• Telemecanique LC1F265F7 Barcode

LC1F265F7

Get a Quote

Current response time:

By 5AM PT on Tuesday
  • Description: TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 265 A - coil 110 V AC
  • Product weight: 16.4 lb(US) (7.44 kg)
  • IP degree of protection: IP20 front face with shrouds (ordered separately) conforming to IEC 60529IP20 front face with shrouds (ordered separately) conforming to VDE 0106
  • Standards: IEC 60947-1EN 60947-4-1JIS C8201-4-1EN 60947-1IEC 60947-4-1
  • Device short name: LC1F
  • Width: 7.93 in (201.5 mm)
  • Height: 7.99 in (203 mm)
  • Depth: 8.39 in (213 mm)
  • Protective treatment: TH
  • [Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C
  • [Uimp] rated impulse withstand voltage: 8 kV
  • Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
  • Mechanical durability: 10 Mcycles
  • Tightening torque: Power circuit: 309.73 lbf.in (35 N.m)Control circuit: 10.62 lbf.in (1.2 N.m)
  • Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable endPower circuit: connector 1 cable(s) 0.37 in² (240 mm²)Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endPower circuit: lugs-ring terminals 1 cable(s) 0.37 in² (240 mm²)Power circuit : bolted connectionPower circuit : bar 2 x (32 x 4 mm)
  • Range: TeSys
  • Mounting support: Plate
  • [Ith] conventional free air thermal current: 350 A at <= 104 °F (40 °C)
  • System Voltage: <= 1000 V AC 50/60 Hz<= 460 V DC
  • Operating rate: 2400 cyc/h at <= 131 °F (55 °C)
  • Product name: TeSys F
  • [Uc] control circuit voltage: 110 V AC 40...400 Hz
  • motor power kW: 132 kW at 380...400 V AC 50/60 Hz AC-3140 kW at 415 V AC 50/60 Hz AC-3140 kW at 440 V AC 50/60 Hz AC-3160 kW at 500 V AC 50/60 Hz AC-3147 kW at 1000 V AC 50/60 Hz AC-375 kW at 220...230 V AC 50/60 Hz AC-351 kW at 400 V AC 50/60 Hz AC-4160 kW at 660...690 V AC 50/60 Hz AC-3
  • [Ie] rated operational current: 350 A (<= 104 °F (40 °C)) at <= 440 V AC AC-1265 A (<= 131 °F (55 °C)) at <= 440 V AC AC-3
  • Utilization category: AC-4AC-3AC-1
  • Control circuit voltage limits: 0.85...1.1 Uc at 131 °F (55 °C) operational 40...400 Hz0.15...0.2 Uc at 131 °F (55 °C) drop-out 40...400 Hz
  • Poles description: 3P
  • Overvoltage category: III
  • Operating time: 100...170 ms opening40...65 ms closing
  • Associated fuse rating: 315 A aM at <= 440 V400 A gG at <= 440 V
  • Product or component type: Contactor
  • Ambient air temperature for operation: 23...131 °F (-5...55 °C)
  • Rated breaking capacity: 2120 A conforming to IEC 60947-4-1
  • Ambient air temperature for storage: -76...176 °F (-60...80 °C)
  • Contactor application: Motor controlResistive load
  • [Icw] rated short-time withstand current: 2200 A <= 104 °F (40 °C) 10 s1230 A <= 104 °F (40 °C) 30 s950 A <= 104 °F (40 °C) 1 min620 A <= 104 °F (40 °C) 3 min480 A <= 104 °F (40 °C) 10 min
  • Permissible ambient air temperature around the device: -40...158 °F (-40...70 °C)
  • Average impedance: 0.3 mOhm at 50 Hz - Ith 350 A
  • Mechanical robustness: Vibrations contactor closed 5 Gn, 5...300 HzVibrations contactor open 2 Gn, 5...300 HzShocks contactor closed 15 Gn for 11 msShocks contactor open 6 Gn for 11 ms
  • Pole contact composition: 3 NO
  • Power dissipation per pole: 21 W AC-337 W AC-1
  • Product certifications: BVABSCBRMRoSULLROS (Lloyds register of shipping)DNVRINACSA
  • inrush power in VA: 650 VA at 68 °F (20 °C) (cos ? 0.9) 40...400 Hz
  • hold-in power consumption in VA: 10 VA at 68 °F (20 °C) (cos ? 0.9) 40...400 Hz
  • Heat dissipation: 8 W
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1F265F7 . Santa Clara Systems carries 10,454 items from Telemecanique.
  • Tesys F Contactor - 3p (3 No) - Ac-3 - <= 440 V 265 A - Coil 110 V Ac

Alternates

    Common Typos

    • 1C1F265F7
    • 1C1F26SF7
    • 1C1F2G5F7
    • LC1F26SF7
    • LC1F2G5F7
    • LC1F2GSF7
    • LC1FZ65F7
    • LC1FZ6SF7
    • LC1FZG5F7
    • LC1FZGSF7
    • LCIF265F7
    • LCIF26SF7
    • LCIF2G5F7
    • LCIF2GSF7
    • LCIFZ65F7
    • LCIFZ6SF7
    • LCIFZG5F7
    • LCIFZGSF7
    • LCLF265F7
    • LCLF26SF7
    • LCLF2G5F7
    • LCLF2GSF7
    • LCLFZ65F7
    • LCLFZ6SF7
    • LCLFZG5F7
    • LCLFZGSF7

    Appended Numbers

    • LC1F265F7-A
    • LC1F265F7-B
    • LC1F265F7-C
    • LC1F265F7-D
    • LC1F265F7-E
    • LC1F265F7-F
    • LC1F265F7-G
    • LC1F265F7-H
    • LC1F265F7-I
    • LC1F265F7-J
    • LC1F265F7-K
    • LC1F265F7-L
    • LC1F265F7-M
    • LC1F265F7-N
    • LC1F265F7-O
    • LC1F265F7-P
    • LC1F265F7-Q
    • LC1F265F7-R
    • LC1F265F7-S
    • LC1F265F7-T
    • LC1F265F7-U
    • LC1F265F7-V
    • LC1F265F7-W
    • LC1F265F7-X
    • LC1F265F7-Y
    • LC1F265F7-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo