• ABB AF116-40-00-12 AF116-40-00-12 Contactor Product Image
  • Abb AF116-40-00-12 Barcode

AF116-40-00-12

Let Us Find It

Current response time:

12 Minutes 8 Seconds
  • Description: AF116-40-00-12 Contactor
  • Product ID: 1SFL427101R1200
  • Extended Product Type: 1SFL427101R1200
  • Product Net Weight: 2.05 kg
  • Product Net Width: 120 mm
  • Product Net Height: 150 mm
  • Product Net Depth: 128,1 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 C Close to Contactor for Storage -40+70 C
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 8 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Terminal Type: Double Clamp
  • Rated Frequency (f): Main Circuit 60 Hz
  • Number of Auxiliary Contacts NO: 0
  • Number of Auxiliary Contacts NC: 0
  • Mechanical Durability: 5 million
  • Connecting Capacity Main Circuit: Flexible 2x1070 mm Rigid Cu-Cable 2x1095 mm
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): 60 Hz 48130 V 50 Hz 48130 V DC Operation 48130 V
  • Maximum Mechanical Switching Frequency: 300 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Solid 2x14 mm Flexible with Insulated Ferrule 2x0.752.5 mm Stranded 2x14 mm Flexible 1x0.752.5 mm Flexible with Ferrule 2x0.752.5 mm
  • Operate Time: Between Coil Energization and NO Contact Closing 2055 ms Between Coil De-energization and NO Contact Opening 4070 ms
  • Number of Main Contacts NO: 4
  • Number of Main Contacts NC: 0
  • Short-Circuit Protective Devices: gG Type Fuses 200 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 2000 A
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 170 V&#183;A Holding at Max. Rated Control Circuit Voltage DC 2.5 W Holding at Max. Rated Control Circuit Voltage 50 Hz 4 V&#183;A Pull-in at Max. Rated Control Circuit Voltage DC 130 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 170 V&#183;A Holding at Max. Rated Control Circuit Voltage 60 Hz 4 V&#183;A
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at 70 C) C
  • EAN: 7320500503997
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • Package Level 1 Gross Weight: 2.25 kg
  • Package Level 1 Units: 1 piece
  • Rated Operational Voltage: Main Circuit 690 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 160 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 160 A (690 V) 70 C 130 A (690 V) 60 C 145 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (415 V) 55 C 116 A (220 / 230 / 240 V) 55 C 116 A (440 V) 55 C 116 A (380 / 400 V) 55 C 116 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 30 kW (380 / 400 V) 55 kW (440 V) 75 kW (415 V) 55 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 928 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 536 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
  • Maximum Electrical Switching Frequency: AC-1 300 cycles per hour
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AF116-40-00-12 . Santa Clara Systems carries 36,673 items from ABB.
  • 50/60 Hz And Dc
  • A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
  • Isolation
  • By-Pass And Distribution Application Up To Max 690 V. Operated With Wide Control Voltage Range 48-130 V

Alternates

  • 1SFL427101R1200
  • AF116 40 00 12
  • AF116400012

Common Typos

  • AF116-40-00-1Z
  • AF116-40-00-I2
  • AF116-40-00-IZ
  • AF116-40-00-L2
  • AF116-40-00-LZ
  • AF116-40-0O-12
  • AF116-40-0O-1Z
  • AF116-40-0O-I2
  • AF116-40-0O-IZ
  • AF116-40-0O-L2
  • AF116-40-0O-LZ
  • AF116-40-O0-12
  • AF116-40-O0-1Z
  • AF116-40-O0-I2
  • AF116-40-O0-IZ
  • AF116-40-O0-L2
  • AF116-40-O0-LZ
  • AF116-40-OO-12
  • AF116-40-OO-1Z
  • AF116-40-OO-I2
  • AF116-40-OO-IZ
  • AF116-40-OO-L2
  • AF116-40-OO-LZ
  • AF116-4O-00-12
  • AF116-4O-00-1Z
  • AF116-4O-00-I2

Appended Numbers

  • AF116-40-00-12-A
  • AF116-40-00-12-B
  • AF116-40-00-12-C
  • AF116-40-00-12-D
  • AF116-40-00-12-E
  • AF116-40-00-12-F
  • AF116-40-00-12-G
  • AF116-40-00-12-H
  • AF116-40-00-12-I
  • AF116-40-00-12-J
  • AF116-40-00-12-K
  • AF116-40-00-12-L
  • AF116-40-00-12-M
  • AF116-40-00-12-N
  • AF116-40-00-12-O
  • AF116-40-00-12-P
  • AF116-40-00-12-Q
  • AF116-40-00-12-R
  • AF116-40-00-12-S
  • AF116-40-00-12-T
  • AF116-40-00-12-U
  • AF116-40-00-12-V
  • AF116-40-00-12-W
  • AF116-40-00-12-X
  • AF116-40-00-12-Y
  • AF116-40-00-12-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo