LC1F500G7
In stock and ready to ship
Product Summary:
- Product weight: 25.02 lb(US) (11.35 kg)
- Standards: JIS C8201-4-1EN 60947-1EN 60947-4-1IEC 60947-1IEC 60947-4-1
- Device short name: LC1F
- Width: 9.17 in (233 mm)
- Height: 9.37 in (238 mm)
Get a Quote
Current response time:
14 Minutes 17 Seconds
- Description: Contactor
- Product weight: 25.02 lb(US) (11.35 kg)
- IP degree of protection: IP20 front face with shrouds (ordered separately) conforming to IEC 60529IP20 front face with shrouds (ordered separately) conforming to VDE 0106
- Standards: JIS C8201-4-1EN 60947-1EN 60947-4-1IEC 60947-1IEC 60947-4-1
- Device short name: LC1F
- Width: 9.17 in (233 mm)
- Height: 9.37 in (238 mm)
- Depth: 9.13 in (232 mm)
- Protective treatment: TH
- [Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C
- [Uimp] rated impulse withstand voltage: 8 kV
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Mechanical durability: 10 Mcycles
- Tightening torque: Power circuit: 309.73 lbf.in (35 N.m)Control circuit: 10.62 lbf.in (1.2 N.m)
- Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endPower circuit: lugs-ring terminals 2 cable(s) 0.37 in² (240 mm²)Power circuit : bolted connectionPower circuit : bar 2 x (40 x 5 mm)
- Range: TeSys
- Mounting support: Plate
- [Ith] conventional free air thermal current: 700 A at <= 104 °F (40 °C)
- System Voltage: <= 1000 V AC 50/60 Hz<= 460 V DC
- Operating rate: 2400 cyc/h at <= 131 °F (55 °C)
- Product name: TeSys F
- [Uc] control circuit voltage: 120 V AC 40...400 Hz
- motor power kW: 250 kW at 380...400 V AC 50/60 Hz AC-3280 kW at 415 V AC 50/60 Hz AC-3295 kW at 440 V AC 50/60 Hz AC-3355 kW at 500 V AC 50/60 Hz AC-3335 kW at 1000 V AC 50/60 Hz AC-3147 kW at 220...230 V AC 50/60 Hz AC-380 kW at 400 V AC 50/60 Hz AC-4335 kW at 660...690 V AC 50/60 Hz AC-3
- [Ie] rated operational current: 700 A (<= 104 °F (40 °C)) at <= 440 V AC AC-1500 A (<= 131 °F (55 °C)) at <= 440 V AC AC-3
- Utilization category: AC-1AC-4AC-3
- Control circuit voltage limits: 0.85...1.1 Uc at 131 °F (55 °C) operational 40...400 Hz0.3...0.5 Uc at 131 °F (55 °C) drop-out 40...400 Hz
- Poles description: 3P
- Overvoltage category: III
- Operating time: 100...170 ms opening40...65 ms closing
- Associated fuse rating: 500 A aM at <= 440 V800 A gG at <= 440 V
- Product or component type: Contactor
- Ambient air temperature for operation: 23...131 °F (-5...55 °C)
- Rated breaking capacity: 4000 A conforming to IEC 60947-4-1
- Ambient air temperature for storage: -76...176 °F (-60...80 °C)
- Contactor application: Resistive loadMotor control
- [Icw] rated short-time withstand current: 4200 A <= 104 °F (40 °C) 10 s3200 A <= 104 °F (40 °C) 30 s2400 A <= 104 °F (40 °C) 1 min1500 A <= 104 °F (40 °C) 3 min1200 A <= 104 °F (40 °C) 10 min
- Permissible ambient air temperature around the device: -40...158 °F (-40...70 °C)
- Average impedance: 0.18 mOhm at 50 Hz - Ith 700 A
- Mechanical robustness: Shocks contactor open 9 Gn for 11 msVibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor closed 15 Gn for 11 ms
- Pole contact composition: 3 NO
- Power dissipation per pole: 45 W AC-388 W AC-1
- Product certifications: BVLROS (Lloyds register of shipping)RMRoSCBABSDNVCSAULRINA
- inrush power in VA: 1100 VA at 68 °F (20 °C) (cos ? 0.9) 40...400 Hz
- hold-in power consumption in VA: 18 VA at 68 °F (20 °C) (cos ? 0.9) 40...400 Hz
- Heat dissipation: 18 W
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1F500G7 . Santa Clara Systems carries 10,643 items from Telemecanique.
- Tesys F Contactor - 3p (3 No) - Ac-3 - <= 440 V 500 A - Coil 120 V Ac
Alternates
Common Typos
- LC1F50067
- LC1F50O67
- LC1F50OG7
- LC1F5O067
- LC1F5O0G7
- LC1F5OO67
- LC1F5OOG7
- LC1FS0067
- LC1FS00G7
- LC1FS0O67
- LC1FS0OG7
- LC1FSO067
- LC1FSO0G7
- LC1FSOO67
- LC1FSOOG7
- LCIF50067
- LCIF500G7
- LCIF50O67
- LCIF50OG7
- LCIF5O067
- LCIF5O0G7
- LCIF5OO67
- LCIF5OOG7
- LCIFS0067
- LCIFS00G7
- LCIFS0OG7
Appended Numbers
- LC1F500G7-A
- LC1F500G7-B
- LC1F500G7-C
- LC1F500G7-D
- LC1F500G7-E
- LC1F500G7-F
- LC1F500G7-G
- LC1F500G7-H
- LC1F500G7-I
- LC1F500G7-J
- LC1F500G7-K
- LC1F500G7-L
- LC1F500G7-M
- LC1F500G7-N
- LC1F500G7-O
- LC1F500G7-P
- LC1F500G7-Q
- LC1F500G7-R
- LC1F500G7-S
- LC1F500G7-T
- LC1F500G7-U
- LC1F500G7-V
- LC1F500G7-W
- LC1F500G7-X
- LC1F500G7-Y
- LC1F500G7-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier