  • Description: AF750-30-22 24-60V DC Contactor
  • Product ID: 1SFL637001R6822
  • Extended Product Type: 1SFL637001R6822
  • Product Net Weight: 15.000 kg
  • Product Net Width: 210.0 mm
  • Product Net Height: 283.0 mm
  • Product Net Depth: 242.0 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 C Close to Contactor for Storage -40+70 C
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 8 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Terminal Type: Main Circuit: Bars
  • Rated Frequency (f): Main Circuit 60 Hz Main Circuit 50 Hz
  • Number of Auxiliary Contacts NO: 2
  • Number of Auxiliary Contacts NC: 2
  • Mechanical Durability: 3 million
  • Connecting Capacity Main Circuit: Rigid Al-Cable 300 mm Bar 52 mm Rigid Cu-Cable 300 mm
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): DC Operation 24 60 V
  • Maximum Mechanical Switching Frequency: 300 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Solid 2x14 mm Flexible with Insulated Ferrule 2x0.752.5 mm Stranded 2x14 mm Flexible 1x0.752.5 mm Flexible with Ferrule 2x0.752.5 mm
  • Operate Time: Between Coil Energization and NO Contact Closing 50 ... 120 ms Between Coil De-energization and NO Contact Opening 53 ... 73 ms Between Coil De-energization and NC Contact Closing 50 ... 70 ms Between Coil Energization and NC Contact Opening 45 ... 115 ms
  • Number of Main Contacts NO: 3
  • GL Certificate: GL_42988-02HH
  • Number of Main Contacts NC: 0
  • Short-Circuit Protective Devices: gG Type Fuses 1000 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 7500 A cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 690 V 7000 A
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 780 V&#183;A Holding at Max. Rated Control Circuit Voltage DC 5.5 V&#183;A Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V&#183;A Pull-in at Max. Rated Control Circuit Voltage DC 785 V&#183;A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 780 V&#183;A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V&#183;A
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at 70 C) C
  • Horsepower Rating UL/CSA: (208 V AC) Three Phase 250 Hp (440 ... 480 V AC) Three Phase 600 Hp (550 ... 600 V AC) Three Phase 700 Hp (220 ... 240 V AC) Three Phase 300 Hp (200 V AC) Three Phase 250 Hp
  • General Use Rating UL/CSA: (600 V AC) 900 A
  • EAN: 7320500222058
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • Package Level 1 Width: 290 mm
  • Package Level 1 Length: 270 mm
  • Package Level 1 Height: 350 mm
  • Package Level 1 Gross Weight: 15 kg
  • Package Level 1 EAN: 7320500222058
  • Package Level 1 Units: 1 piece
  • Rated Operational Voltage: Main Circuit 1000 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 1050 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 55 C 875 A (690 V) 40 C 1050 A (1000 V) 40 C 1000 A (1000 V) 55 C 875 A (690 V) 70 C 720 A (1000 V) 70 C 720 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (1000 V) 55 C 300 A (690 V) 55 C 650 A (220 / 230 / 240 V) 55 C 750 A (415 V) 55 C 750 A (440 V) 55 C 750 A (380 / 400 V) 55 C 750 A (500 V) 55 C 750 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (500 V) 520 kW (220 / 230 / 240 V) 220 kW (690 V) 600 kW (380 / 400 V) 400 kW (440 V) 450 kW (415 V) 425 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A
  • Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 60 cycles per hour
  • Rated Operational Current DC-1 (I<sub>e</sub>): (850 V) 3 Poles in Series, 40 C 1050 A (600 V) 3 Poles in Series, 40 C 1050 A (110 V) 1-Pole, 40 C 1050 A (110 V) 2 Poles in Series, 40 C 1050 A (220 V) 3 Poles in Series, 40 C 1050 A
  • Rated Operational Current DC-3 (I<sub>e</sub>): (850 V) 3 Poles in Series, 40 C 1050 A (600 V) 3 Poles in Series, 40 C 1050 A (110 V) 1-Pole, 40 C 1050 A (110 V) 2 Poles in Series, 40 C 1050 A (220 V) 3 Poles in Series, 40 C 1050 A
  • Rated Operational Current DC-5 (I<sub>e</sub>): (850 V) 3 Poles in Series, 40 C 1050 A (600 V) 3 Poles in Series, 40 C 1050 A (110 V) 1-Pole, 40 C 1050 A (110 V) 2 Poles in Series, 40 C 1050 A (220 V) 3 Poles in Series, 40 C 1050 A
  • Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 5 g Shock Direction: C2 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: B1 5 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Instructions and Manuals: 1SFC380023-en
  • BV Certificate: 11727/C0 BV
  • CB Certificate: SE-69481
  • CCC Certificate: CQC_2007010304256684
  • CSA Certificate: 306712-1
  • Data Sheet, Technical Information: 1SBC100122C0202
  • Declaration of Conformity - CE: 1SFA1-65
  • DNV Certificate: DNV_E-10966
  • LOVAG Certificate: SE-0151293
  • LR Certificate: LR_13_20009
  • RINA Certificate: ELE060313XG/002
  • RoHS Information: 1SFC101055D0202
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AF750-30-22-68 . Santa Clara Systems carries 36,673 items from ABB.
  • Dc
  • A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
  • Isolation
  • By-Pass And Distribution Application Up To Max 1000 V. Operated With Wide Control Voltage Range 24-60 V

Alternates

  • 1SFL637001R6822
  • AF750 30 22 68
  • AF750302268

Common Typos

  • AF750-30-22-6B
  • AF750-30-22-G8
  • AF750-30-22-GB
  • AF750-30-2Z-68
  • AF750-30-2Z-6B
  • AF750-30-2Z-G8
  • AF750-30-2Z-GB
  • AF750-30-Z2-68
  • AF750-30-Z2-6B
  • AF750-30-Z2-G8
  • AF750-30-Z2-GB
  • AF750-30-ZZ-68
  • AF750-30-ZZ-6B
  • AF750-30-ZZ-G8
  • AF750-30-ZZ-GB
  • AF750-3O-22-68
  • AF750-3O-22-6B
  • AF750-3O-22-G8
  • AF750-3O-22-GB
  • AF750-3O-2Z-68
  • AF750-3O-2Z-6B
  • AF750-3O-2Z-G8
  • AF750-3O-2Z-GB
  • AF750-3O-Z2-68
  • AF750-3O-Z2-6B
  • AF750-3O-Z2-G8

Appended Numbers

  • AF750-30-22-68-A
  • AF750-30-22-68-B
  • AF750-30-22-68-C
  • AF750-30-22-68-D
  • AF750-30-22-68-E
  • AF750-30-22-68-F
  • AF750-30-22-68-G
  • AF750-30-22-68-H
  • AF750-30-22-68-I
  • AF750-30-22-68-J
  • AF750-30-22-68-K
  • AF750-30-22-68-L
  • AF750-30-22-68-M
  • AF750-30-22-68-N
  • AF750-30-22-68-O
  • AF750-30-22-68-P
  • AF750-30-22-68-Q
  • AF750-30-22-68-R
  • AF750-30-22-68-S
  • AF750-30-22-68-T
  • AF750-30-22-68-U
  • AF750-30-22-68-V
  • AF750-30-22-68-W
  • AF750-30-22-68-X
  • AF750-30-22-68-Y
  • AF750-30-22-68-Z

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo