- Description: MO325-25 Manual Motor Starter Magnetic Only
- Product ID: 1SAM160000R1014
- Extended Product Type: 1SAM160000R1014
- Product Net Weight: 0.34 kg
- Product Net Width: 54 mm
- Product Net Height: 87.5 mm
- Product Net Depth: 75.5 mm
- Degree of Protection: IP20
- Ambient Air Temperature: Around the Enclosure 0 ... +40 C Operation -25 ... +50 C Storage -50 ... +80 C
- Standards: IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 508 CSA 22.2 No. 14
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 6 kV
- Rated Insulation Voltage (U<sub>i</sub>): 690 V
- Number of Poles: 3
- Rated Frequency (f): Main Circuit 50 Hz Main Circuit 60 Hz
- Power Loss: at Rated Operating Conditions per Pole 1.7 W
- Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- eClass: 7.0 27370401
- Tightening Torque: Main Circuit 1.4 N·m
- Actuator Type: Rotary Handle
- Mounting Position: Position 1 to 6
- Mechanical Durability: 100000 cycle
- Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 0.75 ... 4 mm Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm Flexible 1/2x 1 ... 6 mm Rigid 1/2x 1 ... 6 mm
- GOST Certificate: 1SAA918000-2703
- Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
- Contact Position Indication: ON / OFF
- Maximum Operating Altitude Permissible: 2000 m
- Tightening Torque UL/CSA: Main Circuit 14 in·lb
- Wire Stripping Length: Main Circuit 10 mm
- GL Certificate: 1SAA918000-0403
- Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 14-8 AWG Stranded 1/2x 14-8 AWG
- Ampere Rating UL/CSA: 25 A
- Horsepower Rating UL/CSA: (220 ... 240 V AC) Three Phase 7.5 Hp (440 ... 480 V AC) Three Phase 15 Hp (550 ... 600 V AC) Three Phase 20 Hp
- Electrical Durability: 50000 cycle
- EAN: 4013614302107
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362010
- Package Level 1 Width: 92 mm
- Package Level 1 Length: 58 mm
- Package Level 1 Height: 78 mm
- Package Level 1 Gross Weight: 0.37 kg
- Package Level 2 Units: 24 piece
- Package Level 2 Width: 280 mm
- Package Level 2 Length: 395 mm
- Package Level 2 Height: 210 mm
- Package Level 2 Gross Weight: 0.61 kg
- Package Level 2 EAN: 4013614495069
- Package Level 1 Units: 1 piece
- Rated Ultimate Short-Circuit Breaking Capacity (I<sub>cu</sub>): (230 V AC) 100 kA (400 V AC) 50 kA (440 V AC) 30 kA (500 V AC) 20 kA (690 V AC) 3 kA
- Rated Instantaneous Short-Circuit Current Setting (I<sub>i</sub>): 375 A
- Setting Range: None
- Rated Operational Voltage: Main Circuit 690 V AC Main Circuit 440 V DC
- Rated Operational Current (I<sub>e</sub>): 25 A
- Rated Operational Current AC-3 (I<sub>e</sub>): 25 A
- Conventional Free-air Thermal Current (I<sub>th</sub>): Main Circuit 25 A
- Pollution Degree: 3
- Recommended Screw Driver: M3.5 Pozidriv 2
- Remarks: For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
- Rated Service Short-Circuit Breaking Capacity (I<sub>cs</sub>): (230 V AC) 100 kA (400 V AC) 50 kA (440 V AC) 30 kA (500 V AC) 20 kA (690 V AC) 3 kA
- Ambient Air Temperature Compensation: No
- Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 15g
- Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 10 ... 150 Hz
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: 1SAM107011P0003
- CB Certificate: 1SAA918000-2002
- CCC Certificate: 1SAA918000-3806
- cUL Certificate: cUL_E137861
- cULus Certificate: E137861
- Data Sheet, Technical Information: 2CDC130002C0206
- Declaration of Conformity - CE: 1SAD938506-0037
- DNV Certificate: 1SAA918000-0305
- LR Certificate: 1SAA918000-0503
- RINA Certificate: 1SAA918000-0803
- RMRS Certificate: 1SAA918000-0703
- RoHS Information: 1SAA918001-4401
- UL Certificate: UL_E137861
- ETIM 4: EC000074 - Motor protective circuit-breaker
- ETIM 5: EC000074 - Motor protective circuit-breaker
- ETIM 6: EC000074 - Motor protection circuit-breaker
- UNSPSC: 39121521
- Object Classification Code: F
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on MO325-25 . Santa Clara Systems carries 36,687 items from ABB.
- Shunt Trips
- 3-Phase Bus Bars
- Power In-Feed Blocks Are Available As Accessory.
- The Mo325-25 Manual Motor Starter Magnetic Only Is A 54 Mm Width Device With A Rated Operational Current Of Ie = 25.0 A. This Device Is Used To Manually Switch On And Off Motors And To Protect Them Reliably And Without The Need For A Fuse From Short-Circuits. The Manual Motor Starter Magnetic Only Offers A Rated Service Short-Circuit Breaking Capacity Ics = 50 Ka At 400 Vac. Further Features Are The Build-In Disconnect Function
- Trip-Free Mechanism And A Rotary Handle With A Clear Switch Position Indication. The Manual Motor Starter Magnetic Only Is Suitable For Three- And Single-Phase Applications. Auxiliary Contacts
- Signalling Contacts
- Undervoltage Releases
Alternates
- 1SAM160000R1014
- MO325 25
- MO32525
Common Typos
- M0325-25
- M0325-2S
- M0325-Z5
- M0325-ZS
- M032S-25
- M032S-2S
- M032S-Z5
- M032S-ZS
- M03Z5-25
- M03Z5-2S
- M03Z5-Z5
- MO325-2S
- MO325-Z5
- MO325-ZS
- MO32S-25
- MO32S-2S
- MO32S-Z5
- MO32S-ZS
- MO3Z5-25
- MO3Z5-2S
- MO3Z5-Z5
- MO3Z5-ZS
- MO3ZS-25
- MO3ZS-2S
- MO3ZS-Z5
- MO3ZS-ZS
Appended Numbers
- MO325-25-A
- MO325-25-B
- MO325-25-C
- MO325-25-D
- MO325-25-E
- MO325-25-F
- MO325-25-G
- MO325-25-H
- MO325-25-I
- MO325-25-J
- MO325-25-K
- MO325-25-L
- MO325-25-M
- MO325-25-N
- MO325-25-O
- MO325-25-P
- MO325-25-Q
- MO325-25-R
- MO325-25-S
- MO325-25-T
- MO325-25-U
- MO325-25-V
- MO325-25-W
- MO325-25-X
- MO325-25-Y
- MO325-25-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier