  • Description: Flow Meter | SMR11GGXFRKG/US-100
  • Electrical Design: Pnp/Npn
  • Output Function: Normally Open / Closed; (Configurable)
  • Material: Stainless Steel (1.4404 / 316L); Pbt-Gf20; Pc; Fkm; Tpe
  • Resolution: 0.1 L/Min 0.005 M/H
  • Installation: Connection To Pipe By Means Of An Adapter
  • Media: Conductive Liquids; Water; Water-Based Media
  • Medium Temperature [C]: -10...70
  • Pressure Rating [Bar]: 16
  • Mawp (For Applications According To Crn) [Bar]: 11.2
  • Operating Voltage [V]: 18...30 Dc; (According To En 50178 Selv/Pelv)
  • Current Consumption [Ma]: 95; (24 V)
  • Protection Class: Iii
  • Reverse Polarity Protection: Yes
  • Power-On Delay Time [S]: 5
  • Number Of Inputs And Outputs: Number Of Digital Outputs: 2; Number Of Analog Outputs: 1
  • Inputs: Counter Reset
  • Total Number Of Outputs: 2
  • Output Signal: Switching Signal; Analog Signal; Pulse Signal; Io-Link; (Configurable)
  • Number Of Digital Outputs: 2
  • Max. Voltage Drop Switching Output Dc [V]: 2
  • Permanent Current Rating Of Switching Output Dc [Ma]: 200
  • Number Of Analog Outputs: 1
  • Analog Current Output [Ma]: 4...20; (Scalable)
  • Max. Load [?]: 500
  • Analog Voltage Output [V]: 0...10; (Scalable)
  • Min. Load Resistance [?]: 2000
  • Pulse Output: Flow Rate Meter
  • Short-Circuit Protection: Yes
  • Type Of Short-Circuit Protection: Yes (Non-Latching)
  • Overload Protection: Yes
  • Measuring Range: 0.2...100 L/Min 0.01...6 M/H
  • Display Range: -120...120 L/Min -7.2...7.2 M/H
  • Set Point Sp: 0.7...100 L/Min 0.04...6 M/H
  • Reset Point Rp: 0.2...99.5 L/Min 0.01...5.97 M/H
  • Analog Start Point Asp: 0...80 L/Min 0...4.8 M/H
  • Analog End Point Aep: 20...100 L/Min 1.2...6 M/H
  • In Steps Of: 0.1 L/Min 0.005 M/H
  • Pulse Value: 0.00001...100 000 M
  • Pulse Length [S]: 0,0025...2
  • Measuring Range [C]: -20...80
  • Resolution [C]: 0.2
  • Set Point Sp [C]: -19.2...80
  • Reset Point Rp [C]: -19.6...79.6
  • Analog Start Point [C]: -20...60
  • Analog End Point [C]: 0...80
  • In Steps Of [C]: 0.2
  • Accuracy (In The Measuring Range): (0,8 % Mw + 0,5 % Mew)
  • Repeatability: 0,2% Mew
  • Accuracy [K]: 2,5 (Q > 5 L/Min)
  • Response Time [S]: 0.15; (Dap = 0)
  • Delay Time Programmable Ds, Dr [S]: 0...50
  • Damping For The Switching Output Dap [S]: 0...5
  • Dynamic Response T05 / T09 [S]: T09 = 20 (Q > 5 L/Min)
  • Parameter Setting Options: Flow Monitoring; Quantity Meter; Preset Counter; Temperature Monitoring; Hysteresis / Window; Normally Open / Closed; Switching Logic; Current/Voltage/Pulse Output; Start-Up Delay; Display Can Be Deactivated; Display Unit
  • Communication Interface: Io-Link
  • Transmission Type: Com2 (38,4 Kbaud)
  • Io-Link Revision: 1.1
  • Sdci Standard: Iec 61131-9
  • Io-Link Device Id: 575 / 00 02 3F
  • Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
  • Sio Mode: Yes
  • Required Master Port Class: A
  • Process Data Analogue: 3
  • Process Data Binary: 2
  • Min. Process Cycle Time [Ms]: 5
  • Ambient Temperature [C]: -10...60
  • Storage Temperature [C]: -25...80
  • Protection: Ip 67
  • Emc: Din En 60947-5-9
  • Shock Resistance: Din Iec 68-2-27 20 G (11 Ms)
  • Vibration Resistance: Din Iec 68-2-6 5 G (10...2000 Hz)
  • Pressure Equipment Directive: Sound Engineering Practice; Can Be Used For Group 2 Fluids; Group 1 Fluids On Request
  • Materials (Wetted Parts): Stainless Steel (1.4404 / 316L); Peek; Fkm
  • Process Connection: Threaded Connection G 1 Dn25 Flat Seal
  • Display: Display Unit 6 X Led, Green (L/Min, M/H, L, M, 10, C) Switching Status 2 X Led, Yellow Measured Values Alphanumeric Display, 4-Digit Programming Alphanumeric Display, 4-Digit
  • Connection: Connector: 1 X M12; Contacts: Gold-Plated
  • Pressure Loss: Dp Pressure Loss Q Volumetric Flow Quantity
  • Alternate Manufacturer Name: IFM
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on SM8000 . Santa Clara Systems carries 2,203 items from Efector.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.

Alternates

  • SMR11GGXFRKG/US-100

Common Typos

  • 5M8000
  • 5M800O
  • 5M80O0
  • 5M80OO
  • 5M8O00
  • 5M8O0O
  • 5M8OO0
  • 5M8OOO
  • 5MB000
  • 5MB00O
  • 5MB0O0
  • SM800O
  • SM80O0
  • SM80OO
  • SM8O00
  • SM8O0O
  • SM8OO0
  • SM8OOO
  • SMB000
  • SMB00O
  • SMB0O0
  • SMB0OO
  • SMBO00
  • SMBO0O
  • SMBOO0
  • SMBOOO

Appended Numbers

  • SM8000-A
  • SM8000-B
  • SM8000-C
  • SM8000-D
  • SM8000-E
  • SM8000-F
  • SM8000-G
  • SM8000-H
  • SM8000-I
  • SM8000-J
  • SM8000-K
  • SM8000-L
  • SM8000-M
  • SM8000-N
  • SM8000-O
  • SM8000-P
  • SM8000-Q
  • SM8000-R
  • SM8000-S
  • SM8000-T
  • SM8000-U
  • SM8000-V
  • SM8000-W
  • SM8000-X
  • SM8000-Y
  • SM8000-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo