- Description: Contactor | 1SBL136001R2101
- Product ID: 1SBL136001R2101
- Extended Product Type: 1SBL136001R2101
- Product Net Weight: 0.310 kg
- Product Net Width: 45 mm
- Product Net Height: 86 mm
- Product Net Depth: 77 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Ambient Air Temperature: Close to Contactor for Storage -60...+80 C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 C Close to Contactor without Thermal O/L Relay -40 ... +70 C
- Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N14
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 6 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
- Terminal Type: Screw Terminals
- Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 1
- Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 0.75...4 mm Flexible with Insulated Ferrule 2x 0.75...2.5 mm Flexible with Ferrule 1/2x 0.75...6 mm Rigid 1/2x 1...6 mm
- GOST Certificate: GOST_POCCFR.ME77.B07175.pdf
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
- Climatic Withstand: Category B according to IEC 60947-1 Annex Q
- Tightening Torque UL/CSA: Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb Main Circuit 13 in·lb
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1...2.5 mm
- Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms
- Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 10 mm
- Number of Main Contacts NO: 3
- GL Certificate: DNV-GL_E13871
- Number of Main Contacts NC: 0
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
- Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1 ... 2.5 mm
- Horsepower Rating UL/CSA: (120 V AC) Single Phase 3/4 Hp (240 V AC) Single Phase 1-1/2 Hp (200 ... 208 V AC) Three Phase 2 Hp (220 ... 240 V AC) Three Phase 2 Hp (440 ... 480 V AC) Three Phase 5 Hp (550 ... 600 V AC) Three Phase 7-1/2 Hp
- General Use Rating UL/CSA: (600 V AC) 25 A
- EAN: 3471523113312
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Package Level 1 Width: 87 mm
- Package Level 1 Length: 79 mm
- Package Level 1 Height: 47 mm
- Package Level 1 Gross Weight: 0.31 kg
- Package Level 1 EAN: 3471523113312
- Package Level 2 Units: 54 piece
- Package Level 2 Width: 250 mm
- Package Level 2 Length: 300 mm
- Package Level 2 Height: 315 mm
- Package Level 3 Units: 1296 piece
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 35 A acc. to IEC 60947-5-1, q = 40 C 16 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 25 A (690 V) 60 C 25 A (690 V) 70 C 22 A
- Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 60 C 9 A (380 / 400 V) 60 C 9 A (415 V) 60 C 9 A (440 V) 60 C 9 A (500 V) 60 C 9.5 A (690 V) 60 C 7 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 2.2 kW (380 / 400 V) 4 kW (400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW
- Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 150 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 35 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour
- Rated Operational Current DC-13 (I<sub>e</sub>): (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (48 V) 2.8 A / 134 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W (72 V) 1 A / 72 W
- Resistance to Vibrations acc. to IEC 60068-2-6: 5...300 Hz 4 g closed position / 2 g open position
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g
- RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1
- Instructions and Manuals: 1SBC101027M6801
- ABS Certificate: ABS_15-GE1349500-PDA_90682247
- CB Certificate: CB_SE_70855M1
- CCC Certificate: CCC_2010010304445624
- cUL Certificate: UL_20091124-E312527-7-1
- Data Sheet, Technical Information: 1SBC101402D0201
- Declaration of Conformity - CE: 1SBD250000U1000
- DNV Certificate: DNV-GL_E13871
- EAC Certificate: EAC_RU C-FR ME77 B01010
- LR Certificate: LRS_1300087E1
- RINA Certificate: RINA_ELE084013XG
- RMRS Certificate: RMRS_1400682124
- RoHS Information: 1SBD251013E1000
- E-nummer: 3210006
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AF09Z-30-01-21 . Santa Clara Systems carries 36,836 items from ABB.
- Front And Side-Mounted Add-On Auxiliary Contact Blocks. (Mechanically-Linked Auxiliary Contacts Compliant With Annex L Of Iec 60947-5-1. N.c. Mirror Contacts Compliant With Annex F Of Iec 60947-4-1) - Control Circuit: Ac Or Dc Operated - Accessories: A Wide Range Of Accessories Is Available.
- Af09z Contactors Are Used For Controlling Power Circuits Up To 690 V Ac And 220 V Dc. They Are Mainly Used For Controlling 3-Phase Motors
- Non-Inductive Or Slightly Inductive Loads. Af..z Contactors Include An Electronic Coil Interface Accepting A Wide Control Voltage Uc Min. ... Uc Max. Only Four Coils Cover Control Voltages Between 24...250 V 50/60 Hz Or 12...250 V Dc. Af..z Contactors Can Manage Large Control Voltage Variations. One Coil Can Be Used For Different Control Voltages Used Worldwide Without Any Coil Change. Af..z Contactors Allow Direct Control By Plc-Output ? 24 V Dc 500 Ma And Obtain A Reduced Holding Coil Consumption. Af..z Contactors Withstand Short Voltage Dips And Voltage Sags (Semi F47-0706 Compliance) Between 24...250 V 50/60 Hz Af..z Contactors Have Built-In Surge Protection And Do Not Require Additional Surge Suppressors The Af... Series 1-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles
- 1 Built-In Auxiliary Contact
Alternates
- 1SBL136001R2101
- AF09Z 30 01 21
- AF09Z300121
Common Typos
- AF09Z-30-01-2I
- AF09Z-30-01-2L
- AF09Z-30-01-Z1
- AF09Z-30-01-ZI
- AF09Z-30-01-ZL
- AF09Z-30-0I-21
- AF09Z-30-0I-2I
- AF09Z-30-0I-2L
- AF09Z-30-0I-Z1
- AF09Z-30-0I-ZI
- AF09Z-30-0I-ZL
- AF09Z-30-0L-21
- AF09Z-30-0L-2I
- AF09Z-30-0L-2L
- AF09Z-30-0L-Z1
- AF09Z-30-0L-ZI
- AF09Z-30-0L-ZL
- AF09Z-30-O1-21
- AF09Z-30-O1-2I
- AF09Z-30-O1-2L
- AF09Z-30-O1-Z1
- AF09Z-30-O1-ZI
- AF09Z-30-O1-ZL
- AF09Z-30-OI-21
- AF09Z-30-OI-2I
- AF09Z-30-OI-2L
Appended Numbers
- AF09Z-30-01-21-A
- AF09Z-30-01-21-B
- AF09Z-30-01-21-C
- AF09Z-30-01-21-D
- AF09Z-30-01-21-E
- AF09Z-30-01-21-F
- AF09Z-30-01-21-G
- AF09Z-30-01-21-H
- AF09Z-30-01-21-I
- AF09Z-30-01-21-J
- AF09Z-30-01-21-K
- AF09Z-30-01-21-L
- AF09Z-30-01-21-M
- AF09Z-30-01-21-N
- AF09Z-30-01-21-O
- AF09Z-30-01-21-P
- AF09Z-30-01-21-Q
- AF09Z-30-01-21-R
- AF09Z-30-01-21-S
- AF09Z-30-01-21-T
- AF09Z-30-01-21-U
- AF09Z-30-01-21-V
- AF09Z-30-01-21-W
- AF09Z-30-01-21-X
- AF09Z-30-01-21-Y
- AF09Z-30-01-21-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier