- Description: AF26ZB-30-00-23 100-250V50/60HZ-DC Contactor
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 1200 cycles per hour
- Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
- Rated Impulse Withstand Voltage (Uimp): 6 kV
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Rated Control Circuit Voltage (Uc): 50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
- Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms
- Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 1.5...10 mm² Flexible with Insulated Ferrule 2x 1.5...4 mm² Flexible with Ferrule 1/2x 1.5...10 mm² Rigid 1/2x 2.5...10 mm²
- Wire Stripping Length: Main Circuit 14 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Terminal Type: Screw Terminals
- Number of Main Contacts NO: 3
- Climatic Withstand: Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible: 3000 m
- RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q4
- Ambient Air Temperature: Close to Contactor for Storage -60...+80 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C
- General Use Rating UL/CSA: (600 V AC) 45 A
- Horsepower Rating UL/CSA: (120 V AC) Single Phase 2 Hp (240 V AC) Single Phase 3 Hp (200 ... 208 V AC) Three Phase 7-1/2 Hp (220 ... 240 V AC) Three Phase 7-1/2 Hp (440 ... 480 V AC) Three Phase 15 Hp (550 ... 600 V AC) Three Phase 20 Hp
- Instructions and Manuals: 1SBC101037M6801
- CB Certificate: CB_SE_70856M1
- CCC Certificate: CCC_2010010304445623
- Data Sheet, Technical Information: 1SBC100174C0201
- Declaration of Conformity - CE: 1SBD250002U1000
- EAC Certificate: EAC_RU C-FR ME77 B01010
- GOST Certificate: GOST_POCCFR.ME77.B07175.pdf
- RoHS Information: 1SBD251017E1000
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
- Extended Product Type: AF26ZB-30-00-23
- Product ID: 1SBL236061R2300
- EAN: 3471523124134
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- EAN: 3471523124134
- Product Net Depth: 86 mm
- Product Net Height: 86 mm
- Product Net Weight: 0.370 kg
- Product Net Width: 45 mm
- Package Level 1 Width: 87 mm
- Package Level 1 Length: 87 mm
- Package Level 1 Height: 47 mm
- Package Level 1 Gross Weight: 0.37 kg
- Package Level 1 EAN: 3471523124134
- Package Level 2 Units: 45 piece
- Package Level 2 Width: 250 mm
- Package Level 2 Length: 300 mm
- Package Level 2 Height: 315 mm
- Package Level 2 Gross Weight: 17.900 kg
- Package Level 3 Units: 1080 piece
- Package Level 1 Units: 1 piece
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 0
- Rated Operational Voltage: Main Circuit 690 V
- Rated Frequency (f): Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 A
- Rated Operational Current AC-1 (Ie): (690 V) 40 °C 45 A (690 V) 60 °C 40 A (690 V) 70 °C 32 A
- Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 26 A (380 / 400 V) 60 °C 26 A (415 V) 60 °C 26 A (440 V) 60 °C 26 A (500 V) 60 °C 23 A (690 V) 60 °C 17 A
- Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 6.5 kW (380 / 400 V) 11 kW (415 V) 11 kW (440 V) 15 kW (500 V) 15 kW (690 V) 15 kW
- Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Santa Clara Systems spécialise dans les pièces difficiles à trouver. Choisissez parmi notre inventaire de surstock et économiser de l’argent sur 1SBL236061R2300 . Santa Clara Systems se vend 36,195 articles de ABB.
- Class B. Reach The Highest Levels In Fire And Smoke Behaviour With Compliance To European Standard En 45545-2 (Hl2
- Hl3 Hazard Levels) In Group Mounting. Reduce Train Energy With Lighter Devices And Requiring 68% Less Coil Energy Consumption In Operation. Electronic Coil Interface Handling Large Dc Voltage Fluctuation Voltage
- Including Several Uc Dc Control Voltages Used For Battery Supply And Accepting SinusoïDal Ac 50/60 Hz Control Supplies Included Inside Ucmin.... Ucmax Voltage Range. Max Permitted Ac 50/60 Hz Control Voltage Must Not Be Exceeded (See Technical Data). Wide Range Of Auxiliary Contact Blocks For Front And Side Mounting.
Suppléants
- AF26ZB-30-00-23
- AF26ZB 30 00 23
- AF26ZB300023
Fautes de Frappe Commun
- 1SBL236061R230O
- 1SBL236061R23O0
- 1SBL236061R23OO
- 1SBL236061RZ300
- 1SBL236061RZ30O
- 1SBL236061RZ3O0
- 1SBL236061RZ3OO
- 1SBL23606IR2300
- 1SBL23606IR230O
- 1SBL23606IR23O0
- 1SBL23606IR23OO
- 1SBL23606IRZ300
- 1SBL23606IRZ30O
- 1SBL23606IRZ3O0
- 1SBL23606IRZ3OO
- 1SBL23606LR2300
- 1SBL23606LR230O
- 1SBL23606LR23O0
- 1SBL23606LR23OO
- 1SBL23606LRZ300
- 1SBL23606LRZ30O
- 1SBL23606LRZ3O0
- 1SBL23606LRZ3OO
- 1SBL2360G1R2300
- 1SBL2360G1R230O
Numéros Annexées
- 1SBL236061R2300-A
- 1SBL236061R2300-B
- 1SBL236061R2300-C
- 1SBL236061R2300-D
- 1SBL236061R2300-E
- 1SBL236061R2300-F
- 1SBL236061R2300-G
- 1SBL236061R2300-H
- 1SBL236061R2300-I
- 1SBL236061R2300-J
- 1SBL236061R2300-K
- 1SBL236061R2300-L
- 1SBL236061R2300-M
- 1SBL236061R2300-N
- 1SBL236061R2300-O
- 1SBL236061R2300-P
- 1SBL236061R2300-Q
- 1SBL236061R2300-R
- 1SBL236061R2300-S
- 1SBL236061R2300-T
- 1SBL236061R2300-U
- 1SBL236061R2300-V
- 1SBL236061R2300-W
- 1SBL236061R2300-X
- 1SBL236061R2300-Y
- 1SBL236061R2300-Z
Plus de Produits de ce Genre
-
1SBL236061R2100
ABB
-
1SBL236061R2200
ABB
-
1SBL236001R2000
ABB
-
1SBL236001R2011
ABB
Customers Are Also Buying
-
X-307923
Allen Bradley
-
1756-BATA (BATTERY)
Allen Bradley
-
140M-C2E-C10
Allen Bradley
-
855T-B10TL4
Allen Bradley
Livraison qui Répond à Vos Besoins

- ✓ Livraison Rapide pour le Côte Ouest (17 heures, heure du Pacifique)
- ✓ Spécialistes de l’Expédition directe au détaillant et d’Envoi Aveugle
- ✓ Habilement Emballé Statique-limitée
- ✓ Service le Jour Même
- ✓ Courier Intra-Muros Nationale et Internationale