A9-30-10-42
Resumen del Producto:
- Extended Product Type: A9-30-10 230-240V 50Hz / 277V 60Hz
- Product ID: 1SBL141001R4210
- EAN: 3471522031426
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Descripción: Contactor
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ? ? 55 °C) °C
- Rated Control Circuit Voltage (Uc): 50 Hz 230 240 V 60 Hz 277 V
- Coil Consumption: Average Holding Value 50 Hz 8 V·A Average Holding Value 50 Hz 2 W Average Holding Value 60 Hz 8 V·A Average Holding Value 60 Hz 2 W Average Pull-in Value 50 Hz 70 V·A Average Pull-in Value 60 Hz 80 V·A
- Operate Time: Between Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
- Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
- Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
- Connecting terminals (delivered in open position) Main poles: M 3.5 (+,-) pozidriv 2 screws with cable clamp
- Terminal Type: Screw Terminals
- Number of Main Contacts NO: 3
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Operating Altitude Permissible: 3000 m
- Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
- Instructions and Manuals: FPTC407721P0001
- BV Certificate: BV_2634H07559D0
- CB Certificate: CB_FR_602227A
- CCC Certificate: CCC_2013010304615753 CCC_2004010309130463
- CSA Certificate: CSA_1041746
- cUL Certificate: UL_20160205-E312527-10-2
- Data Sheet, Technical Information: 1SBC100122C0202_Ch02
- Declaration of Conformity - CE: 1SBD250801U1000
- DNV Certificate: DNV-GL_TAE00000TX
- EAC Certificate: EAC_RU C-FR ME77 B01010
- GL Certificate: DNV-GL_TAE00000TX
- GOST Certificate: GOST_POCCFRME77B07175
- LOVAG Certificate: LOVAG_FR97037
- LR Certificate: LRS_9830011E4
- RINA Certificate: RINA_ELE128713XG001
- RMRS Certificate: RMRS_0507015250
- RoHS Information: 1SBD350050R1000
- UL Certificate: UL_071301E39231
- UL Listing Card: UL_E312527
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
- Extended Product Type: A9-30-10 230-240V 50Hz / 277V 60Hz
- Product ID: 1SBL141001R4210
- EAN: 3471522031426
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- EAN: 3471522031426
- Product Net Depth: 74 mm
- Product Net Height: 74 mm
- Product Net Weight: 0.340 kg
- Product Net Width: 44 mm
- Package Level 1 Width: 78 mm
- Package Level 1 Length: 76 mm
- Package Level 1 Height: 47 mm
- Package Level 1 Gross Weight: 0.34 kg
- Package Level 1 EAN: 3471522031426
- Package Level 2 Units: 63 piece
- Package Level 3 Units: 1220 piece
- Package Level 1 Units: 1 piece
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 0
- Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
- Rated Operational Voltage: Main Circuit 690 V
- Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 26 A acc. to IEC 60947-5-1, q = 40 °C 16 A
- Rated Operational Current AC-1 (Ie): (690 V) 40 °C 25 A (690 V) 55 °C 22 A (690 V) 70 °C 18 A
- Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 °C 9 A (380 / 400 V) 55 °C 9 A (415 V) 55 °C 9 A (440 V) 55 °C 9 A (500 V) 55 °C 9 A (690 V) 55 °C 7 A
- Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 2.2 kW (380 / 400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 25 A
- Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 60 A for 0.1 s 140 A for 1 s 100 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
- Rated Operational Current DC-13 (Ie): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
- Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp): 8 kV
- Mechanical Durability: 10 million
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
Santa Clara Systems se especializa en piezas difíciles de encontrar. Elija de nuestro inventario de exceso y ahorre en A9-30-10-42 . Santa Clara Systems tiene 36,195 artículos de ABB.
Estamos en el proceso de agregar los datos y el material descargable para este artículo. Por favor, busque artículos similares para obtener más información en relación con este producto.
Alternativas
- A9-30-10-42
Errores Tipográficos Comunes
- A9-30-10-4Z
- A9-30-1O-42
- A9-30-1O-4Z
- A9-30-I0-42
- A9-30-I0-4Z
- A9-30-IO-42
- A9-30-IO-4Z
- A9-30-L0-42
- A9-30-L0-4Z
- A9-30-LO-42
- A9-30-LO-4Z
- A9-3O-10-42
- A9-3O-10-4Z
- A9-3O-1O-42
- A9-3O-1O-4Z
- A9-3O-I0-42
- A9-3O-I0-4Z
- A9-3O-IO-42
- A9-3O-IO-4Z
- A9-3O-L0-42
- A9-3O-L0-4Z
- A9-3O-LO-42
- A9-3O-LO-4Z
Números Adjuntos
- A9-30-10-42-A
- A9-30-10-42-B
- A9-30-10-42-C
- A9-30-10-42-D
- A9-30-10-42-E
- A9-30-10-42-F
- A9-30-10-42-G
- A9-30-10-42-H
- A9-30-10-42-I
- A9-30-10-42-J
- A9-30-10-42-K
- A9-30-10-42-L
- A9-30-10-42-M
- A9-30-10-42-N
- A9-30-10-42-O
- A9-30-10-42-P
- A9-30-10-42-Q
- A9-30-10-42-R
- A9-30-10-42-S
- A9-30-10-42-T
- A9-30-10-42-U
- A9-30-10-42-V
- A9-30-10-42-W
- A9-30-10-42-X
- A9-30-10-42-Y
- A9-30-10-42-Z
Clientes También Están Comprando
-
IC697 ACC 701 (BATTERY)
General Electric
-
3RV1 021-1JA10
Siemens
-
800F-MX20
Allen Bradley
-
LUB 32
Telemecanique
Entrega que cumple con sus necesidades

- ✓ Horas Tardes de Envió de la Costa Oeste (5PM Hora del Pacifico)
- ✓ Especialistas en Entrega Directa y Entrega Ciega
- ✓ Empacado por Expertos Estática Reducida
- ✓ Servicio el Mismo Día
- ✓ Mensajero Interno Nacional e Internacional