• Telemecanique LC1 D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 110 V AC 50/60 Hz coil Product Image
  • Telemecanique LC1 D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 110 V AC 50/60 Hz coil Product Image
  • Telemecanique LC1 D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 110 V AC 50/60 Hz coil Product Image
  • Telemecanique LC1 D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 110 V AC 50/60 Hz coil Product Image
  • Telemecanique LC1 D80F7 Barcode

LC1D80F7

Get a Quote

Current response time:

14 Minutes 44 Seconds
  • Description: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 110 V AC 50/60 Hz coil
  • Product weight: 3.51 lb(US) (1.59 kg)
  • Range of product: TeSys D
  • IP degree of protection: IP20 front face conforming to IEC 60529
  • Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Device short name: LC1D
  • Width: 3.35 in (85 mm)
  • Height: 5 in (127 mm)
  • Depth: 5.12 in (130 mm)
  • Protective treatment: TH conforming to IEC 60068-2-30
  • [Ui] rated insulation voltage: 1000 V power circuit conforming to IEC 60947-4-1, 600 V power circuit certifications CSA, 600 V power circuit certifications UL, 690 V signaling circuit conforming to IEC 60947-1, 600 V signaling circuit certifications CSA, 600 V signaling circuit certifications UL
  • [Uimp] rated impulse withstand voltage: Conforming to IEC 60947
  • Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
  • Mechanical durability: 4 Mcycles
  • Tightening torque: Power circuit: 79.65 lbf.in (9 N.m) - on connector - with screwdriver flat 6 to 8 mm, Power circuit: 79.65 lbf.in (9 N.m) - on connector hexagonal 0.16 in (4 mm), Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver flat 6 mm, Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver Philips No 2
  • Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - with cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: solid - without cable end, Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: solid - without cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - with cable end, Power circuit: connector 1 cable(s) 0.01...0.08 in (4...50 mm) - cable stiffness: flexible - without cable end, Power circuit: connector 2 cable(s) 0.01...0.04 in (4...25 mm) - cable stiffness: flexible - without cable end, Power circuit: connector 1 cable(s) 0.01...0.08 in (4...50 mm) - cable stiffness: flexible - with cable end, Power circuit: connector 2 cable(s) 0.01...0.02 in (4...16 mm) - cable stiffness: flexible - with cable end, Power circuit: connector 1 cable(s) 0.01...0.08 in (4...50 mm) - cable stiffness: solid - without cable end, Power circuit: connector 2 cable(s) 0.01...0.04 in (4...25 mm) - cable stiffness: solid - without cable end
  • Range: TeSys
  • Mounting support: Plate, Rail
  • [Ith] conventional free air thermal current: 125 A at <= 140 F (60 C) power circuit, 10 A at <= 140 F (60 C) signaling circuit
  • System Voltage: <= 690 V AC power circuit, <= 300 V DC 25...400 Hz power circuit
  • Operating rate: 3600 cyc/h at <= 140 F (60 C)
  • Product name: TeSys D
  • [Uc] control circuit voltage: 110 V AC 50/60 Hz
  • Electrical durability: 0.8 Mcycles 125 A AC-1 at Ue <= 440 V, 1.5 Mcycles 80 A AC-3 at Ue <= 440 V
  • Insulation resistance: > 10 MOhm signaling circuit
  • motor power kW: 22 kW at 220...230 V AC 50/60 Hz AC-3, 37 kW at 380...400 V AC 50/60 Hz AC-3, 45 kW at 660...690 V AC 50/60 Hz AC-3, 45 kW at 415...440 V AC 50/60 Hz AC-3, 55 kW at 500 V AC 50/60 Hz AC-3, 45 kW at 1000 V AC 50/60 Hz AC-3, 15 kW at 400 V AC 50/60 Hz AC-4
  • [Ie] rated operational current: 125 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit, 80 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit
  • Utilization category: AC-1, AC-3, AC-4
  • Control circuit voltage limits: 0.85...1.1 Uc operational at 131 F (55 C), AC 60 Hz, 0.3...0.6 Uc drop-out at 131 F (55 C), AC 50/60 Hz, 0.8...1.1 Uc operational at 55 C, AC 50 Hz
  • Poles description: 3P
  • Overvoltage category: III
  • Operating time: 20...35 ms closing, 6...20 ms opening
  • Associated fuse rating: 160 A gG at <= 690 V coordination type 2 power circuit, 200 A gG at <= 690 V coordination type 1 power circuit, 10 A gG signaling circuit conforming to IEC 60947-5-1
  • Control circuit type: AC 50/60 Hz
  • Coil technology: Without built-in suppressor module
  • inrush power in VA: 245 VA at 68 F (20 C) (cos ? 0.75) 60 Hz, 245 VA at 68 F (20 C) (cos ? 0.75) 50 Hz
  • Pollution degree: 3
  • Product or component type: Contactor
  • hold-in power consumption in VA: 26 VA at 68 F (20 C) (cos ? 0.3) 60 Hz, 26 VA at 68 F (20 C) (cos ? 0.3) 50 Hz
  • Ambient air temperature for operation: 23...140 F (-5...60 C)
  • Heat dissipation: 6...10 W at 50/60 Hz
  • Ambient air temperature for storage: -76...176 F (-60...80 C)
  • Contactor application: Motor control, Resistive load
  • Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1, Type mirror contact (1 NC) conforming to IEC 60947-4-1
  • Permissible ambient air temperature around the device: -40...158 F (-40...70 C) at Uc
  • Signaling circuit frequency: 25...400 Hz
  • Minimum switching current: 5 mA signaling circuit
  • Fire resistance: 1562 F (850 C) conforming to IEC 60695-2-1
  • Pole contact composition: 3 NO
  • Minimum switching voltage: 17 V signaling circuit
  • Flame retardance: V1 conforming to UL 94
  • Non-overlap time: 1.5 ms on de-energisation (between NC and NO contact), 1.5 ms on energisation (between NC and NO contact)
  • Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 Hz, Shocks contactor open 8 Gn for 11 ms, Vibrations contactor closed 3 Gn, 5...300 Hz, Shocks contactor closed 10 Gn for 11 ms
  • Power range: 15...25 kW 200...240 V 3 phases, 30...50 kW 380...440 V 3 phases, 30...50 kW 480...500 V 3 phases, 55...100 kW 480...500 V 3 phases
  • Motor power hp: 20 hp at 200/208 V AC 50/60 Hz 3 phases motors, 7.5 hp at 115 V AC 50/60 Hz 1 phase motors, 15 hp at 230/240 V AC 50/60 Hz 1 phase motors, 25 hp at 230/240 V AC 50/60 Hz 3 phases motors, 60 hp at 460/480 V AC 50/60 Hz 3 phases motors, 60 hp at 575/600 V AC 50/60 Hz 3 phases motors
  • Motor starter type: Direct on-line contactor
  • Contactor coil voltage: 110 V AC standard
  • Auxiliary contact composition: 1 NO + 1 NC
  • Irms rated making capacity: 1100 A at 440 V power circuit conforming to IEC 60947, 140 A AC signaling circuit conforming to IEC 60947-5-1, 250 A DC signaling circuit conforming to IEC 60947-5-1
  • Rated breaking capacity: 1100 A at 440 V power circuit conforming to IEC 60947
  • [Icw] rated short-time withstand current: 135 A <= 104 F (40 C) 10 min power circuit, 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 140 A 100 ms signaling circuit, 640 A <= 104 F (40 C) 10 s power circuit, 990 A <= 104 F (40 C) 1 s power circuit, 320 A <= 104 F (40 C) 1 min power circuit
  • Average impedance: 0.8 mOhm at 50 Hz - Ith 125 A power circuit
  • Power dissipation per pole: 5.1 W AC-3, 12.5 W AC-1
  • Protective cover: With
  • Product certifications: DNV, CCC, GL, CSA, UL, BV, LROS (Lloyds register of shipping), GOST, RINA
  • Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1D80F7 . Santa Clara Systems carries 10,296 items from Telemecanique.
  • Tesys D Contactor - 3p(3 No) - Ac-3 - <= 440 V 80 A - 110 V Ac 50/60 Hz Coil

Alternates

    Common Typos

    • 1C1D80F7
    • 1C1D8OF7
    • 1C1DB0F7
    • 1C1DBOF7
    • 1CID80F7
    • 1CID8OF7
    • 1CIDB0F7
    • 1CIDBOF7
    • 1CLD80F7
    • 1CLD8OF7
    • 1CLDB0F7
    • 1CLDBOF7
    • IC1D80F7
    • IC1D8OF7
    • IC1DB0F7
    • LC1D8OF7
    • LC1DB0F7
    • LC1DBOF7
    • LCID80F7
    • LCID8OF7
    • LCIDB0F7
    • LCIDBOF7
    • LCLD80F7
    • LCLD8OF7
    • LCLDB0F7
    • LCLDBOF7

    Appended Numbers

    • LC1D80F7-A
    • LC1D80F7-B
    • LC1D80F7-C
    • LC1D80F7-D
    • LC1D80F7-E
    • LC1D80F7-F
    • LC1D80F7-G
    • LC1D80F7-H
    • LC1D80F7-I
    • LC1D80F7-J
    • LC1D80F7-K
    • LC1D80F7-L
    • LC1D80F7-M
    • LC1D80F7-N
    • LC1D80F7-O
    • LC1D80F7-P
    • LC1D80F7-Q
    • LC1D80F7-R
    • LC1D80F7-S
    • LC1D80F7-T
    • LC1D80F7-U
    • LC1D80F7-V
    • LC1D80F7-W
    • LC1D80F7-X
    • LC1D80F7-Y
    • LC1D80F7-Z

    More Products Like This

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo