- Description: Contactor | 1SBL181001R3410
- Product ID: 1SBL181001R3410
- Extended Product Type: 1SBL181001R3410
- Product Net Weight: 0.340 kg
- Product Net Width: 44 mm
- Product Net Height: 74 mm
- Product Net Depth: 74 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 C Close to Contactor for Storage -60 ... +80 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 C
- Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
- Terminal Type: Screw Terminals
- Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 0
- Mechanical Durability: 10 million
- Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
- GOST Certificate: GOST_POCCFRME77B07175
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 175 V 60 Hz 208 V
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
- Operate Time: Between Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
- Number of Main Contacts NO: 3
- GL Certificate: DNV-GL_TAE00000TX
- Number of Main Contacts NC: 0
- Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 32 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
- Coil Consumption: Average Holding Value 50 Hz 8 V·A Average Holding Value 50 Hz 2 W Average Holding Value 60 Hz 8 V·A Average Holding Value 60 Hz 2 W Average Pull-in Value 50 Hz 70 V·A Average Pull-in Value 60 Hz 80 V·A
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) C
- Connecting terminals (delivered in open position) Main poles: M 3.5 (+,-) pozidriv 2 screws with cable clamp
- EAN: 3471522050342
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Package Level 1 Width: 78 mm
- Package Level 1 Length: 76 mm
- Package Level 1 Height: 47 mm
- Package Level 1 Gross Weight: 0.34 kg
- You searched for alternate part: 1SBL181001R3410
- Package Level 1 EAN: 3471522050342
- Package Level 2 Units: 63 piece
- Package Level 3 Units: 1220 piece
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 30 A acc. to IEC 60947-5-1, q = 40 C 16 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 30 A (690 V) 55 C 27 A (690 V) 70 C 23 A
- Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 55 C 17 A (380 / 400 V) 55 C 17 A (415 V) 55 C 17 A (440 V) 55 C 16 A (500 V) 55 C 14 A (690 V) 55 C 10 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 4 kW (380 / 400 V) 7.5 kW (415 V) 9 kW (440 V) 9 kW (500 V) 9 kW (690 V) 9 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 140 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 30 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
- Rated Operational Current DC-13 (I<sub>e</sub>): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
- Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: FPTC407721P0001
- BV Certificate: BV_2634H07559D0
- CB Certificate: CB_FR_602227A
- CCC Certificate: CCC_2013010304615753 CCC_2004010309130463
- CSA Certificate: CSA_1041746
- cUL Certificate: UL_20160205-E312527-10-2
- Data Sheet, Technical Information: 1SBC100122C0202_Ch02
- Declaration of Conformity - CE: 1SBD250801U1000
- DNV Certificate: DNV-GL_TAE00000TX
- EAC Certificate: EAC_RU C-FR ME77 B01010
- LOVAG Certificate: LOVAG_FR97039
- LR Certificate: LRS_9830011E4
- RINA Certificate: RINA_ELE128713XG001
- RMRS Certificate: RMRS_0507015250
- RoHS Information: 1SBD350050R1000
- UL Certificate: UL_071301E39231
- UL Listing Card: UL_E312527
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on A16-30-10-34 . Santa Clara Systems carries 36,879 items from ABB.
- 1 Built-In Auxiliary Contact
- Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.
- A16 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac Or 220 V Dc. The Contactors Can Also Be Used For Many Other Applications Such As Isolation
- Capacitor Switching
- Lighting. The A... Series 1-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles
Alternates
- 1SBL181001R3410
- A16 30 10 34
- A16301034
Common Typos
- A16-30-1O-34
- A16-30-I0-34
- A16-30-IO-34
- A16-30-L0-34
- A16-30-LO-34
- A16-3O-10-34
- A16-3O-1O-34
- A16-3O-I0-34
- A16-3O-IO-34
- A16-3O-L0-34
- A16-3O-LO-34
- A1G-30-10-34
- A1G-30-1O-34
- A1G-30-I0-34
- A1G-30-IO-34
- A1G-30-L0-34
- A1G-30-LO-34
- A1G-3O-10-34
- A1G-3O-1O-34
- A1G-3O-I0-34
- A1G-3O-IO-34
- A1G-3O-L0-34
- A1G-3O-LO-34
- AI6-30-10-34
- AI6-30-1O-34
- AI6-30-I0-34
Appended Numbers
- A16-30-10-34-A
- A16-30-10-34-B
- A16-30-10-34-C
- A16-30-10-34-D
- A16-30-10-34-E
- A16-30-10-34-F
- A16-30-10-34-G
- A16-30-10-34-H
- A16-30-10-34-I
- A16-30-10-34-J
- A16-30-10-34-K
- A16-30-10-34-L
- A16-30-10-34-M
- A16-30-10-34-N
- A16-30-10-34-O
- A16-30-10-34-P
- A16-30-10-34-Q
- A16-30-10-34-R
- A16-30-10-34-S
- A16-30-10-34-T
- A16-30-10-34-U
- A16-30-10-34-V
- A16-30-10-34-W
- A16-30-10-34-X
- A16-30-10-34-Y
- A16-30-10-34-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier