• Telemecanique ATV61HC16N4 Barcode

ATV61HC16N4

Let Us Find It

Current response time:

14 Minutes 28 Seconds
  • Description: SPEEDDRIVE,250HP,460V,ATV61
  • Product weight: 132.28 lb(US) (60 kg)
  • Range of product: Altivar 61
  • IP degree of protection: IP00 conforming to EN/IEC 60529IP00 conforming to EN/IEC 61800-5-1IP30 on side parts conforming to EN/IEC 60529IP30 on side parts conforming to EN/IEC 61800-5-1IP30 on the front panel conforming to EN/IEC 60529IP30 on the front panel conforming to EN/IEC 61800-5-1IP41 on upper part conforming to EN/IEC 60529IP41 on upper part conforming to EN/IEC 61800-5-1IP54 on lower part conforming to EN/IEC 60529IP54 on lower part conforming to EN/IEC 61800-5-1
  • Standards: UL Type 1EN 55011 class A group 2EN 61800-3 environments 1 category C3EN/IEC 61800-3EN 61800-3 environments 2 category C3IEC 60721-3-3 class 3C2EN/IEC 61800-5-1
  • Width: 12.6 in (320 mm)
  • Height: 36.22 in (920 mm)
  • Depth: 14.84 in (377 mm)
  • Operating altitude: <= 3280.84 ft. (1000 m) without derating3280.84...9842.52 ft. (1000...3000 m) with current derating 1 % per 100 m
  • Tightening torque: L1/R, L2/S, L3/T, U/T1, V/T2, W/T3 212.39 lbf.in (24 N.m) / 212 lb.inPA, PB 106.19 lbf.in (12 N.m) / 106 lb.inPC/-, PO, PA/+ 362.83 lbf.in (41 N.m) / 360 lb.inAI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR 5.31 lbf.in (0.6 N.m)
  • Vibration resistance: 1.5 mm peak to peak (f = 3...10 Hz) conforming to EN/IEC 60068-2-60.6 gn (f = 10...200 Hz) conforming to EN/IEC 60068-2-6
  • Shock resistance: 7 gn 11 ms conforming to EN/IEC 60068-2-27
  • Electrical connection: AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR terminal 2.5 mm² / AWG 14L1/R, L2/S, L3/T, U/T1, V/T2, W/T3 terminal 2 x 100 mm² / 2 x 250 kcmilPA, PB terminal 60 mm² / 250 kcmilPC/-, PO, PA/+ terminal 2 x 100 mm² / 2 x 250 kcmil
  • Insulation resistance: > 1 mOhm at 500 V DC for 1 minute to earth
  • motor power kW: 110 kW 3 phasesat 380...480 V
  • [Us] rated supply voltage: 380...480 V (- 15...10 %)
  • Relative humidity: 5...95 % without condensation conforming to IEC 60068-2-35...95 % without dripping water conforming to IEC 60068-2-3
  • Protection type: Drive against exceeding limit speedDrive against input phase lossDrive break on the control circuitDrive input phase breaksDrive line supply overvoltageDrive line supply undervoltageDrive overcurrent between output phases and earthDrive overheating protectionDrive overvoltages on the DC busDrive power removalDrive short-circuit between motor phasesDrive thermal protectionMotor motor phase breakMotor power removalMotor thermal protection
  • Response time: <= 100 ms in STO (Safe Torque Off)R1A, R1B, R1C <= 7 ms, tolerance +/- 0.5 msR2A, R2B <= 7 ms, tolerance +/- 0.5 ms
  • Switching frequency: 2...8 kHz adjustable2.5...8 kHz with derating factor
  • Product destination: Synchronous motorsAsynchronous motors
  • Noise level: 60.5 dB conforming to 86/188/EEC
  • Product or component type: Variable speed drive
  • Supply voltage limits: 323...528 V
  • Dielectric strength: 3535 V DC between earth and power terminals5092 V DC between control and power terminals
  • Product specific application: Pumping and ventilation machine
  • Supply frequency: 50...60 Hz (- 5...5 %)
  • Electromagnetic compatibility: Conforming to IEC 61000-4-2 level 3Conforming to IEC 61000-4-11Conforming to IEC 61000-4-6 level 3Conforming to IEC 61000-4-3 level 3Conforming to IEC 61000-4-4 level 4
  • Component name: ATV61
  • Network frequency: 47.5...63 Hz
  • Continuous output current: 215 A at 2.5 kHz, 380 V 3 phases215 A at 2.5 kHz, 460 V 3 phases
  • Product certifications: C-TickULCSADNVNOM 117GOST
  • Motor power hp: 150 hp 3 phasesat 380...480 V
  • Output frequency: 0.1...500 Hz
  • Pollution degree: 3 conforming to EN/IEC 61800-5-13 conforming to UL 840
  • Speed range: 1...100 in open-loop mode, without speed feedback
  • Phase: 3 phases
  • Speed accuracy: +/- 10 % of nominal slip 0.2 Tn to Tn torque variation without speed feedback
  • Line current: 168 Afor 480 V 3 phases 110 kW / 150 hp202 Afor 380 V 3 phases 110 kW / 150 hp
  • Torque accuracy: +/- 15 % in open-loop mode, without speed feedback
  • EMC filter: Level 3 EMC filter
  • Transient overtorque: 130 % of nominal motor torque, +/- 10 %for 60 s
  • Variant: Without DC choke
  • Braking torque: 30 % without braking resistor<= 125 % with braking resistor
  • Ambient air temperature for operation: 14...113 °F (-10...45 °C) without derating113...140 °F (45...60 °C) with derating factor
  • Assembly style: With heat sink
  • Regulation loop: Frequency PI regulator
  • Ambient air temperature for storage: -13...158 °F (-25...70 °C)
  • Apparent power: 133 kVAfor 380 V 3 phases 110 kW / 150 hp
  • Motor slip compensation: Automatic whatever the loadNot available in voltage/frequency ratio (2 or 5 points)Can be suppressedAdjustable
  • prospective line Isc: 35 kA 3 phases
  • Local signaling: 1 LED red presence of drive voltage
  • Maximum transient current: 258 A for 60 s 3 phases
  • Output voltage: <= power supply voltage
  • Nominal switching frequency: 2.5 kHz
  • Isolation: Between power and control terminals
  • Type of cable: With an IP21 or an IP31 kit: 3-strand IEC cableat 104 °F (40 °C), copper 70 °C PVCWithout mounting kit: 1-strand IEC cableat 113 °F (45 °C), copper 70 °C PVCWithout mounting kit: 1-strand IEC cableat 113 °F (45 °C), copper 90 °C XLPE/EPRWith UL Type 1 kit: 3-strand UL 508 cableat 104 °F (40 °C), copper 75 °C PVC
  • Asynchronous motor control profile: Voltage/frequency ratio - Energy Saving, quadratic U/fVoltage/frequency ratio, 2 pointsVoltage/frequency ratio, 5 pointsFlux vector control without sensor, standard
  • Synchronous motor control profile: Vector control without sensor, standard
  • Communication port protocol: ModbusCANopen
  • Supply: Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <= 10 mA for overload and short-circuit protectionInternal supply 24 V DC (21...27 V), <= 200 mA for overload and short-circuit protectionExternal supply 24 V DC (19...30 V)
  • Type of polarization: No impedance Modbus
  • Analogue input number: 2
  • Option card: APOGEE FLN communication cardBACnet communication cardCC-Link communication cardController inside programmable cardDeviceNet communication cardEthernet/IP communication cardFipio communication cardI/O extension cardInterbus-S communication cardLonWorks communication cardMETASYS N2 communication cardModbus Plus communication cardModbus TCP communication cardModbus/Uni-Telway communication cardMulti-pump cardProfibus DP communication cardProfibus DP V1 communication card
  • Analogue input type: AI1-/Al1+ bipolar differential voltage +/- 10 V DC, input voltage 24 V max, resolution 11 bits + signAI2 software-configurable current 0...20 mA, impedance 242 Ohm, resolution 11 bitsAI2 software-configurable voltage 0...10 V DC, input voltage 24 V max, impedance 30000 Ohm, resolution 11 bits
  • Sampling duration: Discrete input LI6 (if configured as logic input) 2 ms, +/- 0.5 msAnalog input AI1-/Al1+ 2 ms, +/- 0.5 msAnalog input Al2 2 ms, +/- 0.5 msAnalog output AO1 2 ms, +/- 0.5 msDiscrete input LI1...LI5 2 ms, +/- 0.5 ms
  • Accuracy: AI1-/Al1+ +/- 0.6 % for a temperature variation 60 °CAI2 +/- 0.6 % for a temperature variation 60 °CAO1 +/- 1 % for a temperature variation 60 °C
  • Linearity error: AI1-/Al1+ +/- 0.15 % of maximum valueAI2 +/- 0.15 % of maximum valueAO1 +/- 0.2 %
  • Analogue output number: 1
  • Analogue output type: AO1 software-configurable current, analogue output range 0...20 mA, impedance 500 Ohm, resolution 10 bitsAO1 software-configurable logic output 10 V, <= 20 mAAO1 software-configurable voltage, analogue output range 0...10 V DC, impedance 470 Ohm, resolution 10 bits
  • Discrete output number: 2
  • Discrete output type: (R1A, R1B, R1C) configurable relay logic NO/NC, electrical durability 100000 cycles(R2A, R2B) configurable relay logic NO, electrical durability 100000 cycles
  • Minimum switching current: Configurable relay logic 3 mAat 24 V DC
  • Maximum switching current: R1, R2 on resistive load, 5 A at 30 V DC, cos phi = 1, 0 msR1, R2 on inductive load, 2 A at 30 V DC, cos phi = 0.4, 7 msR1, R2 on resistive load, 5 A at 250 V AC, cos phi = 1, 0 msR1, R2 on inductive load, 2 A at 250 V AC, cos phi = 0.4, 7 ms
  • Discrete input number: 7
  • Discrete input type: (LI1...LI5) programmable, 24 V DC, voltage limits <= 30 V, with level 1 PLC, impedance 3500 Ohm(LI6) switch-configurable, 24 V DC, voltage limits <= 30 V, with level 1 PLC, impedance 3500 Ohm(LI6) switch-configurable PTC probe, 0...6, impedance 1500 Ohm(PWR) safety input, 24 V DC, voltage limits <= 30 V, impedance 1500 Ohm
  • Discrete input logic: LI1...LI5 positive logic (source), < 5 V (state 0), > 11 V (state 1)LI1...LI5 negative logic (sink), > 16 V (state 0), < 10 V (state 1)LI6 (if configured as logic input) negative logic (sink), > 16 V (state 0), < 10 V (state 1)LI6 (if configured as logic input) positive logic (source), < 5 V (state 0), > 11 V (state 1)
  • Acceleration and deceleration ramps: S, U or customizedLinear adjustable separately from 0.01 to 9000 sAutomatic adaptation of ramp if braking capacity exceeded, by using resistor
  • Braking to standstill: By DC injection
  • Frequency resolution: Analog input 0.024/50 HzDisplay unit 0.1 Hz
  • Connector type: 1 RJ45 Modbus on front face1 RJ45 Modbus on terminalMale SUB-D 9 on RJ45 CANopen
  • Physical interface: 2-wire RS 485 Modbus
  • Transmission frame: RTU Modbus
  • Transmission rate: 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal9600 bps, 19200 bps Modbus on front face
  • Data format: 8 bits, 1 stop, even parity Modbus on front face8 bits, odd even or no configurable parity Modbus on terminal
  • Number of addresses: 1...247 Modbus1...127 CANopen
  • Method of access: Slave CANopen
  • Marking: CE
  • Operating position: Vertical +/- 10 degree
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on ATV61HC16N4 . Santa Clara Systems carries 10,431 items from Telemecanique.
  • Atv61
  • Speeddrive
  • 250hp
  • 460v

Alternates

    Common Typos

    • ATV61HC1GN4
    • ATV61HCI6N4
    • ATV61HCIGN4
    • ATV61HCL6N4
    • ATV61HCLGN4
    • ATV6IHC16N4
    • ATV6IHC1GN4
    • ATV6IHCI6N4
    • ATV6IHCIGN4
    • ATV6IHCL6N4
    • ATV6IHCLGN4
    • ATV6LHC16N4
    • ATV6LHC1GN4
    • ATV6LHCI6N4
    • ATV6LHCIGN4
    • ATV6LHCL6N4
    • ATV6LHCLGN4
    • ATVG1HC16N4
    • ATVG1HC1GN4
    • ATVG1HCI6N4
    • ATVG1HCIGN4
    • ATVG1HCL6N4
    • ATVG1HCLGN4
    • ATVGIHC16N4
    • ATVGIHC1GN4
    • ATVGIHCI6N4

    Appended Numbers

    • ATV61HC16N4-A
    • ATV61HC16N4-B
    • ATV61HC16N4-C
    • ATV61HC16N4-D
    • ATV61HC16N4-E
    • ATV61HC16N4-F
    • ATV61HC16N4-G
    • ATV61HC16N4-H
    • ATV61HC16N4-I
    • ATV61HC16N4-J
    • ATV61HC16N4-K
    • ATV61HC16N4-L
    • ATV61HC16N4-M
    • ATV61HC16N4-N
    • ATV61HC16N4-O
    • ATV61HC16N4-P
    • ATV61HC16N4-Q
    • ATV61HC16N4-R
    • ATV61HC16N4-S
    • ATV61HC16N4-T
    • ATV61HC16N4-U
    • ATV61HC16N4-V
    • ATV61HC16N4-W
    • ATV61HC16N4-X
    • ATV61HC16N4-Y
    • ATV61HC16N4-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo