- Description: Contactor
- Product weight: 7.56 lb(US) (3.43 kg)
- IP degree of protection: IP2x front face with shrouds (ordered separately) conforming to IEC 60529IP2x front face with shrouds (ordered separately) conforming to VDE 0106
- Standards: JIS C8201-4-1EN 60947-4-1EN 60947-1IEC 60947-4-1IEC 60947-1
- Device short name: LC1F
- Width: 6.43 in (163.3 mm)
- Height: 6.38 in (162 mm)
- Depth: 6.73 in (171 mm)
- Protective treatment: TH
- [Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C
- [Uimp] rated impulse withstand voltage: 8 kV
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Mechanical durability: 10 Mcycles
- Tightening torque: Control circuit: 10.62 lbf.in (1.2 N.m)Power circuit: 88.5 lbf.in (10 N.m)
- Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable endPower circuit: connector 1 cable(s) 0.15 in² (95 mm²)Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endPower circuit: lugs-ring terminals 1 cable(s) 0.15 in² (95 mm²)Power circuit : bolted connectionPower circuit : bar 2 x (20 x 3 mm)
- Range: TeSys
- Mounting support: Plate
- [Ith] conventional free air thermal current: 200 A at <= 104 °F (40 °C)
- System Voltage: <= 1000 V AC 50/60 Hz<= 460 V DC
- Operating rate: 2400 cyc/h at <= 131 °F (55 °C)
- Product name: TeSys F
- [Uc] control circuit voltage: 120 V AC 60 Hz
- motor power kW: 55 kW at 380...400 V AC 50/60 Hz AC-359 kW at 415 V AC 50/60 Hz AC-359 kW at 440 V AC 50/60 Hz AC-375 kW at 500 V AC 50/60 Hz AC-380 kW at 660...690 V AC 50/60 Hz AC-330 kW at 220...230 V AC 50/60 Hz AC-365 kW at 1000 V AC 50/60 Hz AC-318.5 kW at 400 V AC 50/60 Hz AC-4
- [Ie] rated operational current: 200 A (<= 104 °F (40 °C)) at <= 440 V AC AC-1115 A (<= 131 °F (55 °C)) at <= 440 V AC AC-3
- Utilization category: AC-4AC-1AC-3
- Control circuit voltage limits: 0.35...0.55 Uc at 131 °F (55 °C) drop-out 50/60 Hz0.85...1.1 Uc at 131 °F (55 °C) operational 50/60 Hz
- Poles description: 3P
- Overvoltage category: III
- Operating time: 23...35 ms closing5...15 ms opening
- Associated fuse rating: 125 A aM at <= 440 V200 A gG at <= 440 V
- Product or component type: Contactor
- Ambient air temperature for operation: 23...131 °F (-5...55 °C)
- Rated breaking capacity: 920 A conforming to IEC 60947-4-1
- Ambient air temperature for storage: -76...176 °F (-60...80 °C)
- Contactor application: Resistive loadMotor control
- [Icw] rated short-time withstand current: 1100 A <= 104 °F (40 °C) 10 s640 A <= 104 °F (40 °C) 30 s520 A <= 104 °F (40 °C) 1 min400 A <= 104 °F (40 °C) 3 min320 A <= 104 °F (40 °C) 10 min
- Permissible ambient air temperature around the device: -40...158 °F (-40...70 °C)
- Average impedance: 0.37 mOhm at 50 Hz - Ith 200 A
- Mechanical robustness: Vibrations contactor closed 6 Gn, 5...300 HzShocks contactor open 9 Gn for 11 msVibrations contactor open 2 Gn, 5...300 HzShocks contactor closed 15 Gn for 11 ms
- Pole contact composition: 3 NO
- Power dissipation per pole: 15 W AC-15 W AC-3
- Product certifications: RINADNVABSBVRMRoSULLROS (Lloyds register of shipping)CCCCB
- inrush power in VA: 660 VA at 68 °F (20 °C) (cos ? 0.3) 60 Hz
- hold-in power consumption in VA: 55 VA at 68 °F (20 °C) (cos ? 0.3) 60 Hz
- Heat dissipation: 12...16 W
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1F115G6 . Santa Clara Systems carries 10,632 items from Telemecanique.
- Tesys F Contactor - 3p (3 No) - Ac-3 - <= 440 V 115 A - Coil 120 V Ac
Alternates
Common Typos
- LC1F11566
- LC1F1156G
- LC1F115GG
- LC1F11S66
- LC1F11S6G
- LC1F11SG6
- LC1F11SGG
- LC1F1I566
- LC1F1I56G
- LC1F1I5G6
- LC1F1I5GG
- LC1F1IS66
- LC1F1IS6G
- LC1F1ISG6
- LC1F1ISGG
- LC1F1L566
- LC1F1L56G
- LC1F1L5G6
- LC1F1L5GG
- LC1F1LS66
- LC1F1LS6G
- LC1F1LSG6
- LC1F1LSGG
- LC1FI1566
- LC1FI15G6
- LC1FI15GG
Appended Numbers
- LC1F115G6-A
- LC1F115G6-B
- LC1F115G6-C
- LC1F115G6-D
- LC1F115G6-E
- LC1F115G6-F
- LC1F115G6-G
- LC1F115G6-H
- LC1F115G6-I
- LC1F115G6-J
- LC1F115G6-K
- LC1F115G6-L
- LC1F115G6-M
- LC1F115G6-N
- LC1F115G6-O
- LC1F115G6-P
- LC1F115G6-Q
- LC1F115G6-R
- LC1F115G6-S
- LC1F115G6-T
- LC1F115G6-U
- LC1F115G6-V
- LC1F115G6-W
- LC1F115G6-X
- LC1F115G6-Y
- LC1F115G6-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier