- Description: AM185-30-22 110-125V Contactor
- Product ID: 1SFL498029R7822
- Extended Product Type: 1SFL498029R7822
- Product Net Weight: 2.000 kg
- Product Net Width: 142.0 mm
- Product Net Height: 196.0 mm
- Product Net Depth: 160.0 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 C Close to Contactor for Storage -40+70 C
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Terminal Type: Main Circuit: Bars
- Rated Frequency (f): Main Circuit 50/60 Hz
- Number of Auxiliary Contacts NO: 2
- Number of Auxiliary Contacts NC: 2
- Mechanical Durability: 5 million
- Connecting Capacity Main Circuit: Rigid Al-Cable 25150 mm Bar 24 mm Rigid Cu-Cable 6185 mm
- Maximum Operating Voltage UL/CSA: Main Circuit 600 V
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): 60 Hz 110 ... 125 V 50 Hz 110 ... 125 V DC Operation 110 ... 125 V
- Maximum Mechanical Switching Frequency: 300 cycles per hour
- Connecting Capacity Auxiliary Circuit: Solid 2x14 mm Flexible with Insulated Ferrule 2x0.752.5 mm Stranded 2x14 mm Flexible 2x0.752.5 mm Flexible with Ferrule 2x0.752.5 mm
- Operate Time: Between Coil Energization and NO Contact Closing 50 90 ms Between Coil De-energization and NO Contact Opening 43 53 ms Between Coil De-energization and NC Contact Closing 40 50 ms Between Coil Energization and NC Contact Opening 45 85 ms
- Number of Main Contacts NO: 3
- GL Certificate: GL_20261-04HH
- Number of Main Contacts NC: 0
- Short-Circuit Protective Devices: gG Type Fuses 160 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1600 A
- Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 600 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 35 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 40 V·A
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at 70 C) C
- Connecting terminals (delivered in open position) Main poles: Flat type c/w screws and bolts
- Horsepower Rating UL/CSA: (208 V AC) Three Phase 50 Hp (440 ... 480 V AC) Three Phase 125 Hp (550 ... 600 V AC) Three Phase 150 Hp (220 ... 240 V AC) Three Phase 60 Hp (200 V AC) Three Phase 50 Hp
- EAN: 7320500339107
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Package Level 1 Width: 170 mm
- Package Level 1 Length: 180 mm
- Package Level 1 Height: 245 mm
- Package Level 1 Gross Weight: 2 kg
- Package Level 1 EAN: 7320500339107
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 275 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 55 C 250 A (690 V) 40 C 275 A (1000 V) 40 C 200 A (1000 V) 55 C 200 A (690 V) 70 C 180 A (1000 V) 70 C 180 A
- Rated Operational Current AC-3 (I<sub>e</sub>): (1000 V) 55 C 95 A (690 V) 55 C 170 A (415 V) 55 C 185 A (220 / 230 / 240 V) 55 C 185 A (440 V) 55 C 185 A (380 / 400 V) 55 C 185 A (500 V) 55 C 170 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (500 V) 110 kW (220 / 230 / 240 V) 55 kW (690 V) 132 kW (380 / 400 V) 90 kW (440 V) 90 kW (415 V) 90 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour
- Rated Operational Current DC-1 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 275 A (220 V) 3 Poles in Series, 40 C 275 A
- Rated Operational Current DC-3 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 275 A (220 V) 3 Poles in Series, 40 C 275 A
- Rated Operational Current DC-5 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 275 A (220 V) 3 Poles in Series, 40 C 275 A
- Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 5 g Shock Direction: C2 5 g Shock Direction: C1 5 g Shock Direction: B2 5 g Shock Direction: B1 5 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: 1SFC101024M5501
- Data Sheet, Technical Information: 1SBC100122C0202
- Declaration of Conformity - CE: 1SFA1-89
- RINA Certificate: ELE060313XG/002
- RMRS Certificate: RMRS_12-03683-315
- RoHS Information: 1SFC101046D0203
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- UNSPSC: 39121529
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AM185-30-22-78 . Santa Clara Systems carries 36,687 items from ABB.
- Control Voltage 110-125 V
- Ac/dc Latch
- A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
- Isolation
- By-Pass And Distribution Application Up To Max 690 V. Magnetically Latch
Alternates
- 1SFL498029R7822
- AM185-30-78
- AM185 30 78
- AM1853078
Common Typos
- AM185-30-22-7B
- AM185-30-2Z-78
- AM185-30-2Z-7B
- AM185-30-Z2-78
- AM185-30-Z2-7B
- AM185-30-ZZ-78
- AM185-30-ZZ-7B
- AM185-3O-22-78
- AM185-3O-22-7B
- AM185-3O-2Z-78
- AM185-3O-2Z-7B
- AM185-3O-Z2-78
- AM185-3O-Z2-7B
- AM185-3O-ZZ-78
- AM185-3O-ZZ-7B
- AM18S-30-22-78
- AM18S-30-22-7B
- AM18S-30-2Z-78
- AM18S-30-2Z-7B
- AM18S-30-Z2-78
- AM18S-30-Z2-7B
- AM18S-30-ZZ-78
- AM18S-30-ZZ-7B
- AM18S-3O-22-78
- AM18S-3O-22-7B
- AM18S-3O-2Z-78
Appended Numbers
- AM185-30-22-78-A
- AM185-30-22-78-B
- AM185-30-22-78-C
- AM185-30-22-78-D
- AM185-30-22-78-E
- AM185-30-22-78-F
- AM185-30-22-78-G
- AM185-30-22-78-H
- AM185-30-22-78-I
- AM185-30-22-78-J
- AM185-30-22-78-K
- AM185-30-22-78-L
- AM185-30-22-78-M
- AM185-30-22-78-N
- AM185-30-22-78-O
- AM185-30-22-78-P
- AM185-30-22-78-Q
- AM185-30-22-78-R
- AM185-30-22-78-S
- AM185-30-22-78-T
- AM185-30-22-78-U
- AM185-30-22-78-V
- AM185-30-22-78-W
- AM185-30-22-78-X
- AM185-30-22-78-Y
- AM185-30-22-78-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier