8501-XDO20V62
Out of Stock
Product Summary:
- Electrical connection: Screw clamp terminals
- Range of product: 8501X
- [Uc] control circuit voltage: 115/125 V DC
- Ambient air temperature for operation: -40...160 °F
- Relay type: Control
Let Us Find It
Current response time:
4 Minutes 19 Seconds
- Description: NEMA Control Relay
- Electrical connection: Screw clamp terminals
- Range of product: 8501X
- [Uc] control circuit voltage: 115/125 V DC
- Ambient air temperature for operation: -40...160 °F
- Relay type: Control
- Control circuit voltage limits: 0.8...1.1 Uc operational DC
- Product certifications: UL listed file E78403 CCN NKCRCSA LR60905 class 3211 03
- Product or component type: Relay
- Rated breaking capacity: 6 A at: 120 V AC for inductive load control circuit per UL 5083 A at: 240 V AC for inductive load control circuit per UL 5081.5 A at: 480 V AC for inductive load control circuit per UL 5081.2 A at: 600 V AC for inductive load control circuit per UL 50810 A at: <= 600 V AC for resistive load control circuit per UL 5081.1 A at: 125 V DC for inductive load control circuit per UL 5080.55 A at: 250 V DC for inductive load control circuit per UL 5080.2 A at: 301...600 V DC for inductive load control circuit per UL 5084 A at: 125 V DC for resistive load control circuit per UL 5080.8 A at: 250 V DC for resistive load control circuit per UL 508
- [In] rated current: 10 A AC5 A DC
- [Icm] rated short-circuit making capacity: 60 A at: 120 V AC for inductive load control circuit per UL 50830 A at: 240 V AC for inductive load control circuit per UL 50815 A at: 480 V AC for inductive load control circuit per UL 50812 A at: 600 V AC for inductive load control circuit per UL 50810 A at: <= 600 V AC for resistive load control circuit per UL 5081.1 A at: 125 V DC for inductive load control circuit per UL 5080.55 A at: 250 V DC for inductive load control circuit per UL 5080.2 A at: 301...600 V DC for inductive load control circuit per UL 5084 A at: 125 V DC for inductive load control circuit per UL 5080.8 A at: 250 V DC for resistive load control circuit per UL 508
- inrush power in W: 18 W
- hold-in power consumption in W: 18 W
- Operating time: 37 ms pick-up21 ms drop-out
- Contacts type and composition: 2 NO 2 standard contact cartridges
- AWG gauge: AWG 18...AWG 12 copper
- Tightening torque: 1.02...1.36 N.m control circuit screw terminals
- Mounting support: Panel
- Height: 3.56 in
- Width: 2.23 in
- Depth: 5.17 in
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on 8501-XDO20V62 . Santa Clara Systems carries 5,812 items from Square D.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
Common Typos
- 8501-XD020V62
- 8501-XD020V6Z
- 8501-XD020VG2
- 8501-XD020VGZ
- 8501-XD02OV62
- 8501-XD02OV6Z
- 8501-XD02OVG2
- 8501-XD02OVGZ
- 8501-XD0Z0V62
- 8501-XD0Z0V6Z
- 8501-XD0Z0VG2
- 8501-XDO20V6Z
- 8501-XDO20VG2
- 8501-XDO20VGZ
- 8501-XDO2OV62
- 8501-XDO2OV6Z
- 8501-XDO2OVG2
- 8501-XDO2OVGZ
- 8501-XDOZ0V62
- 8501-XDOZ0V6Z
- 8501-XDOZ0VG2
- 8501-XDOZ0VGZ
- 8501-XDOZOV62
- 8501-XDOZOV6Z
- 8501-XDOZOVG2
- 8501-XDOZOVGZ
Appended Numbers
- 8501-XDO20V62-A
- 8501-XDO20V62-B
- 8501-XDO20V62-C
- 8501-XDO20V62-D
- 8501-XDO20V62-E
- 8501-XDO20V62-F
- 8501-XDO20V62-G
- 8501-XDO20V62-H
- 8501-XDO20V62-I
- 8501-XDO20V62-J
- 8501-XDO20V62-K
- 8501-XDO20V62-L
- 8501-XDO20V62-M
- 8501-XDO20V62-N
- 8501-XDO20V62-O
- 8501-XDO20V62-P
- 8501-XDO20V62-Q
- 8501-XDO20V62-R
- 8501-XDO20V62-S
- 8501-XDO20V62-T
- 8501-XDO20V62-U
- 8501-XDO20V62-V
- 8501-XDO20V62-W
- 8501-XDO20V62-X
- 8501-XDO20V62-Y
- 8501-XDO20V62-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier