- Description: power base - TeSys U - 12 A - 110...220 V DC screw clamps control
- Product weight: 2.8 lb(US) (1.27 kg)
- IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1IP20 other faces conforming to IEC 60947-1IP40 front panel outside connection zone conforming to IEC 60947-1
- Standards: CSA C22.2 No 14 type EEN 60947-6-2IEC 60947-6-2UL 508 type E with phase barrier
- Device short name: LU2B
- Width: 1.77 in (45 mm)
- Height: 8.82 in (224 mm)
- Depth: 4.96 in (126 mm)
- Protective treatment: TH conforming to IEC 60068
- [Ui] rated insulation voltage: 600 V conforming to CSA C22.2 No 14600 V conforming to UL 508690 V conforming to IEC 60947-1 3
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 15000000 cycles
- Tightening torque: Control circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) flatControl circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) Philips no 1Power circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) flatPower circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) Philips No 2
- Connections - terminals: Power circuit: screw clamp terminals 2 cable 0...0.01 in² (1.5...6 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: rigid - without cable endControl circuit: screw clamp terminals 2 cable 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 2 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: rigid - without cable endPower circuit: screw clamp terminals 1 cable 0...0.02 in² (1...10 mm²) - cable stiffness: rigid - without cable endPower circuit: screw clamp terminals 1 cable 0...0.01 in² (1...6 mm²) - cable stiffness: flexible - with cable endPower circuit: screw clamp terminals 1 cable 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - without cable endPower circuit: screw clamp terminals 2 cable 0...0.01 in² (1...6 mm²) - cable stiffness: flexible - with cable endPower circuit: screw clamp terminals 2 cable 0...0.01 in² (1...6 mm²) - cable stiffness: rigid - without cable end
- Range: TeSys
- [Ith] conventional free air thermal current: 12:00 AM
- System Voltage: 230 V440 V500 V690 V
- Operating rate: 60 cyc/mn
- [Uc] control circuit voltage: 110...220 V DC110...240 V AC 50/60 Hz
- Product name: TeSys U
- Shock resistance: 10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27
- Vibration resistance: 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-274 gn 5...300 Hz power poles closed conforming to IEC 60068-2-27
- [Ie] rated operational current: 12 A at <= 440 V12 A at 500 V9 A at 690 V
- Utilization category: AC-44AC-43AC-41
- Control circuit voltage limits: 55 V 110...220 V DC drop-out55 V 110...240 V AC drop-out88...242 V 110...220 V DC in operation88...264 V 110...240 V AC in operation
- Poles description: 3P
- Operating time: 150 ms with change of direction power circuit35 ms opening control circuit50 ms closing control circuit75 ms without change of direction power circuit
- Device application: Motor
- Suitability for isolation: Yes
- Utilisation category: AC-44 AC-43 AC-41
- Product or component type: Reversing power base
- Auxiliary contact composition: 1 NO + 1 NC
- Heat dissipation: 2 W for control circuit with LUCA, LUCB, LUCC, LUCD1.7 W for control circuit with LUCM
- Auxiliary contacts type: Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1
- Immunity to micro breaks: 3 ms
- Immunity to voltage dips: 70 % 500 ms conforming to IEC 61000-4-11
- Network frequency: 40...60 Hz
- Product certifications: DNVCSAGOSTATEXULABSBVLROS (Lloyds register of shipping)ASEFACCCGL
- [Ics] rated service breaking capacity: 10 kA 500 V4 kA 690 V50 kA 230 V50 kA 440 V
- Typical current consumption: 1000 mA at 110...220 V DC I maximum while closing1000 mA at 110...240 V AC I maximum while closing
- Ambient air temperature for operation: -13...140 °F (-25...60 °C) with LUCM-13...158 °F (-25...70 °C) with LUCA, LUCB, LUCC, LUCD
- Inrush restraint duration: 15 ms DC network25 ms AC network 50/60 Hz
- Ambient air temperature for storage: -40...185 °F (-40...85 °C)
- Safety reliability level: B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Fire resistance: 1202 °F (650 °C) conforming to IEC 60695-2-121760 °F (960 °C) parts supporting live components conforming to IEC 60695-2-12
- Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2
- Resistance to radiated fields: 9.14 V/yd (10 V/m) 3 conforming to IEC 61000-4-3
- Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
- Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
- Non-dissipating shock wave: 1 kV serial mode conforming to IEC 60947-6-22 kV common mode conforming to IEC 60947-6-2
- Immunity to radio electric fields: 10 V conforming to IEC 61000-4-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LU2B12FU . Santa Clara Systems carries 10,632 items from Telemecanique.
- Power Base - Tesys U - 12 A - 110...220 V Dc Screw Clamps Control
Alternates
Common Typos
- 1U2B12FU
- 1U2B1ZFU
- 1U2BI2FU
- LU2812FU
- LU281ZFU
- LU28I2FU
- LU28IZFU
- LU28L2FU
- LU28LZFU
- LU2B1ZFU
- LU2BI2FU
- LU2BIZFU
- LU2BL2FU
- LU2BLZFU
- LUZ812FU
- LUZ81ZFU
- LUZ8I2FU
- LUZ8IZFU
- LUZ8L2FU
- LUZ8LZFU
- LUZB12FU
- LUZB1ZFU
- LUZBI2FU
- LUZBIZFU
- LUZBL2FU
- LUZBLZFU
Appended Numbers
- LU2B12FU-A
- LU2B12FU-B
- LU2B12FU-C
- LU2B12FU-D
- LU2B12FU-E
- LU2B12FU-F
- LU2B12FU-G
- LU2B12FU-H
- LU2B12FU-I
- LU2B12FU-J
- LU2B12FU-K
- LU2B12FU-L
- LU2B12FU-M
- LU2B12FU-N
- LU2B12FU-O
- LU2B12FU-P
- LU2B12FU-Q
- LU2B12FU-R
- LU2B12FU-S
- LU2B12FU-T
- LU2B12FU-U
- LU2B12FU-V
- LU2B12FU-W
- LU2B12FU-X
- LU2B12FU-Y
- LU2B12FU-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier