LP2K1210BD
In stock and ready to ship
Product Summary:
- Product weight: 1.06 lb(US) (0.48 kg)
- Range of product: TeSys K
- IP degree of protection: IP20 conforming to VDE 0106
- Standards: NF C 63-110VDE 0660IEC 60947BS 5424
- Device short name: LP2K
Get a Quote
Current response time:
16 Minutes 1 Second
- Description: TeSys K reversing contactor - 3P - AC-3 <= 440 V 12 A - 1 NO - 24 V DC coil
- Product weight: 1.06 lb(US) (0.48 kg)
- Range of product: TeSys K
- IP degree of protection: IP20 conforming to VDE 0106
- Standards: NF C 63-110VDE 0660IEC 60947BS 5424
- Device short name: LP2K
- Width: 3.54 in (90 mm)
- Height: 2.28 in (58 mm)
- Depth: 2.24 in (57 mm)
- Protective treatment: TC conforming to IEC 60068TC conforming to DIN 50016
- [Ui] rated insulation voltage: 690 V signaling circuit conforming to IEC 60947-4-1690 V signaling circuit conforming to IEC 60947-5-1600 V signaling circuit conforming to UL 508600 V power circuit conforming to CSA C22.2 No 14600 V signaling circuit conforming to CSA C22.2 No 14690 V power circuit conforming to IEC 60947-4-1600 V power circuit conforming to UL 508
- [Uimp] rated impulse withstand voltage: 8 kV
- Operating altitude: 6561.68 ft. (2000 m) without derating in temperature
- Mechanical durability: 5 Mcycles
- Tightening torque: 11.5 lbf.in (1.3 N.m) - on screw clamp terminals - with screwdriver Philips No 211.5 lbf.in (1.3 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
- Connections - terminals: Screw clamp terminals 1 cable(s) 0...0.01 in² (1.5...4 mm²) - cable stiffness: solidScrew clamp terminals 1 cable(s) 0...0.01 in² (0.75...4 mm²) - cable stiffness: flexible - without cable endScrew clamp terminals 1 cable(s) 0...0 in² (0.34...2.5 mm²) - cable stiffness: flexible - with cable endScrew clamp terminals 2 cable(s) 0...0.01 in² (1.5...4 mm²) - cable stiffness: solidScrew clamp terminals 2 cable(s) 0...0.01 in² (0.75...4 mm²) - cable stiffness: flexible - without cable endScrew clamp terminals 2 cable(s) 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable end
- Range: TeSys
- Mounting support: RailPlate
- [Ith] conventional free air thermal current: 20 A at <= 122 °F (50 °C) power circuit10 A at <= 122 °F (50 °C) signaling circuit
- System Voltage: 690 V AC 50/60 Hz power circuit<= 690 V AC 50/60 Hz signaling circuit
- Operating rate: 3600 cyc/h
- Product name: TeSys K
- [Uc] control circuit voltage: 24 V DC
- Electrical durability: 0.3 Mcycles 20 A AC-1 at Ue <= 440 V1.3 Mcycles 12 A AC-3 at Ue <= 440 V
- Insulation resistance: > 10 MOhm signaling circuit
- motor power kW: 3 kW at 220...230 V AC 50/60 Hz4 kW at 480 V AC 50/60 Hz4 kW at 500...600 V AC 50/60 Hz4 kW at 660...690 V AC 50/60 Hz5.5 kW at 380...415 V AC 50/60 Hz5.5 kW at 440 V AC 50/60 Hz
- [Ie] rated operational current: 20 A (<= 122 °F (50 °C)) at <= 440 V AC AC-1 power circuit16 A (<= 158 °F (70 °C)) at 690 V AC AC-1 power circuit12 A at <= 440 V AC AC-3 power circuit
- Utilization category: AC-1AC-4AC-3
- Control circuit voltage limits: 0.8...1.15 Uc at <= 122 °F (50 °C) operational0.1...0.75 Uc at <= 122 °F (50 °C) drop-out
- Poles description: 3P
- Overvoltage category: III
- Operating time: 10 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing
- Associated fuse rating: 25 A gG at <= 440 V power circuit25 A aM power circuit10 A gG signaling circuit conforming to IEC 6094710 A gG signaling circuit conforming to VDE 0660
- Control circuit type: DC standard
- inrush power in W: 3 W at 68 °F (20 °C)
- hold-in power consumption in W: 3 W at 68 °F (20 °C)
- Ambient air temperature for operation: -13...122 °F (-25...50 °C)
- Product or component type: Reversing contactor
- Heat dissipation: 3 W
- Ambient air temperature for storage: -58...176 °F (-50...80 °C)
- Auxiliary contacts type: Type instantaneous 1 NO
- Device application: Control
- Minimum switching current: 5 mA signaling circuit
- Flame retardance: V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102
- Contactor application: Motor controlResistive load
- Minimum switching voltage: 17 V signaling circuit
- Mechanical robustness: Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6Shocks contactor opened, on X axis 10 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Y axis 6 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on X axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Y axis 10 Gn for 11 ms IEC 60068-2-27
- Non overlap distance: 0.02 in (0.5 mm)
- Device presentation: Preassembled with reversing power busbar
- Pole contact composition: 3 NO
- Auxiliary contact composition: 1 NO
- Irms rated making capacity: 110 A AC signaling circuit conforming to IEC 60947144 A AC power circuit conforming to NF C 63-110144 A AC power circuit conforming to IEC 60947
- Rated breaking capacity: 110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
- [Icw] rated short-time withstand current: 25 A <= 50 °C >= 15 min power circuit80 A 1 s signaling circuit90 A 500 ms signaling circuit110 A 100 ms signaling circuit115 A <= 122 °F (50 °C) 1 s power circuit105 A <= 122 °F (50 °C) 5 s power circuit100 A <= 122 °F (50 °C) 10 s power circuit75 A <= 122 °F (50 °C) 30 s power circuit55 A <= 122 °F (50 °C) 1 min power circuit50 A <= 122 °F (50 °C) 3 min power circuit
- Average impedance: 3 mOhm at 50 Hz - Ith 20 A power circuit
- Interlocking type: Mechanical
- Product certifications: CSAUL
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LP2K1210BD . Santa Clara Systems carries 10,643 items from Telemecanique.
- Tesys K Reversing Contactor - 3p - Ac-3 <= 440 V 12 A - 1 No - 24 V Dc Coil
Alternates
Common Typos
- LP2K12108D
- LP2K121O8D
- LP2K121OBD
- LP2K12I08D
- LP2K12I0BD
- LP2K12IO8D
- LP2K12IOBD
- LP2K12L08D
- LP2K12L0BD
- LP2K12LO8D
- LP2K12LOBD
- LP2K1Z108D
- LP2K1Z10BD
- LP2K1Z1O8D
- LP2K1Z1OBD
- LP2K1ZI08D
- LP2K1ZI0BD
- LP2K1ZIO8D
- LP2K1ZIOBD
- LP2K1ZL08D
- LP2K1ZL0BD
- LP2K1ZLO8D
- LP2K1ZLOBD
- LP2KI2108D
- LP2KI210BD
- LP2KI21OBD
Appended Numbers
- LP2K1210BD-A
- LP2K1210BD-B
- LP2K1210BD-C
- LP2K1210BD-D
- LP2K1210BD-E
- LP2K1210BD-F
- LP2K1210BD-G
- LP2K1210BD-H
- LP2K1210BD-I
- LP2K1210BD-J
- LP2K1210BD-K
- LP2K1210BD-L
- LP2K1210BD-M
- LP2K1210BD-N
- LP2K1210BD-O
- LP2K1210BD-P
- LP2K1210BD-Q
- LP2K1210BD-R
- LP2K1210BD-S
- LP2K1210BD-T
- LP2K1210BD-U
- LP2K1210BD-V
- LP2K1210BD-W
- LP2K1210BD-X
- LP2K1210BD-Y
- LP2K1210BD-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier