LS-5041
In stock and ready to ship
Product Summary:
- Weight: Approx 1.4 kg (including base)
- Type: Separate display
- Light source - Output: 0.8 mW (FDA (CDRH) Part 1040.10), 130 µW (IEC 60825-1)
- Light source - Pulse duration: 63 µs
- Light source - Wavelength: 670 nm
Get a Quote
Current response time:
13 Minutes 4 Seconds
- Description: Sensor Head Laser
- Weight: Approx 1.4 kg (including base)
- Footnotes: *1 When a round rod 10 mm 0.39? in diameter is measured in a 10 mm x 20 mm 0.39? x 0.79? measuring area. *2 When the average number of measurements is set to 768 in a 10 mm x 20 mm 0.39? x 0.79? measuring area. *3 The I/O board is optional. BCD output is available as an option. Please inquire with KEYENCE. *4 The I/O board is optional.BCD output is available as an option. Please inquire with KEYENCE. *5 The I/O board and BCD board are supported as optional accessories
- Type: Separate display
- Light source - Output: 0.8 mW (FDA (CDRH) Part 1040.10), 130 µW (IEC 60825-1)
- Light source - Pulse duration: 63 µs
- Light source - Wavelength: 670 nm
- Light source - LaserClass - FDA (CDRH)Part 1040.10: Class II Laser Product
- Light source - LaserClass - IEC 60825-1: Class 2 Laser Product
- Measurement accuracy: ±2 µm max. *1 ±0.000079"
- Repeatability: ±0.3 µm max. *2 ±0.000012"
- Display repeatability: 0.05 µm
- Laser scan rate: 1200 scans/sec
- Laser scan velocity: 121 m 397.0'/sec
- Laser scan range: Approx 46 mm 1.81"
- Light source - Type: Red semiconductor laser (655 nm), 130µW output, Class 2 Laser Product (JIS C 6802)
- Terminal blockinput - Program switching input: Non-voltage input (contact/solid state)
- Terminal blockinput - Laser remote input: Non-voltage input (contact/solid state)
- Interface - RS-232C: Measurement data output and control output
- I/O board - Analog output: ±10 V Output impedance: 100 ?*3
- I/O board - 7-level comparator output: Maximum NPN open-collector output: 100 mA (40 V) *3
- I/O board - Timing input hold reset input auto-zero settings/reset input: Non-voltage input (contact/solid state)*4
- BCD board - BCD output: Measured data output (8 digits), maximum NPN open-collector output: 40 mA (30 V)*5
- Major functions: Measurement trend display, measurement status monitor, various measurement modes, self-timing, averaging, freely combinable calculation modes, measurement modes geared toward online operation, 16-program memory, etc.
- Rating - Power voltage: 24 VDC ± 10%, ripple (P-P): 10% or less
- Rating - Current consumption.: 1.4A or less
- Environmental resistance - Enclosure rating: IP64
- Environmental resistance - Operating temperature range: 0 to +45°C 32 to 113°F
- Environmental resistance - Operating ambient humidity: 35 to 85%, No condensation
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LS-5041 . Santa Clara Systems carries 2,147 items from Keyence.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
Common Typos
- 1S-5041
- 1S-504I
- 1S-504L
- L5-5041
- L5-504I
- L5-504L
- L5-5O41
- L5-5O4I
- L5-5O4L
- L5-S041
- L5-S04I
- L5-S04L
- L5-SO41
- L5-SO4I
- L5-SO4L
- LS-504I
- LS-504L
- LS-5O41
- LS-5O4I
- LS-5O4L
- LS-S041
- LS-S04I
- LS-S04L
- LS-SO41
- LS-SO4I
- LS-SO4L
Appended Numbers
- LS-5041-A
- LS-5041-B
- LS-5041-C
- LS-5041-D
- LS-5041-E
- LS-5041-F
- LS-5041-G
- LS-5041-H
- LS-5041-I
- LS-5041-J
- LS-5041-K
- LS-5041-L
- LS-5041-M
- LS-5041-N
- LS-5041-O
- LS-5041-P
- LS-5041-Q
- LS-5041-R
- LS-5041-S
- LS-5041-T
- LS-5041-U
- LS-5041-V
- LS-5041-W
- LS-5041-X
- LS-5041-Y
- LS-5041-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier

