CPX-E-4AO-U-I
Product Summary:
- Ambient temperature: -5 °C ... 50 °C
- Dimensions W x L x H: 18.9 mm x 76.6 mm x 124.3 mm
- Width dimension: 18.9 mm
- Type of mounting: With H-rail
- Mounting position: Vertical - Horizontal
- Description: Analogue Output Module
- Ambient temperature: -5 °C ... 50 °C
- Dimensions W x L x H: 18.9 mm x 76.6 mm x 124.3 mm
- Width dimension: 18.9 mm
- Type of mounting: With H-rail
- Mounting position: Vertical - Horizontal
- Note on ambient temperature: -5 - 60 °C for vertical installation
- Storage temperature: -20 °C ... 70 °C
- Relative air humidity: 95 % - Non-condensing
- Degree of protection: IP20
- Corrosion resistance class (CRC): 0 - No corrosion stress
- Vibration resistance: Transport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6
- Shock resistance: Shock test with severity level 1 as per FN 942017-5 and EN 60068-2-27
- Protection against direct and indirect contact: PELV
- Max. cable length: 30 m outputs - Shielded
- LABS (PWIS) conformity: VDMA24364 zone III
- CE marking (see declaration of conformity): As per EU EMC directive - As per EU RoHS directive
- UKCA marking (see declaration of conformity): To UK RoHS instructions
- KC characters: KC EMC
- Certification: RCM compliance mark, c UL us - Listed (OL)
- Certificate issuing authority: UL E239998
- Note on materials: RoHS-compliant
- Housing material: PA
- Material of screws: Steel, galvanized
- Diagnostics via LED: Faults per channel - Faults per module
- Diagnostics via bus: Actuator supply short circuit/overload - Analog output short circuit/overload - Parameterization error - Nominal range was exceeded - Nominal range not reached - Load supply undervoltage - General error
- Max. address capacity outputs: 8 byte
- No. of outputs: 4
- Module parameters: Response to actuator supply short circuit/overload - Response to analog output short circuit/overload
- Channel parameters: Forcing channel x - Enable wire break/idling diagnostics - Enable parameterization error diagnostics - Enable overload/short circuit diagnostics - Signal range per channel
- Power supply, type of connection: Terminal strip
- Power supply, connection technology: Spring-loaded terminal
- Power supply, connection pattern: 00995847
- Power supply, number of pins/wires: 4
- Nominal operating voltage DC load: 24 V
- Permissible voltage fluctuations load: ± 25 %
- Nominal operating voltage DC for electronics/sensors: 24 V
- Permissible voltage fluctuations for electronics/sensors: ± 25 %
- Power supply, conductor diameter: 0.2 mm² ... 1.5 mm²
- Power supply, information on conductor diameter: 0.2 - 2.5 mm² for flexible conductors without cable end sleeves
- Intrinsic current consumption at nominal operating voltage for electronics/sensors: Typically 60 mA
- Intrinsic current consumption at nominal operating voltage load: Typically 15 mA
- Power failure buffering: 10 ms
- Reverse polarity protection: 24 V actuator supply against 0 V sensor supply - 24 V load against 0 V load - 24 V sensor supply against 0 V sensor supply
- Electrical connection output, function: Analog output
- Electrical connection output, connection type: 4x terminal strip
- Electrical connection output, connection technology: Spring-loaded terminal
- Electrical output connection, number of pins/wires: 4
- Electrical connection for output, connection pattern: 00995841
- Electrical connection for output, conductor cross section: 0.2 mm² ... 1.5 mm²
- Electrical connection for output, information on conductor cross section: 0.2 - 2.5 mm² for flexible conductors without cable end sleeves
- Electrical connection output 2, function: Functional ground
- Electrical connection output 2, connection type: Terminal strip
- Electrical connection output 2, connection technology: Spring-loaded terminal
- Electrical output connection 2, number of pins/wires: 4
- Electrical connection for output 2, connection pattern: 00995842
- Electrical connection for output 2, conductor cross section: 0.2 mm² ... 1.5 mm²
- Electrical connection for output 2, Information on conductor cross section: 0.2 - 2.5 mm² for flexible conductors without cable end sleeves
- Behavior after end of overload of the outputs: No automatic return (default) - Parameterizable (module by module)
- Max. residual current of outputs per module: 2 A
- Measured variable: Voltage - Current
- Data format: 15 bit + sign - Linear scaling
- Signal range: -10 - 10 V, -5 - 5 V, 0 - 10 V, -20 - 20 mA, 0 - 20 mA, 4 - 20 mA
- Repetition accuracy: ±0.05 % at 25 °C
- Basic error limit at 25°C: ±0.1 %
- Operating error limit related to the ambient temperature range: ±0.3 %
- Electrical isolation between channels: No
- Electrical isolation between channel and internal bus: Yes
- Fuse protection (short circuit): Internal electronic fuse per module
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on CPX-E-4AO-U-I . Santa Clara Systems carries 9,904 items from Festo.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
- 4080494
Common Typos
- CPX-E-4A0-U-1
- CPX-E-4A0-U-I
- CPX-E-4A0-U-L
- CPX-E-4AO-U-1
- CPX-E-4AO-U-L
Appended Numbers
- CPX-E-4AO-U-I-A
- CPX-E-4AO-U-I-B
- CPX-E-4AO-U-I-C
- CPX-E-4AO-U-I-D
- CPX-E-4AO-U-I-E
- CPX-E-4AO-U-I-F
- CPX-E-4AO-U-I-G
- CPX-E-4AO-U-I-H
- CPX-E-4AO-U-I-I
- CPX-E-4AO-U-I-J
- CPX-E-4AO-U-I-K
- CPX-E-4AO-U-I-L
- CPX-E-4AO-U-I-M
- CPX-E-4AO-U-I-N
- CPX-E-4AO-U-I-O
- CPX-E-4AO-U-I-P
- CPX-E-4AO-U-I-Q
- CPX-E-4AO-U-I-R
- CPX-E-4AO-U-I-S
- CPX-E-4AO-U-I-T
- CPX-E-4AO-U-I-U
- CPX-E-4AO-U-I-V
- CPX-E-4AO-U-I-W
- CPX-E-4AO-U-I-X
- CPX-E-4AO-U-I-Y
- CPX-E-4AO-U-I-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier