GB2DB05
In stock and ready to ship
Product Summary:
- Product weight: 0.25 lb(US) (0.115 kg)
- IP degree of protection: IP20 conforming to IEC 60529
- Standards: EN 60947-1EN 60947-2IEC 60947-1IEC 60947-2
- Device short name: GB2
- Width: 1.18 in (30 mm)
Get a Quote
Current response time:
6 Minutes 37 Seconds
- Description: Circuit Protector
- Product weight: 0.25 lb(US) (0.115 kg)
- IP degree of protection: IP20 conforming to IEC 60529
- Standards: EN 60947-1EN 60947-2IEC 60947-1IEC 60947-2
- Device short name: GB2
- Width: 1.18 in (30 mm)
- Height: 2.91 in (74 mm)
- Depth: 2.76 in (70 mm)
- Protective treatment: TC
- [Uimp] rated impulse withstand voltage: 4 kV conforming to IEC 60947-2
- Operating altitude: 9842.52 ft. (3000 m)
- Mechanical durability: 8000 cycles
- Tightening torque: 10.62 lbf.in (1.2 N.m) - on connector
- Connections - terminals: Connector 1 cable(s) 0...0.01 in² (0.75...6 mm²) - cable stiffness : solid - without cable endConnector 2 cable(s) 0...0.01 in² (0.75...4 mm²) - cable stiffness : solid - without cable endConnector 1 cable(s) 0...0.01 in² (0.75...4 mm²) - cable stiffness : flexible - with cable endConnector 2 cable(s) 0...0 in² (0.75...2.5 mm²) - cable stiffness : flexible - with cable end
- Range: TeSys
- Mounting support: RailPlate
- System Voltage: 277 V AC 50/60 Hz conforming to CSA C22.2 No 14415 V AC 50/60 Hz conforming to IEC 60947-2277 V AC 50/60 Hz conforming to UL 1077
- Product name: TeSys GB2
- Electrical durability: 8000 cycles
- Utilization category: Category A conforming to IEC 60947-2DC-12 conforming to IEC 60947-5-1DC-13 conforming to IEC 60947-5-1
- Poles description: 2P
- Control type: Toggle
- Breaking capacity: Icu = 50 kAat 400/415 V AC 50/60 Hz conforming to IEC 60947-2Icu = 50 kAat 230/240 V AC 50/60 Hz conforming to IEC 60947-2Icu = 1 kAat 48 V DC conforming to IEC 60947-2Icu = 50 kAat 110 V AC 50/60 Hz conforming to IEC 60947-2Icu = 1.5 kAat 24 V DC conforming to IEC 60947-2
- Mounting position: VerticalHorizontal
- Mounting mode: By clips
- Product or component type: Circuit breaker
- Ambient air temperature for operation: -4...140 °F (-20...60 °C)
- Device application: Control
- [In] rated current: 0.5 A
- Ambient air temperature for storage: -40...176 °F (-40...80 °C)
- Fire resistance: 1760 °F (960 °C) conforming to IEC 60695-2-1
- Network type: AC/DC
- Power dissipation per pole: 2 W
- Network frequency: 50/60 Hz conforming to IEC 60947-2
- [Ics] rated service short-circuit breaking capacity: 100 %at 110 V AC 50/60 Hz conforming to IEC 60947-225 %at 230/240 V AC 50/60 Hz conforming to IEC 60947-225 %at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
- Trip unit technology: Thermal-magnetic
- Magnetic tripping current: 6.6 A
- Mechanical robustness: Shocks 22 Gn for 20 ms conforming to IEC 60068-2-27Vibrations 5 Gn, 5...110 Hz conforming to IEC 60068-2-6
- Quantity per set: Set of 3
- 9 mm pitches: 4
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GB2DB05 . Santa Clara Systems carries 10,643 items from Telemecanique.
- Tesys Gb2 - Thermal-Magnetic Circuit Breaker - 2p - 0.5 A - Id = 6.6 A
Alternates
Common Typos
- G82D805
- G82D80S
- G82D8O5
- G82D8OS
- G82DB05
- G82DB0S
- G82DBO5
- G82DBOS
- G8ZDB05
- G8ZDB0S
- G8ZDBO5
- GB2D805
- GB2D80S
- GB2D8O5
- GB2D8OS
- GB2DB0S
- GB2DBO5
- GB2DBOS
- GBZD805
- GBZD80S
- GBZD8O5
- GBZD8OS
- GBZDB05
- GBZDB0S
- GBZDBO5
- GBZDBOS
Appended Numbers
- GB2DB05-A
- GB2DB05-B
- GB2DB05-C
- GB2DB05-D
- GB2DB05-E
- GB2DB05-F
- GB2DB05-G
- GB2DB05-H
- GB2DB05-I
- GB2DB05-J
- GB2DB05-K
- GB2DB05-L
- GB2DB05-M
- GB2DB05-N
- GB2DB05-O
- GB2DB05-P
- GB2DB05-Q
- GB2DB05-R
- GB2DB05-S
- GB2DB05-T
- GB2DB05-U
- GB2DB05-V
- GB2DB05-W
- GB2DB05-X
- GB2DB05-Y
- GB2DB05-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier
