LC1DT80AV7
Out of Stock
Product Summary:
- Product weight: 2.54 lb(US) (1.15 kg)
- Range of product: TeSys D
- IP degree of protection: IP20 front face conforming to IEC 60529
- Standards: CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
- Device short name: LC1D
Let Us Find It
Current response time:
12 Minutes 6 Seconds
- Description: Contactor
- Product weight: 2.54 lb(US) (1.15 kg)
- Range of product: TeSys D
- IP degree of protection: IP20 front face conforming to IEC 60529
- Standards: CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
- Device short name: LC1D
- Width: 2.76 in (70 mm)
- Height: 4.8 in (122 mm)
- Depth: 4.72 in (120 mm)
- Protective treatment: TH conforming to IEC 60068-2-30
- [Ui] rated insulation voltage: 600 V power circuit certifications CSA600 V power circuit certifications UL690 V power circuit conforming to IEC 60947-4-1690 V signaling circuit conforming to IEC 60947-1600 V signaling circuit certifications CSA600 V signaling circuit certifications UL
- [Uimp] rated impulse withstand voltage: Conforming to IEC 60947
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Mechanical durability: 6 Mcycles
- Tightening torque: Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 70.8 lbf.in (8 N.m) - on screw clamp terminals - cable 0.04...0.05 in² (25...35 mm²) hexagonal 0.16 in (4 mm)Power circuit : 5 N.m - on screw clamp terminals - cable 1...25 mm² hexagonal 4 mm
- Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 0...0.05 in² (1...35 mm²) - cable stiffness: flexible - without cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 0...0.05 in² (1...35 mm²) - cable stiffness: flexible - with cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 0...0.05 in² (1...35 mm²) - cable stiffness: solid - without cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 0...0.04 in² (1...25 mm²) - cable stiffness: flexible - without cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 0...0.04 in² (1...25 mm²) - cable stiffness: flexible - with cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 0...0.04 in² (1...25 mm²) - cable stiffness: solid - without cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
- Range: TeSys
- Mounting support: RailPlate
- [Ith] conventional free air thermal current: 80 A at <= 140 °F (60 °C) power circuit10 A at <= 140 °F (60 °C) signaling circuit
- System Voltage: <= 300 V DC power circuit<= 690 V AC 25...400 Hz power circuit
- Operating rate: 3600 cyc/h at <= 140 °F (60 °C)
- Product name: TeSys D
- [Uc] control circuit voltage: 400 V AC 50/60 Hz
- Electrical durability: 1.4 Mcycles 80 A AC-1 at Ue <= 440 V
- Insulation resistance: > 10 MOhm signaling circuit
- [Ie] rated operational current: 80 A (<= 140 °F (60 °C)) at <= 440 V AC AC-1 power circuit
- Utilization category: AC-1
- Control circuit voltage limits: 0.3...0.6 Uc drop-out at 140 °F (60 °C), AC 50/60 Hz0.8...1.1 Uc operational at 140 °F (60 °C), AC 50 Hz0.85...1.1 Uc operational at 140 °F (60 °C), AC 60 Hz
- Poles description: 4P
- Overvoltage category: III
- Operating time: 12...26 ms closing4...19 ms opening
- Associated fuse rating: 125 A gG at <= 690 V coordination type 1 power circuit125 A gG at <= 690 V coordination type 2 power circuit10 A gG signaling circuit conforming to IEC 60947-5-1
- Control circuit type: AC 50/60 Hz
- Coil technology: Without built-in suppressor module
- inrush power in VA: 140 VA at 68 °F (20 °C) (cos ? 0.75) 60 Hz160 VA at 68 °F (20 °C) (cos ? 0.75) 50 Hz
- Pollution degree: 3
- Product or component type: Contactor
- hold-in power consumption in VA: 13 VA at 68 °F (20 °C) (cos ? 0.3) 60 Hz15 VA at 68 °F (20 °C) (cos ? 0.3) 50 Hz
- Ambient air temperature for operation: 23...140 °F (-5...60 °C)
- Heat dissipation: 4...5 W at 50/60 Hz
- Ambient air temperature for storage: -76...176 °F (-60...80 °C)
- Contactor application: Resistive load
- Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1
- Permissible ambient air temperature around the device: -40...158 °F (-40...70 °C) at Uc
- Signaling circuit frequency: 25...400 Hz
- Minimum switching current: 5 mA signaling circuit
- Fire resistance: 1562 °F (850 °C) conforming to IEC 60695-2-1
- Pole contact composition: 4 NO
- Minimum switching voltage: 17 V signaling circuit
- Flame retardance: V1 conforming to UL 94
- Non-overlap time: 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact)
- Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor open 10 Gn for 11 msShocks contactor closed 15 Gn for 11 ms
- Auxiliary contact composition: 1 NO + 1 NC
- Irms rated making capacity: 1000 A at 440 V power circuit conforming to IEC 60947140 A AC signaling circuit conforming to IEC 60947-5-1250 A DC signaling circuit conforming to IEC 60947-5-1
- Rated breaking capacity: 1000 A at 440 V power circuit conforming to IEC 60947
- [Icw] rated short-time withstand current: 100 A 1 s signaling circuit120 A 500 ms signaling circuit140 A 100 ms signaling circuit520 A <= 104 °F (40 °C) 10 s power circuit900 A <= 104 °F (40 °C) 1 s power circuit110 A <= 104 °F (40 °C) 10 min power circuit260 A <= 104 °F (40 °C) 1 min power circuit
- Average impedance: 1.6 mOhm at 50 Hz - Ith 80 A power circuit
- Power dissipation per pole: 10.2 W AC-1
- Protective cover: With
- Product certifications: CCCLROS (Lloyds register of shipping)GLCSADNVBVULRINAGOST
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1DT80AV7 . Santa Clara Systems carries 10,643 items from Telemecanique.
- Tesys D Contactor - 4p(4 No) - Ac-1 - <= 440 V 80 A - 400 V Ac 50/60 Hz Coil
Alternates
Common Typos
- 1C1DT80AV7
- 1C1DT8OAV7
- 1C1DTB0AV7
- 1C1DTBOAV7
- 1CIDT80AV7
- 1CIDT8OAV7
- 1CIDTB0AV7
- 1CIDTBOAV7
- 1CLDT80AV7
- 1CLDT8OAV7
- 1CLDTB0AV7
- 1CLDTBOAV7
- IC1DT80AV7
- IC1DT8OAV7
- IC1DTB0AV7
- LC1DT8OAV7
- LC1DTB0AV7
- LC1DTBOAV7
- LCIDT80AV7
- LCIDT8OAV7
- LCIDTB0AV7
- LCIDTBOAV7
- LCLDT80AV7
- LCLDT8OAV7
- LCLDTB0AV7
- LCLDTBOAV7
Appended Numbers
- LC1DT80AV7-A
- LC1DT80AV7-B
- LC1DT80AV7-C
- LC1DT80AV7-D
- LC1DT80AV7-E
- LC1DT80AV7-F
- LC1DT80AV7-G
- LC1DT80AV7-H
- LC1DT80AV7-I
- LC1DT80AV7-J
- LC1DT80AV7-K
- LC1DT80AV7-L
- LC1DT80AV7-M
- LC1DT80AV7-N
- LC1DT80AV7-O
- LC1DT80AV7-P
- LC1DT80AV7-Q
- LC1DT80AV7-R
- LC1DT80AV7-S
- LC1DT80AV7-T
- LC1DT80AV7-U
- LC1DT80AV7-V
- LC1DT80AV7-W
- LC1DT80AV7-X
- LC1DT80AV7-Y
- LC1DT80AV7-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier