• Telemecanique LC1K0910G7 TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 120 V AC coil Product Image
  • Telemecanique LC1K0910G7 TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 120 V AC coil Product Image
  • Telemecanique LC1K0910G7 TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 120 V AC coil Product Image
  • Telemecanique LC1K0910G7 Barcode

LC1K0910G7

產品概述:

  • Range of product: TeSys K
  • Device short name: LC1K
  • Protective treatment: TC conforming to IEC 60068, TC conforming to DIN 50016
  • Operating altitude: 6561.68 ft. (2000 m) without derating in temperature
  • Range: TeSys
諮價諮詢

Current response time:

By 5AM PT on Thursday
  • 介紹: TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 120 V AC coil
  • Range of product: TeSys K
  • Device short name: LC1K
  • Protective treatment: TC conforming to IEC 60068, TC conforming to DIN 50016
  • Operating altitude: 6561.68 ft. (2000 m) without derating in temperature
  • Range: TeSys
  • [Ith] conventional free air thermal current: 20 A at <= 122 F (50 C) power circuit, 10 A at <= 122 F (50 C) signaling circuit
  • Operating rate: 3600 cyc/h
  • Product name: TeSys K
  • [Uc] control circuit voltage: 120 V AC 50/60 Hz
  • Insulation resistance: > 10 MOhm signaling circuit
  • motor power kW: 2.2 kW at 400 V AC 50/60 Hz AC-4, 2.2 kW at 220...230 V AC 50/60 Hz AC-3, 4 kW at 380...415 V AC 50/60 Hz AC-3, 4 kW at 440 V AC 50/60 Hz AC-3, 4 kW at 480 V AC 50/60 Hz AC-3, 4 kW at 500...600 V AC 50/60 Hz AC-3, 4 kW at 660...690 V AC 50/60 Hz AC-3
  • [Ie] rated operational current: 9 A at <= 440 V AC AC-3 power circuit, 20 A (<= 122 F (50 C)) at <= 440 V AC AC-1 power circuit, 16 A (<= 158 F (70 C)) at 690 V AC AC-1 power circuit
  • Utilization category: AC-4, AC-1, AC-3
  • Control circuit voltage limits: 0.2...0.75 Uc at <= 122 F (50 C) drop-out, 0.8...1.15 Uc at <= 122 F (50 C) operational
  • Poles description: 3P
  • Overvoltage category: III
  • Operating time: 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing
  • Associated fuse rating: 25 A gG at <= 440 V power circuit, 25 A aM power circuit, 10 A gG signaling circuit conforming to IEC 60947, 10 A gG signaling circuit conforming to VDE 0660
  • Control circuit type: AC 50/60 Hz
  • Product certifications: UL, CSA
  • Product or component type: Contactor
  • Pole contact composition: 3 NO
  • Flame retardance: V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
  • Device application: Control
  • Contactor application: Resistive load, Motor control
  • Auxiliary contact composition: 1 NO
  • Irms rated making capacity: 110 A AC power circuit conforming to NF C 63-110, 110 A AC power circuit conforming to IEC 60947, 110 A AC signaling circuit conforming to IEC 60947
  • Rated breaking capacity: 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
  • Average impedance: 3 mOhm at 50 Hz - Ith 20 A power circuit
  • inrush power in VA: 30 VA at 68 F (20 C)
  • hold-in power consumption in VA: 4.5 VA at 68 F (20 C)
  • Heat dissipation: 1.3 W
  • Auxiliary contacts type: Type instantaneous (1 NO)
  • Signaling circuit frequency: <= 400 Hz
  • Minimum switching current: 5 mA signaling circuit
  • Minimum switching voltage: 17 V signaling circuit
  • Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • Non overlap distance: 0.02 in (0.5 mm)
  • Mechanical robustness: Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6, Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
Santa Clara Systems專長尋找難覓的零件。請選擇我們積壓庫存,然後儲存在 LC1K0910G7 。Santa Clara Systems大約持有 9,138 項產品 Telemecanique.
  • Tesys K Contactor - 3P - Ac-3 <= 440 V 9 A - 1 No Aux. - 120 V Ac Coil

交替

    常見錯字

    • LC1K091067
    • LC1K091O67
    • LC1K091OG7
    • LC1K09I067
    • LC1K09I0G7
    • LC1K09IO67
    • LC1K09IOG7
    • LC1K09L067
    • LC1K09L0G7
    • LC1K09LO67
    • LC1K09LOG7
    • LC1KO91067
    • LC1KO910G7
    • LC1KO91O67
    • LC1KO91OG7
    • LC1KO9I067
    • LC1KO9I0G7
    • LC1KO9IO67
    • LC1KO9IOG7
    • LC1KO9L067
    • LC1KO9L0G7
    • LC1KO9LO67
    • LC1KO9LOG7
    • LCIK091067
    • LCIK0910G7
    • LCIK091OG7

    附加的數字

    • LC1K0910G7-A
    • LC1K0910G7-B
    • LC1K0910G7-C
    • LC1K0910G7-D
    • LC1K0910G7-E
    • LC1K0910G7-F
    • LC1K0910G7-G
    • LC1K0910G7-H
    • LC1K0910G7-I
    • LC1K0910G7-J
    • LC1K0910G7-K
    • LC1K0910G7-L
    • LC1K0910G7-M
    • LC1K0910G7-N
    • LC1K0910G7-O
    • LC1K0910G7-P
    • LC1K0910G7-Q
    • LC1K0910G7-R
    • LC1K0910G7-S
    • LC1K0910G7-T
    • LC1K0910G7-U
    • LC1K0910G7-V
    • LC1K0910G7-W
    • LC1K0910G7-X
    • LC1K0910G7-Y
    • LC1K0910G7-Z

    更多同類產品

    客戶喜愛的產品

    滿足您所需要的物流

    Late West Coast Shipping Hours
    晚間西海岸物流(下午5點太平洋時間)
    直銷業務與匿名轉運商專家
    專業包裝防靜電
    當天發貨服務
    內部速遞國內和國際
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    與我們合作的客戶

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo