- Description: TeSys K - Auxiliary contact block - 2 NO + 2 NC - screw-clamps terminals
- Product weight: 0.1 lb(US) (0.045 kg)
- Range of product: TeSys K control relayTeSys K
- IP degree of protection: IP2x conforming to VDE 0106
- Standards: BS 5424IEC 60947VDE 0660NF C 63-110
- Device short name: LA1
- Depth: 1.38 in (35 mm)
- Protective treatment: TC conforming to IEC 60068
- [Ui] rated insulation voltage: 600 V - for control circuit - conforming to CSA C22.2690 V - for control circuit - conforming to BS 5424690 V - for control circuit - conforming to IEC 60947750 V - for control circuit - conforming to VDE 0010 group C
- Operating altitude: 6561.68 ft. (2000 m) without derating in temperature
- Tightening torque: 11.5 lbf.in (1.3 N.m) - on screw clamp terminals - with screwdriver Philips No 2
- Connections - terminals: Screw clamp terminals 1 cable 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable endScrew clamp terminals 2 cable 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable endScrew clamp terminals 1 cable 0...0.01 in² (0.75...4 mm²) - cable stiffness: flexible - without cable endScrew clamp terminals 2 cable 0...0.01 in² (0.75...4 mm²) - cable stiffness: flexible - without cable endScrew clamp terminals 1 cable 0...0.01 in² (1.5...4 mm²) - cable stiffness: solidScrew clamp terminals 2 cable 0...0.01 in² (1.5...4 mm²) - cable stiffness: solid
- Range: TeSys
- [Ith] conventional free air thermal current: 10 A at <= 122 °F (50 °C)
- System Voltage: <= 690 V AC <= 400 Hz
- Insulation resistance: > 10 MOhm control circuit
- Associated fuse rating: 10 A gG <= 690 V IEC 6094710 A gG <= 690 V VDE 0660
- Mounting location: Front
- Environmental characteristic: Normal environment
- Product certifications: CSAUL
- Product or component type: Auxiliary contact block
- Auxiliary contacts operation: Instantaneous
- Irms rated making capacity: 110 A at <= 690 V AC conforming to IEC 60947
- Pole contact composition: 2 NO + 2 NC
- Permissible short-time rating: 80 A 1 s60 A 500 ms110 A 100 ms
- Ambient air temperature for operation: -13...122 °F (-25...50 °C)
- Ambient air temperature for storage: -58...176 °F (-50...80 °C)
- Minimum switching current: 5 mA
- Minimum switching voltage: 17 V
- Non overlap distance: 0.02 in (0.5 mm)
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LA1KN22 . Santa Clara Systems carries 10,454 items from Telemecanique.
- Tesys K - Auxiliary Contact Block - 2 No + 2 Nc - Screw-Clamps Terminals
Alternates
Common Typos
- 1A1KN22
- 1A1KN2Z
- 1A1KNZ2
- 1A1KNZZ
- 1AIKN22
- 1AIKN2Z
- 1AIKNZ2
- 1AIKNZZ
- 1ALKN22
- 1ALKN2Z
- 1ALKNZ2
- 1ALKNZZ
- IA1KN22
- IA1KN2Z
- IA1KNZ2
- LA1KN2Z
- LA1KNZ2
- LA1KNZZ
- LAIKN22
- LAIKN2Z
- LAIKNZ2
- LAIKNZZ
- LALKN22
- LALKN2Z
- LALKNZ2
- LALKNZZ
Appended Numbers
- LA1KN22-A
- LA1KN22-B
- LA1KN22-C
- LA1KN22-D
- LA1KN22-E
- LA1KN22-F
- LA1KN22-G
- LA1KN22-H
- LA1KN22-I
- LA1KN22-J
- LA1KN22-K
- LA1KN22-L
- LA1KN22-M
- LA1KN22-N
- LA1KN22-O
- LA1KN22-P
- LA1KN22-Q
- LA1KN22-R
- LA1KN22-S
- LA1KN22-T
- LA1KN22-U
- LA1KN22-V
- LA1KN22-W
- LA1KN22-X
- LA1KN22-Y
- LA1KN22-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier