- Description: NL40E 60V DC Contactor Relay
- Product ID: 1SBH143001R8440
- Extended Product Type: 1SBH143001R8440
- Product Net Weight: 0.520 kg
- Product Net Width: 44 mm
- Product Net Height: 78 mm
- Product Net Depth: 97 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Ambient Air Temperature: Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 C Near Contactor for Operation in Free Air (Uc) -40 ... +70 C Close to Contactor for Storage -60 ... +80 C
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
- Terminal Type: Screw Terminals
- Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
- Number of Auxiliary Contacts NO: 4
- Number of Auxiliary Contacts NC: 0
- GOST Certificate: GOST_POCCFRME77B07174
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): DC Operation 60 V
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Mechanical Switching Frequency: 6000 cycles per hour
- Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
- Operate Time: Between Coil Energization and NO Contact Closing 50 ... 100 ms Between Coil De-energization and NO Contact Opening 10 ... 17 ms
- GL Certificate: GL_26306_05HH
- Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A
- Coil Consumption: Average Holding Value, from Warm State 3 W Average Pull-in Value, from Cold State 3 W
- Coil Operating Limits: (acc. to IEC 60947-5-1) 0.85 ... 1.1 x Uc (at 55 C) C
- EAN: 3471522294845
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Package Level 1 Width: 86 mm
- Package Level 1 Length: 141 mm
- Package Level 1 Height: 51 mm
- Package Level 1 Gross Weight: 0.52 kg
- Package Level 1 EAN: 3471522294845
- Package Level 2 Units: 28 piece
- Package Level 3 Units: 336 piece
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-5-1, q = 40 C 16 A
- Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I<sub>cw</sub>): for 0.1 s 140 A for 1 s 100 A
- Maximum Electrical Switching Frequency: 1200 cycles per hour
- Rated Operational Current DC-13 (I<sub>e</sub>): (125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: A 20 g Open, Shock Direction: A 10 g Closed, Shock Direction: B1 15 g Open, Shock Direction: B1 5 g Shock Direction: B2 10 g Closed, Shock Direction: C1 20 g Open, Shock Direction: C1 8 g Closed, Shock Direction: C2 14 g Open, Shock Direction: C2 8 g
- RoHS Status: Following EU Directive 2011/65/EC
- Instructions and Manuals: 1SBC101003M5501
- CB Certificate: CB_SE_66833A1
- CCC Certificate: CCC_2012010304558126
- CSA Certificate: CSA_1041746
- cUL Certificate: UL_110105E48139A
- Data Sheet, Technical Information: 1SBC100122C0202_Ch03
- Declaration of Conformity - CE: 1SBD250808U1000
- LOVAG Certificate: LOVAG_FR04027
- RoHS Information: 1SBD350053R1001
- UL Certificate: UL_110105E48139A
- ETIM 4: EC000196 - Contactor relay
- ETIM 5: EC000196 - Contactor relay
- ETIM 6: EC000196 - Contactor relay
- UNSPSC: 39121500
- Object Classification Code: K
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on NL40E-84 . Santa Clara Systems carries 36,687 items from ABB.
- Nl... Contactor Relays Are Used For Switching Auxiliary Circuits And Control Circuits - Poles: 4-Pole Contactor Relays (Mechanically Linked Contact Elements Available) - Control Circuit: Dc Operated With Solid Core Magnet Circuit. The Polarity On The Coil Terminals (A1+ And A2-) Must Be Respected - Accessories: A Wide Range Of Accessories Is Available Nl... Contactors Are Fitted With Low Consumption Dc Coils And Are Suitable For A Direct Control By Plc Outputs.
Alternates
- 1SBH143001R8440
- NL40E 84
- NL40E84
Common Typos
- N140E-84
- N140E-B4
- N14OE-84
- N14OE-B4
- NI40E-84
- NI40E-B4
- NI4OE-84
- NI4OE-B4
- NL40E-B4
- NL4OE-84
- NL4OE-B4
Appended Numbers
- NL40E-84-A
- NL40E-84-B
- NL40E-84-C
- NL40E-84-D
- NL40E-84-E
- NL40E-84-F
- NL40E-84-G
- NL40E-84-H
- NL40E-84-I
- NL40E-84-J
- NL40E-84-K
- NL40E-84-L
- NL40E-84-M
- NL40E-84-N
- NL40E-84-O
- NL40E-84-P
- NL40E-84-Q
- NL40E-84-R
- NL40E-84-S
- NL40E-84-T
- NL40E-84-U
- NL40E-84-V
- NL40E-84-W
- NL40E-84-X
- NL40E-84-Y
- NL40E-84-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier