281D-F12Z-10B-CR
Out of Stock
Product Summary:
- Control Voltage: 24V DC
- Enclosure Type: NEMA Type 4 Watertight Enclosure - IP 67
- Connection type: Quick disconnects
- Motor Current: - No Value
- Utilization category: Power circuit: AC-3 per IEC
Let Us Find It
Current response time:
8 Minutes 25 Seconds
- Description: Reversing Starter
- Control Voltage: 24V DC
- Enclosure Type: NEMA Type 4 Watertight Enclosure - IP 67
- Connection type: Quick disconnects
- Motor Current: - No Value
- Utilization category: Power circuit: AC-3 per IEC
- Communications: DeviceNet
- Line/Motor Connections: Conduit Entrance with Motor Cable Suppliedwith 3 m (9.8 ft) unshielded male cordset
- Bulletin Number: 281 Reversing Starter
- Current Range: Current Range 0.5...2.5 A
- Baud rates: 500 kBps
- Overload selection current range: 0.5 A
- Communication: DeviceNet
- Short circuit protection: 10 A rated device
- DeviceNet input current surge: 15 A for 250 μs
- DeviceNet input current: 364 mA @ 11V DC - 4.0 W
- Total with maximum sensor inputs (4): 367 mA @ 24V DC - 8.8 W
- Overvoltage category: Control circuit: III per IEC
- Rated operational current: Power circuit: 2.5 A maximum
- DeviceNet supply voltage rating: 24V DC nominal
- Control (pick up): Power requirements: 0.71 A without HOA
- Control (hold in): Power requirements: 0.063 A without HOA
- Rated input operation voltage: 24V DC
- Input OFF-state current: <1.5 mA
- Input OFF-state voltage: 0...5V DC
- Input ON-state voltage: 10...26V DC
- Distance, max: 500 m (1630 ft) @ 125 kbps
- Operating frequency: Power circuit: 50/60 Hz
- Input ON-state current: 7.2 mA @ 24V DC
- Option 1: Status only keypad
- Number of contacts: Output rating- sourced from control circuit: 2
- Voltage status only: 11...25V DC from DeviceNet
- Outputs current (2) 1 A max. each: External devices powered by control voltage: 2 A without HOA
- Trip rating: 120% of full load current (FLC) setting
- Total control power (pick up) with max outputs: External devices powered by control voltage: 73 W with HOA
- Total control power (hold in) with max outputs: External devices powered by control voltage: 58 W with HOA
- Input compatibility: IEC 1133 Type 1+ per IEC
- Application in industrial area permitted (SCPD list): Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
- Rated output operation voltage: Sourced from control circuit: 30V DC
- Insulation voltage: Power circuit: rated 600V
- Dielectric withstand: Power circuit: 2500V AC per IEC
- Type of contacts: Output rating- sourced from control circuit: normally open (NO)
- Current available: 50 mA maximum per input, 200 mA total
- Conventional thermal current (Ith): Output rating- sourced from control circuit: total of both outputs ≤2 A
- Circuit breaker operational current rating, max: 60 A @ 480V (with gland type: CR or DR)
- RMS symmetrical amperes: 65 kA @ 480Y/277V (with gland type: RR)
- Rated operation voltage: Power circuit: 200...575V
- 3-phase power/motor cable connection: Conduit entrance with motor cable
- Input filter - software selectable: Settable from 0...64 ms in 1 ms increments (ON to OFF)
- Kind of current: Output ratings (sourced from control circuit): AC/DC (not to be used as an AC/DC power supply)
- Fuse operational current rating, max: Time delay: 20 A @ 480Y/277V (with gland type: RR)
- Total control power (pick up): Power requirements: 21 W with HOA
- Total control power (hold in): Power requirements: 5.6 W with HOA
- Trip class: Class 10, 15, 20
- Operational power rating: Reversing starters – IP67/Type 4/12: 1.5 Hp @ 575V AC, 60 Hz
- Number of digital inputs: 4
- Number of digital outputs: 2
- Supporting protocol for DeviceNet: Yes
- Application in industrial area permitted: Yes
- Mains frequency: 50/60 Hz
- Short circuit protection device performance (SCPD) type: Type 1
- Short circuit rating: 30 kA
- Disconnect: Motor disconnect
- External devices powered by DeviceNet: 50 mA - total 200 mA
- Electrical life cycle: Output ratings (sourced from control circuit): 100000 operations (1.8K operations/hr)
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on 281D-F12Z-10B-CR . Santa Clara Systems carries 55,747 items from Allen Bradley.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
Common Typos
- 281D-F122-108-CR
- 281D-F122-10B-CR
- 281D-F122-1O8-CR
- 281D-F122-1OB-CR
- 281D-F122-I08-CR
- 281D-F122-I0B-CR
- 281D-F122-IO8-CR
- 281D-F122-IOB-CR
- 281D-F122-L08-CR
- 281D-F122-L0B-CR
- 281D-F122-LO8-CR
- 281D-F122-LOB-CR
- 281D-F12Z-108-CR
- 281D-F12Z-1O8-CR
- 281D-F12Z-1OB-CR
- 281D-F12Z-I08-CR
- 281D-F12Z-I0B-CR
- 281D-F12Z-IO8-CR
- 281D-F12Z-IOB-CR
- 281D-F12Z-L08-CR
- 281D-F12Z-L0B-CR
- 281D-F12Z-LO8-CR
- 281D-F12Z-LOB-CR
- 281D-F1ZZ-108-CR
- 281D-F1ZZ-10B-CR
- 281D-F1ZZ-1OB-CR
Appended Numbers
- 281D-F12Z-10B-CR-A
- 281D-F12Z-10B-CR-B
- 281D-F12Z-10B-CR-C
- 281D-F12Z-10B-CR-D
- 281D-F12Z-10B-CR-E
- 281D-F12Z-10B-CR-F
- 281D-F12Z-10B-CR-G
- 281D-F12Z-10B-CR-H
- 281D-F12Z-10B-CR-I
- 281D-F12Z-10B-CR-J
- 281D-F12Z-10B-CR-K
- 281D-F12Z-10B-CR-L
- 281D-F12Z-10B-CR-M
- 281D-F12Z-10B-CR-N
- 281D-F12Z-10B-CR-O
- 281D-F12Z-10B-CR-P
- 281D-F12Z-10B-CR-Q
- 281D-F12Z-10B-CR-R
- 281D-F12Z-10B-CR-S
- 281D-F12Z-10B-CR-T
- 281D-F12Z-10B-CR-U
- 281D-F12Z-10B-CR-V
- 281D-F12Z-10B-CR-W
- 281D-F12Z-10B-CR-X
- 281D-F12Z-10B-CR-Y
- 281D-F12Z-10B-CR-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier