  • Description: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 220 V AC coil
  • Product weight: 0.73 lb(US) (0.33 kg)
  • Range of product: TeSys D
  • IP degree of protection: IP20 front face conforming to IEC 60529
  • Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Device short name: LC1D
  • Width: 1.77 in (45 mm)
  • Height: 3.03 in (77 mm)
  • Depth: 3.39 in (86 mm)
  • Protective treatment: TH conforming to IEC 60068-2-30
  • [Ui] rated insulation voltage: 600 V power circuit certifications CSA, 600 V power circuit certifications UL, 690 V power circuit conforming to IEC 60947-4-1, 690 V signaling circuit conforming to IEC 60947-1, 600 V signaling circuit certifications CSA, 600 V signaling circuit certifications UL
  • [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
  • Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
  • Mechanical durability: 15 Mcycles
  • Tightening torque: Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat 6 mm, Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2, Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat 6 mm, Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2
  • Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - with cable end, Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in (1...6 mm) - cable stiffness: flexible - with cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: flexible - with cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: solid - without cable end, Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: solid - without cable end, Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in (1.5...6 mm) - cable stiffness: flexible - without cable end, Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in (1.5...6 mm) - cable stiffness: flexible - without cable end, Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: flexible - with cable end, Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in (1.5...6 mm) - cable stiffness: solid - without cable end, Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in (1.5...6 mm) - cable stiffness: solid - without cable end
  • Range: TeSys
  • Mounting support: Rail, Plate
  • [Ith] conventional free air thermal current: 32 A at <= 140 F (60 C) power circuit, 10 A at <= 140 F (60 C) signaling circuit
  • System Voltage: <= 300 V DC power circuit, <= 690 V AC 25...400 Hz power circuit
  • Operating rate: 3600 cyc/h at <= 140 F (60 C)
  • Product name: TeSys D
  • [Uc] control circuit voltage: 220 V AC 50/60 Hz
  • Electrical durability: 1.65 Mcycles 18 A AC-3 at Ue <= 440 V, 1 Mcycles 32 A AC-1 at Ue <= 440 V
  • Insulation resistance: > 10 MOhm signaling circuit
  • motor power kW: 10 kW at 500 V AC 50/60 Hz AC-3, 10 kW at 660...690 V AC 50/60 Hz AC-3, 4 kW at 220...230 V AC 50/60 Hz AC-3, 7.5 kW at 380...400 V AC 50/60 Hz AC-3, 9 kW at 415...440 V AC 50/60 Hz AC-3, 4 kW at 400 V AC 50/60 Hz AC-4
  • [Ie] rated operational current: 18 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit, 32 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit
  • Utilization category: AC-4, AC-1, AC-3
  • Control circuit voltage limits: 0.3...0.6 Uc drop-out at 140 F (60 C), AC 50/60 Hz, 0.8...1.1 Uc operational at 140 F (60 C), AC 50 Hz, 0.85...1.1 Uc operational at 140 F (60 C), AC 60 Hz
  • Poles description: 3P
  • Overvoltage category: III
  • Operating time: 4...19 ms opening, 12...22 ms closing
  • Associated fuse rating: 35 A gG at <= 690 V coordination type 2 power circuit, 50 A gG at <= 690 V coordination type 1 power circuit, 10 A gG signaling circuit conforming to IEC 60947-5-1
  • Control circuit type: AC 50/60 Hz
  • Coil technology: Without built-in suppressor module
  • inrush power in VA: 70 VA at 68 F (20 C) (cos ? 0.75) 60 Hz, 70 VA at 68 F (20 C) (cos ? 0.75) 50 Hz
  • Pollution degree: 3
  • Product or component type: Contactor
  • hold-in power consumption in VA: 7.5 VA at 68 F (20 C) (cos ? 0.3) 60 Hz, 7 VA at 68 F (20 C) (cos ? 0.3) 50 Hz
  • Ambient air temperature for operation: 23...140 F (-5...60 C)
  • Heat dissipation: 2...3 W at 50/60 Hz
  • Ambient air temperature for storage: -76...176 F (-60...80 C)
  • Contactor application: Resistive load, Motor control
  • Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1, Type mirror contact (1 NC) conforming to IEC 60947-4-1
  • Permissible ambient air temperature around the device: -40...158 F (-40...70 C) at Uc
  • Signaling circuit frequency: 25...400 Hz
  • Minimum switching current: 5 mA signaling circuit
  • Fire resistance: 1562 F (850 C) conforming to IEC 60695-2-1
  • Pole contact composition: 3 NO
  • Minimum switching voltage: 17 V signaling circuit
  • Flame retardance: V1 conforming to UL 94
  • Non-overlap time: 1.5 ms on energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact
  • Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 Hz, Vibrations contactor closed 4 Gn, 5...300 Hz, Shocks contactor open 10 Gn for 11 ms, Shocks contactor closed 15 Gn for 11 ms
  • Power range: 7...11 kW 380...440 V 3 phases, 7...11 kW 480...500 V 3 phases, 4...6 kW 200...240 V 3 phases
  • Motor power hp: 1 hp at 115 V AC 50/60 Hz 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz 1 phase motors, 5 hp at 200/208 V AC 50/60 Hz 3 phases motors, 5 hp at 230/240 V AC 50/60 Hz 3 phases motors, 10 hp at 460/480 V AC 50/60 Hz 3 phases motors, 15 hp at 575/600 V AC 50/60 Hz 3 phases motors
  • Motor starter type: Direct on-line contactor
  • Contactor coil voltage: 220 V AC standard
  • Auxiliary contact composition: 1 NO + 1 NC
  • Irms rated making capacity: 300 A at 440 V power circuit conforming to IEC 60947, 140 A AC signaling circuit conforming to IEC 60947-5-1, 250 A DC signaling circuit conforming to IEC 60947-5-1
  • Rated breaking capacity: 300 A at 440 V power circuit conforming to IEC 60947
  • [Icw] rated short-time withstand current: 145 A <= 104 F (40 C) 10 s power circuit, 240 A <= 104 F (40 C) 1 s power circuit, 40 A <= 104 F (40 C) 10 min power circuit, 84 A <= 104 F (40 C) 1 min power circuit, 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 140 A 100 ms signaling circuit
  • Average impedance: 2.5 mOhm at 50 Hz - Ith 32 A power circuit
  • Power dissipation per pole: 0.8 W AC-3, 2.5 W AC-1
  • Protective cover: With
  • Product certifications: UL, CSA, CCC, DNV, BV, RINA, LROS (Lloyds register of shipping), GOST, GL
  • Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1D18M7 . Santa Clara Systems carries 10,296 items from Telemecanique.
  • Tesys D Contactor - 3p(3 No) - Ac-3 - <= 440 V 18 A - 220 V Ac Coil

Alternates

    Common Typos

    • 1C1D18M7
    • 1C1D1BM7
    • 1C1DI8M7
    • 1C1DIBM7
    • 1C1DL8M7
    • 1C1DLBM7
    • 1CID18M7
    • 1CID1BM7
    • 1CIDI8M7
    • LC1D1BM7
    • LC1DI8M7
    • LC1DIBM7
    • LC1DL8M7
    • LC1DLBM7
    • LCID18M7
    • LCID1BM7
    • LCIDI8M7
    • LCIDIBM7
    • LCIDL8M7
    • LCIDLBM7
    • LCLD18M7
    • LCLD1BM7
    • LCLDI8M7
    • LCLDIBM7
    • LCLDL8M7
    • LCLDLBM7

    Appended Numbers

    • LC1D18M7-A
    • LC1D18M7-B
    • LC1D18M7-C
    • LC1D18M7-D
    • LC1D18M7-E
    • LC1D18M7-F
    • LC1D18M7-G
    • LC1D18M7-H
    • LC1D18M7-I
    • LC1D18M7-J
    • LC1D18M7-K
    • LC1D18M7-L
    • LC1D18M7-M
    • LC1D18M7-N
    • LC1D18M7-O
    • LC1D18M7-P
    • LC1D18M7-Q
    • LC1D18M7-R
    • LC1D18M7-S
    • LC1D18M7-T
    • LC1D18M7-U
    • LC1D18M7-V
    • LC1D18M7-W
    • LC1D18M7-X
    • LC1D18M7-Y
    • LC1D18M7-Z

    More Products Like This

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo