• ABB 2CCS894001R0065 S804N-B6 High Performance Circuit Breaker Product Image
  • Abb 2CCS894001R0065 Barcode

2CCS894001R0065

Product Summary:

  • Extended Product Type: S804N-B6
  • Product ID: 2CCS894001R0065
  • EAN: 7612271408459
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85362020
Let Us Find It
           or           
  • Description: S804N-B6 High Performance Circuit Breaker
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu): (240 / 415 V AC) 36 kA (254 / 440 V AC) 20 kA (400 / 690 V AC) 4.5 kA (125 V DC) 20 kA
  • Rated Service Short-Circuit Breaking Capacity (Ics): (240 / 415 V AC) 30 kA (254 / 440 V AC) 15 kA (400 / 690 V AC) 3 kA (125 V DC) 20 kA
  • Overvoltage Category: IV
  • Pollution Degree: 3
  • Rated Impulse Withstand Voltage (Uimp): 8 kV
  • Housing Material: Insulation group I, RAL 7035
  • Contact Position Indication: ON / OFF / TRIP
  • Degree of Protection: acc. to IEC 60529 IP20
  • Remarks: Connection from top and bottom
    Connecting with CU only
    IP40 in enclosure with cover
    Cage terminal with captive screw
  • Electrical Endurance: 10000 cycle
  • Mechanical Endurance: 10000 cycle
  • Terminal Type: Screw Terminals
  • Connecting Capacity: Stranded 1 ... 50 mm² Flexible 1 70 mm²
  • Tightening Torque: 3.5 N·m 31 in·lb
  • Recommended Screw Driver: Pozidriv 2
  • Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Mounting Position: Any
  • Standards: IEC/EN 60947-2 IEC/EN 60898-1
  • Instructions and Manuals: 2CCC413016M0004
  • Data Sheet, Technical Information: 2CCC413003C0203
  • Declaration of Conformity - CE: 2CCC413016D060
  • RoHS Information: 2CCC413008D0204
  • ETIM 4: EC000042 - Miniature circuit breaker (MCB)
  • ETIM 5: EC000042 - Miniature circuit breaker (MCB)
  • ETIM 6: EC000042 - Miniature circuit breaker (MCB)
  • Object Classification Code: F
  • Extended Product Type: S804N-B6
  • Product ID: 2CCS894001R0065
  • EAN: 7612271408459
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85362020
  • EAN: 7612271408459
  • Product Net Depth: 82.5 mm
  • Product Net Height: 95 mm
  • Product Net Weight: 0.98 kg
  • Product Net Width: 106 mm
  • Package Level 1 Width: 105 mm
  • Package Level 1 Length: 111 mm
  • Package Level 1 Height: 99 mm
  • Package Level 1 Gross Weight: 1.01 kg
  • Package Level 1 EAN: 7612271408459
  • Package Level 1 Units: 1 piece
  • Ambient Air Temperature: Operation -25 ... +60 °C Storage -40 ... +70 °C
  • Resistance to Shock acc. to IEC 60068-2-27: 5 g 30 ms
  • Resistance to Vibrations acc. to IEC 60068-2-6: 2 - 13.2 Hz / 1mm
    13.2 - 100Hz / 0.7g
    with load 100% x Ie
  • Environmental Conditions: Damp Heat Cyclic acc. to IEC 60068-2-30 12+12 cycle Damp Heat Cyclic acc. to IEC 60068-2-30 55°C @ 90-96% Damp Heat Cyclic acc. to IEC 60068-2-30 25°C @ 90-100% Dry Heat Test B acc. to IEC 60068-2-2 16 hour @ 55 °C Dry Heat Test B acc. to IEC 60068-2-2 2 hour @ 70 °C
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Number of Poles: 4
  • Tripping Characteristic: B
  • Rated Current (In): 6 A
  • Rated Operational Voltage: 400/690 V AC 375 V DC
  • Power Loss: at Rated Operating Conditions per Pole 1.8 W
  • Rated Insulation Voltage (Ui): 690 V AC
  • Rated Frequency (f): 50 / 60 Hz
Santa Clara Systems specialises in hard-to-find parts. Choose from our overstock inventory and save on 2CCS894001R0065 . Santa Clara Systems carries 35,866 items from ABB.
  • Therefore It Can Be Used Worldwide. The Extensive Range Of Accessory Makes The Use Of S804N-B6 More Comfortable. Due To The Fast Arc Extinction Of S804N-B6 Your Application Will Be Secured.
  • The S804N-B6 Is A 4-Pole High Performance Circuit Breaker With B-Characteristic
  • With Cage Terminal And A Rated Current Of 6 A. It Is A Current Limiting Device With A Maximum Breaking Capacity Of 36Ka At 240/415V. It Can Be Used For Voltages Up To 400/690V And In Dc As Well. It Has Two Different Tripping Mechanisms
  • The Thermal Tripping Mechanism For Overload Protection And The Electromechanic Tripping Mechanism For Short Circuit Protection. The S804N-B6 Complies With Iec/En 60947-2 And Allows The Use For Industrial Applications. It Has Numerous Of Approvals
  • Alternates

    • S804N-B6
    • S804N B6
    • S804NB6

    Common Types

    • 2CCS894001R006S
    • 2CCS894001R00G5
    • 2CCS894001R00GS
    • 2CCS894001R0O65
    • 2CCS894001R0O6S
    • 2CCS894001R0OG5
    • 2CCS894001R0OGS
    • 2CCS894001RO065
    • 2CCS894001RO06S
    • 2CCS894001RO0G5
    • 2CCS894001RO0GS
    • 2CCS894001ROO65
    • 2CCS894001ROO6S
    • 2CCS894001ROOG5
    • 2CCS894001ROOGS
    • 2CCS89400IR0065
    • 2CCS89400IR006S
    • 2CCS89400IR00G5
    • 2CCS89400IR00GS
    • 2CCS89400IR0O65
    • 2CCS89400IR0O6S
    • 2CCS89400IR0OG5
    • 2CCS89400IR0OGS
    • 2CCS89400IRO065
    • 2CCS89400IRO06S

    Appended Numbers

    • 2CCS894001R0065-A
    • 2CCS894001R0065-B
    • 2CCS894001R0065-C
    • 2CCS894001R0065-D
    • 2CCS894001R0065-E
    • 2CCS894001R0065-F
    • 2CCS894001R0065-G
    • 2CCS894001R0065-H
    • 2CCS894001R0065-I
    • 2CCS894001R0065-J
    • 2CCS894001R0065-K
    • 2CCS894001R0065-L
    • 2CCS894001R0065-M
    • 2CCS894001R0065-N
    • 2CCS894001R0065-O
    • 2CCS894001R0065-P
    • 2CCS894001R0065-Q
    • 2CCS894001R0065-R
    • 2CCS894001R0065-S
    • 2CCS894001R0065-T
    • 2CCS894001R0065-U
    • 2CCS894001R0065-V
    • 2CCS894001R0065-W
    • 2CCS894001R0065-X
    • 2CCS894001R0065-Y
    • 2CCS894001R0065-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier Domestic and International
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo