: 50 / 60 Hz, 1 min: 2 kV
- Energy Limiting Class: 3
- Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal
- Interrupting Rating acc. to UL1077: 6 kA (DC) 10 kA
- EAN: 4016779523332
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362010
- Package Level 1 Width: 92 mm
- Package Level 1 Length: 183 mm
- Package Level 1 Height: 80 mm
- Package Level 1 Gross Weight: 1.295 kg
- Package Level 1 EAN: 4016779606714
- Package Level 2 Units: 120 piece
- Package Level 2 Width: 275 mm
- Package Level 2 Length: 395 mm
- Package Level 2 Height: 210 mm
- Package Level 2 Gross Weight: 14.8 kg
- Package Level 2 EAN: 4016779970549
- Package Level 1 Units: 10 piece
- Resistance to Shock acc. to IEC 60068-2-27: 25g / 2 shocks / 13 ms
- Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Rated Operational Voltage: acc. to IEC 60898-1 230 / 400 V AC acc. to IEC 60947-2 230 V AC
- Rated Short-Circuit Capacity (I<sub>cn</sub>): (AC) 6 kA 6 kA (DC) kA
- Rated Ultimate Short-Circuit Breaking Capacity (I<sub>cu</sub>): 10 kA 10 kA (DC) kA
- Rated Service Short-Circuit Breaking Capacity (I<sub>cs</sub>): 7.5 kA
- Pollution Degree: 3
- Remarks: IP40 in enclosure with cover
- Recommended Screw Driver: Pozidriv 2
- Instructions and Manuals: 2CSC400002D0208
- Data Sheet, Technical Information: 2CSC400002D0208
- Declaration of Conformity - CE: 2CDK403001D0604
- RoHS Information: 2CDK400003K0201
- E-nummer: 2100505
- ETIM 4: EC000042 - Miniature circuit breaker (MCB)
- ETIM 5: EC000042 - Miniature circuit breaker (MCB)
- ETIM 6: EC000042 - Miniature circuit breaker (MCB)
- UNSPSC: 39121614
- Object Classification Code: F
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on S201-C3 . Santa Clara Systems carries 36,972 items from ABB.
- 3p
- 3p+n
- 4p)
- Breaking Capacities (Up To 6 Ka At 230/400 V Ac) And Rated Currents (Up To 63a). All Mcbs Of The Product Range S200 Comply With Iec/en 60898-1
- Iec/en 60947-2
- Ul1077 And Csa 22.2 No. 235
- Allowing The Use For Residential
- Commercial And Industrial Applications. Bottom-Fitting Auxiliary Contact Can Be Mounted On S200 To Save 50% Space.
- System Pro M Compact S200 Miniature Circuit Breakers Are Current Limiting. They Have Two Different Tripping Mechanisms
- The Delayed Thermal Tripping Mechanism For Overload Protection And The Electromechanic Tripping Mechanism For Short Circuit Protection. They Are Available In Different Characteristics (B
- C
- D
- K
- Z)
- Configurations (1p
- 1p+n
- 2p
Alternates
- 2CDS251001R0034
- S201 C3
- S201C3
- S523332
Common Typos
- 5201-C3
- 520I-C3
- 520L-C3
- 52O1-C3
- 52OI-C3
- 52OL-C3
- 5Z01-C3
- 5Z0I-C3
- 5Z0L-C3
- 5ZO1-C3
- 5ZOI-C3
- 5ZOL-C3
- S20I-C3
- S20L-C3
- S2O1-C3
- S2OI-C3
- S2OL-C3
- SZ01-C3
- SZ0I-C3
- SZ0L-C3
- SZO1-C3
- SZOI-C3
- SZOL-C3
Appended Numbers
- S201-C3-A
- S201-C3-B
- S201-C3-C
- S201-C3-D
- S201-C3-E
- S201-C3-F
- S201-C3-G
- S201-C3-H
- S201-C3-I
- S201-C3-J
- S201-C3-K
- S201-C3-L
- S201-C3-M
- S201-C3-N
- S201-C3-O
- S201-C3-P
- S201-C3-Q
- S201-C3-R
- S201-C3-S
- S201-C3-T
- S201-C3-U
- S201-C3-V
- S201-C3-W
- S201-C3-X
- S201-C3-Y
- S201-C3-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier