- Description: AL26-22-00 220V DC Contactor
- Product ID: 1SBL243501R8800
- Extended Product Type: 1SBL243501R8800
- Product Net Weight: 0.750 kg
- Product Net Width: 54 mm
- Product Net Height: 90 mm
- Product Net Depth: 110.6 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Ambient Air Temperature: Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 C Near Contactor for Operation in Free Air (Uc) -40 ... +70 C Close to Contactor for Storage -60 ... +80 C
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
- Terminal Type: Screw Terminals
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 0
- Mechanical Durability: 10 million
- Connecting Capacity Main Circuit: Rigid Cable 1.5 ... 6 mm Flexible with Cable End 0.75 ... 4 mm
- GOST Certificate: GOST_POCCFRME77B07175
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): DC Operation 220 V
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Connecting Capacity Auxiliary Circuit: Rigid Cable 1 ... 4 mm Flexible with Cable End 0.75 ... 2.5 mm
- Operate Time: Between Coil Energization and NO Contact Closing 55 ... 110 ms Between Coil De-energization and NO Contact Opening 12 ... 18 ms Between Coil De-energization and NC Contact Closing 18 ... 28 ms Between Coil Energization and NC Contact Opening 25 ... 75 ms
- Number of Main Contacts NO: 2
- Number of Main Contacts NC: 2
- Short-Circuit Protective Devices: gG Type Fuses 50 A
- Coil Consumption: Average Holding Value, from Warm State 3.5 W Average Pull-in Value, from Cold State 3.5 W
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) C
- Connecting terminals (delivered in open position) Main poles: M 4 (+,-) pozidriv 2 screw with cable clamp
- EAN: 3471522284884
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Package Level 1 Width: 100 mm
- Package Level 1 Length: 134 mm
- Package Level 1 Height: 62 mm
- Package Level 1 Gross Weight: 0.75 kg
- Package Level 1 EAN: 3471522284884
- Package Level 2 Units: 20 piece
- Package Level 3 Units: 384 piece
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 45 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 45 A (690 V) 55 C 40 A (690 V) 70 C 32 A
- Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 210 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 45 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 90 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 400 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 110 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: A 20 g Open, Shock Direction: A 10 g Closed, Shock Direction: B1 15 g Open, Shock Direction: B1 5 g Shock Direction: B2 10 g Closed, Shock Direction: C1 20 g Open, Shock Direction: C1 8 g Closed, Shock Direction: C2 14 g Open, Shock Direction: C2 8 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: 1SBC101007M5501
- CCC Certificate: CCC_2004010304112231
- Data Sheet, Technical Information: 1SBC100122C0202_Ch02
- Declaration of Conformity - CE: 1SBD250804U1000
- RoHS Information: 1SBD350055R1000
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AL26-22-00-88 . Santa Clara Systems carries 36,687 items from ABB.
- Al26 4-Pole Contactors Are Mainly Used For Controlling Non-Inductive Or Slightly Inductive Loads (I.e. Resistance Furnaces...) And Generally For Controlling Power Circuits Up To 690 V Ac And 440 V Dc. The Contactors Can Also Be Used For Many Other Applications Such Lighting... The Al... Series 4-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 2 N.o. + 2 N.c. Main Poles
- Al26 4-Pole Contactors Are Mainly Used For Controlling Non-Inductive Or Slightly Inductive Loads (I.e. Resistance Furnaces...) And Generally For Controlling Power Circuits Up To 690 V Ac And 440 V Dc. The Contactors Can Also Be Used For Many Other Applications Such Lighting... The Al... Series 4-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 2 N.o. + 2 N.c. Main Poles
- Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Dc Operated With Solid Core Magnet Circuit. The Polarity On The Coil Terminals (A1+ And A2-) Must Be Respected - Accessories: A Wide Range Of Accessories Is Available. Al... Contactors Are Fitted With Low Consumption Dc Coils And Are Suitable For A Direct Control By Plc Outputs.
Alternates
- 1SBL243501R8800
- AL26 22 00 88
- AL26220088
Common Typos
- AL26-22-00-8B
- AL26-22-00-B8
- AL26-22-00-BB
- AL26-22-0O-88
- AL26-22-0O-8B
- AL26-22-0O-B8
- AL26-22-0O-BB
- AL26-22-O0-88
- AL26-22-O0-8B
- AL26-22-O0-B8
- AL26-22-O0-BB
- AL26-22-OO-88
- AL26-22-OO-8B
- AL26-22-OO-B8
- AL26-22-OO-BB
- AL26-2Z-00-88
- AL26-2Z-00-8B
- AL26-2Z-00-B8
- AL26-2Z-00-BB
- AL26-2Z-0O-88
- AL26-2Z-0O-8B
- AL26-2Z-0O-B8
- AL26-2Z-0O-BB
- AL26-2Z-O0-88
- AL26-2Z-O0-8B
- AL26-2Z-O0-B8
Appended Numbers
- AL26-22-00-88-A
- AL26-22-00-88-B
- AL26-22-00-88-C
- AL26-22-00-88-D
- AL26-22-00-88-E
- AL26-22-00-88-F
- AL26-22-00-88-G
- AL26-22-00-88-H
- AL26-22-00-88-I
- AL26-22-00-88-J
- AL26-22-00-88-K
- AL26-22-00-88-L
- AL26-22-00-88-M
- AL26-22-00-88-N
- AL26-22-00-88-O
- AL26-22-00-88-P
- AL26-22-00-88-Q
- AL26-22-00-88-R
- AL26-22-00-88-S
- AL26-22-00-88-T
- AL26-22-00-88-U
- AL26-22-00-88-V
- AL26-22-00-88-W
- AL26-22-00-88-X
- AL26-22-00-88-Y
- AL26-22-00-88-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier