- Description: Standard Control Unit
- Product weight: 0.3 lb(US) (0.135 kg)
- IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1IP20 other faces conforming to IEC 60947-1IP40 front panel outside connection zone conforming to IEC 60947-1
- Standards: CSA C22.2 No 14 type EEN 60947-6-2IEC 60947-6-2UL 508 type E with phase barrier
- Device short name: LUCA
- Protective treatment: TH conforming to IEC 60068
- [Ui] rated insulation voltage: 600 V conforming to CSA C22.2 No 14600 V conforming to UL 508690 V conforming to IEC 60947-1
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
- Operating altitude: 6561.68 ft. (2000 m)
- Range: TeSys
- Product name: TeSys U
- [Uc] control circuit voltage: 110...220 V DC110...240 V AC
- Shock resistance: 10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27
- Vibration resistance: 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-64 gn 5...300 Hz power poles closed conforming to IEC 60068-2-6
- motor power kW: 3 kWat 690 V AC 50/60 Hz1.5 kW at 400...440 V AC 50/60 Hz2.2 kW at 500 V AC 50/60 Hz
- Utilization category: AC-41AC-43AC-44
- Control circuit voltage limits: 88...242 V DC circuit 110...220 V in operation88...264 V AC circuit 110...240 V in operation
- Operating time: 35 ms opening with LUB12 control circuit35 ms opening with LUB32 control circuit50 ms closing with LUB12 control circuit50 ms closing with LUB32 control circuit
- Function available: Protection against phase failure and phase imbalanceProtection against overload and short-circuitManual resetEarth fault protection
- Heat dissipation: 2 W control circuit with LUB123 W control circuit with LUB32
- Mounting mode: Plug-in
- Immunity to micro breaks: 3 ms
- Mounting location: Front side
- Immunity to voltage dips: 70 % 500 ms conforming to IEC 61000-4-11
- Product or component type: Standard control unit
- Product specific application: Basic protection requirements for motor starters: overload and short-circuit
- Typical current consumption: 25 mA at 110...240 V AC I rms sealed with LUB1225 mA at 110...240 V AC I rms sealed with LUB32280 mA at 110...220 V DC I maximum while closing with LUB12280 mA at 110...220 V DC I maximum while closing with LUB32280 mA at 110...240 V AC I maximum while closing with LUB12280 mA at 110...240 V AC I maximum while closing with LUB3235 mA at 110...220 V DC I rms sealed with LUB1235 mA at 110...220 V DC I rms sealed with LUB32
- Product certifications: ABSULBVLROS (Lloyds register of shipping)ATEXCCCCSAGOSTGLDNVASEFA
- Product compatibility: LUFN..LUFC00
- Load type: 3-phase motor - cooling: self-cooled
- Tripping threshold: 14.2 x Ir +/- 20 %
- Ambient air temperature for operation: -13...158 °F (-25...70 °C)
- Thermal protection adjustment range: 1.25...5 A
- Ambient air temperature for storage: -40...185 °F (-40...85 °C)
- Thermal overload class: Class 10 - frequency limit: 40...60 Hz - temperature compensation: -13...158 °F (-25...70 °C) - conforming to IEC 60947-6-2Class 10 - frequency limit: 40...60 Hz - temperature compensation: -13...158 °F (-25...70 °C) - conforming to UL 508Class 20 - frequency limit: 40...60 Hz - temperature compensation: -13...158 °F (-25...70 °C) - conforming to IEC 60947-6-2Class 20 - frequency limit: 40...60 Hz - temperature compensation: -13...158 °F (-25...70 °C) - conforming to UL 508
- Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
- Fire resistance: 1202 °F (650 °C) conforming to IEC 60695-2-121760 °F (960 °C) parts supporting live components conforming to IEC 60695-2-12
- Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2
- Non-dissipating shock wave: 1 kV serial mode conforming to IEC 60947-6-22 kV common mode conforming to IEC 60947-6-2
- Resistance to radiated fields: 9.14 V/yd (10 V/m) 3 conforming to IEC 61000-4-3
- Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
- Immunity to radio electric fields: 10 V conforming to IEC 61000-4-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LUCA05FU . Santa Clara Systems carries 10,632 items from Telemecanique.
- Standard Control Unit Luca - Class 10 - 1.25...5 A - 110...220 V Dc/ac
Alternates
Common Typos
- 1UCA05FU
- 1UCA0SFU
- 1UCAO5FU
- 1UCAOSFU
- IUCA05FU
- IUCA0SFU
- IUCAO5FU
- IUCAOSFU
- LUCA0SFU
- LUCAO5FU
- LUCAOSFU
Appended Numbers
- LUCA05FU-A
- LUCA05FU-B
- LUCA05FU-C
- LUCA05FU-D
- LUCA05FU-E
- LUCA05FU-F
- LUCA05FU-G
- LUCA05FU-H
- LUCA05FU-I
- LUCA05FU-J
- LUCA05FU-K
- LUCA05FU-L
- LUCA05FU-M
- LUCA05FU-N
- LUCA05FU-O
- LUCA05FU-P
- LUCA05FU-Q
- LUCA05FU-R
- LUCA05FU-S
- LUCA05FU-T
- LUCA05FU-U
- LUCA05FU-V
- LUCA05FU-W
- LUCA05FU-X
- LUCA05FU-Y
- LUCA05FU-Z
Customers Are Also Buying
-
800F-N3R
Allen Bradley
-
XS6 18B1NAM12
Telemecanique
-
140M-C2E-C10
Allen Bradley
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier
