  • Description: Contactor
  • Product weight: 7.56 lb(US) (3.43 kg)
  • IP degree of protection: IP2x front face with shrouds (ordered separately) conforming to IEC 60529IP2x front face with shrouds (ordered separately) conforming to VDE 0106
  • Standards: JIS C8201-4-1EN 60947-4-1EN 60947-1IEC 60947-4-1IEC 60947-1
  • Device short name: LC1F
  • Width: 6.43 in (163.3 mm)
  • Height: 6.38 in (162 mm)
  • Depth: 6.73 in (171 mm)
  • Protective treatment: TH
  • [Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C
  • [Uimp] rated impulse withstand voltage: 8 kV
  • Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
  • Mechanical durability: 10 Mcycles
  • Tightening torque: Control circuit: 10.62 lbf.in (1.2 N.m)Power circuit: 88.5 lbf.in (10 N.m)
  • Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable endPower circuit: connector 1 cable(s) 0.15 in² (95 mm²)Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endPower circuit: lugs-ring terminals 1 cable(s) 0.15 in² (95 mm²)Power circuit : bolted connectionPower circuit : bar 2 x (20 x 3 mm)
  • Range: TeSys
  • Mounting support: Plate
  • [Ith] conventional free air thermal current: 200 A at <= 104 °F (40 °C)
  • System Voltage: <= 1000 V AC 50/60 Hz<= 460 V DC
  • Operating rate: 2400 cyc/h at <= 131 °F (55 °C)
  • Product name: TeSys F
  • [Uc] control circuit voltage: 120 V AC 60 Hz
  • motor power kW: 55 kW at 380...400 V AC 50/60 Hz AC-359 kW at 415 V AC 50/60 Hz AC-359 kW at 440 V AC 50/60 Hz AC-375 kW at 500 V AC 50/60 Hz AC-380 kW at 660...690 V AC 50/60 Hz AC-330 kW at 220...230 V AC 50/60 Hz AC-365 kW at 1000 V AC 50/60 Hz AC-318.5 kW at 400 V AC 50/60 Hz AC-4
  • [Ie] rated operational current: 200 A (<= 104 °F (40 °C)) at <= 440 V AC AC-1115 A (<= 131 °F (55 °C)) at <= 440 V AC AC-3
  • Utilization category: AC-4AC-1AC-3
  • Control circuit voltage limits: 0.35...0.55 Uc at 131 °F (55 °C) drop-out 50/60 Hz0.85...1.1 Uc at 131 °F (55 °C) operational 50/60 Hz
  • Poles description: 3P
  • Overvoltage category: III
  • Operating time: 23...35 ms closing5...15 ms opening
  • Associated fuse rating: 125 A aM at <= 440 V200 A gG at <= 440 V
  • Product or component type: Contactor
  • Ambient air temperature for operation: 23...131 °F (-5...55 °C)
  • Rated breaking capacity: 920 A conforming to IEC 60947-4-1
  • Ambient air temperature for storage: -76...176 °F (-60...80 °C)
  • Contactor application: Resistive loadMotor control
  • [Icw] rated short-time withstand current: 1100 A <= 104 °F (40 °C) 10 s640 A <= 104 °F (40 °C) 30 s520 A <= 104 °F (40 °C) 1 min400 A <= 104 °F (40 °C) 3 min320 A <= 104 °F (40 °C) 10 min
  • Permissible ambient air temperature around the device: -40...158 °F (-40...70 °C)
  • Average impedance: 0.37 mOhm at 50 Hz - Ith 200 A
  • Mechanical robustness: Vibrations contactor closed 6 Gn, 5...300 HzShocks contactor open 9 Gn for 11 msVibrations contactor open 2 Gn, 5...300 HzShocks contactor closed 15 Gn for 11 ms
  • Pole contact composition: 3 NO
  • Power dissipation per pole: 15 W AC-15 W AC-3
  • Product certifications: RINADNVABSBVRMRoSULLROS (Lloyds register of shipping)CCCCB
  • inrush power in VA: 660 VA at 68 °F (20 °C) (cos ? 0.3) 60 Hz
  • hold-in power consumption in VA: 55 VA at 68 °F (20 °C) (cos ? 0.3) 60 Hz
  • Heat dissipation: 12...16 W
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1F115G6 . Santa Clara Systems carries 10,632 items from Telemecanique.
  • Tesys F Contactor - 3p (3 No) - Ac-3 - <= 440 V 115 A - Coil 120 V Ac

Alternates

    Common Typos

    • LC1F11566
    • LC1F1156G
    • LC1F115GG
    • LC1F11S66
    • LC1F11S6G
    • LC1F11SG6
    • LC1F11SGG
    • LC1F1I566
    • LC1F1I56G
    • LC1F1I5G6
    • LC1F1I5GG
    • LC1F1IS66
    • LC1F1IS6G
    • LC1F1ISG6
    • LC1F1ISGG
    • LC1F1L566
    • LC1F1L56G
    • LC1F1L5G6
    • LC1F1L5GG
    • LC1F1LS66
    • LC1F1LS6G
    • LC1F1LSG6
    • LC1F1LSGG
    • LC1FI1566
    • LC1FI15G6
    • LC1FI15GG

    Appended Numbers

    • LC1F115G6-A
    • LC1F115G6-B
    • LC1F115G6-C
    • LC1F115G6-D
    • LC1F115G6-E
    • LC1F115G6-F
    • LC1F115G6-G
    • LC1F115G6-H
    • LC1F115G6-I
    • LC1F115G6-J
    • LC1F115G6-K
    • LC1F115G6-L
    • LC1F115G6-M
    • LC1F115G6-N
    • LC1F115G6-O
    • LC1F115G6-P
    • LC1F115G6-Q
    • LC1F115G6-R
    • LC1F115G6-S
    • LC1F115G6-T
    • LC1F115G6-U
    • LC1F115G6-V
    • LC1F115G6-W
    • LC1F115G6-X
    • LC1F115G6-Y
    • LC1F115G6-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo