- Description: N62E 200V 50Hz / 200-220V 60Hz Contactor Relay
- Product ID: 1SBH141001R7562
- Extended Product Type: 1SBH141001R7562
- Product Net Weight: 0.400 kg
- Product Net Width: 44 mm
- Product Net Height: 74 mm
- Product Net Depth: 107 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
- Ambient Air Temperature: Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 C Near Contactor for Operation in Free Air (Uc) -40 ... +70 C Close to Contactor for Storage -60 ... +80 C
- Standards: Devices complying with international standards IEC 947-5-1 / 947-4-1 and European standards EN 60 947-5-1 / 60 947-4-1. Electromagnetic compatibility (EMC) according to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
- Terminal Type: Screw Terminals
- Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
- Number of Auxiliary Contacts NO: 4
- Number of Auxiliary Contacts NC: 2
- Mechanical Durability: > 20 million
- GOST Certificate: GOST_POCCFRME01B03022
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 200 V 60 Hz 200 220 V
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Mechanical Switching Frequency: 6000 cycles per hour
- Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
- Operate Time: Between Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil De-energization and NC Contact Closing 9 ... 16 ms Between Coil Energization and NC Contact Opening 7 ... 21 ms
- GL Certificate: DNV-GL_TAE00000TY
- Short-Circuit Protective Devices: gG Type Fuses 10 A
- Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 50 Hz 70 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 80 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 8 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 2 W Holding at Max. Rated Control Circuit Voltage 50 Hz 8 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 2 W Average Holding Value 50 Hz 8 V·A Average Holding Value 50 Hz 2 W Average Holding Value 60 Hz 8 V·A Average Holding Value 60 Hz 2 W Average Pull-in Value 50 Hz 70 V·A Average Pull-in Value 60 Hz 80 V·A
- Coil Operating Limits: (acc. to IEC 60947-5-1) 0.85 ... 1.1 x Uc (at 55 C) C
- EAN: 3471522015754
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Package Level 1 Width: 78 mm
- Package Level 1 Length: 110 mm
- Package Level 1 Height: 46 mm
- Package Level 1 Gross Weight: 0.4 kg
- Package Level 1 EAN: 3471522015754
- Package Level 2 Units: 48 piece
- Package Level 3 Units: 576 piece
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-5-1, q = 40 C 16 A
- Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I<sub>cw</sub>): for 0.1 s 140 A for 1 s 100 A
- Rated Operational Current DC-13 (I<sub>e</sub>): (125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A
- Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: FPTC407721P0001
- BV Certificate: BV_2634H09651C0
- CB Certificate: CB_FR_602227B
- CCC Certificate: CCC_2003010304088236
- CSA Certificate: CSA_1041746
- cUL Certificate: UL_110105E48139A
- Data Sheet, Technical Information: 1SBC100122C0202_Ch03
- Declaration of Conformity - CE: 1SBD250808U1000
- DNV Certificate: DNV-GL_TAE00000TY
- LR Certificate: LRS_9830010E2
- RINA Certificate: RINA_ELE128713XG002
- RMRS Certificate: RMRS_0507015250
- RoHS Information: 1SBD350056R1000
- UL Certificate: UL_110105E48139A
- ETIM 4: EC000196 - Contactor relay
- ETIM 5: EC000196 - Contactor relay
- ETIM 6: EC000196 - Contactor relay
- UNSPSC: 39121500
- Object Classification Code: K
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on N62E-75 . Santa Clara Systems carries 36,836 items from ABB.
- N... Contactor Relays Are Used For Switching Auxiliary Circuits And Control Circuits - Poles: 8-Pole Contactor Relays (Mechanically Linked Contact Elements Available) The Width Of 8-Pole Devices Is Identical To That Of 4-Pole Devices Only The Depth Is Increased - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available. <Br /> Only The Depth Is Increased<Br/>- Control Circuit: Ac Operated With Laminated Magnet Circuit<Br/>- Accessories: A Wide Range Of Accessories Is Available.
Alternates
- 1SBH141001R7562
- N62E 75
- N62E75
Common Typos
- N62E-7S
- N6ZE-75
- N6ZE-7S
- NG2E-75
- NG2E-7S
- NGZE-75
- NGZE-7S
Appended Numbers
- N62E-75-A
- N62E-75-B
- N62E-75-C
- N62E-75-D
- N62E-75-E
- N62E-75-F
- N62E-75-G
- N62E-75-H
- N62E-75-I
- N62E-75-J
- N62E-75-K
- N62E-75-L
- N62E-75-M
- N62E-75-N
- N62E-75-O
- N62E-75-P
- N62E-75-Q
- N62E-75-R
- N62E-75-S
- N62E-75-T
- N62E-75-U
- N62E-75-V
- N62E-75-W
- N62E-75-X
- N62E-75-Y
- N62E-75-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier