Product Summary:
- Standards: UL 508 type E, with phase barrier
- Device short name: LU2B
- Width: 45 mm
- Height: 224 mm
- Depth: 126 mm
- Description: Power Base
- IP degree of protection: IP20 conforming to IEC 60947-1 (front panel and wired terminals)
- Standards: UL 508 type E, with phase barrier
- Device short name: LU2B
- Width: 45 mm
- Height: 224 mm
- Depth: 126 mm
- Protective treatment: TH conforming to IEC 60068
- [Ui] rated insulation voltage: 600 V conforming to UL 508
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
- Operating altitude: 2000 m
- Mechanical durability: 15000000 cycles
- Tightening torque: Control circuit: 0.8…1.2 N.m flat screwdriver 5 mm
- Connections - terminals: Control circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable end
- Range: TeSys
- [Ith] conventional free air thermal current: 32 A
- Product name: TeSys U
- [Uc] control circuit voltage: 110...220 V DC
- Shock resistance: 10 gn power poles open conforming to IEC 60068-2-27
- Vibration resistance: 2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27
- [Ie] rated operational current: 21 A at 690 V
- Control circuit voltage limits: 55 V 110...220 V DC drop-out
- Poles description: 3P
- Operating time: 150 ms with change of direction for power circuit
- Product or component type: Reversing power base
- Device application: Motor
- Utilisation category: AC-41
- Auxiliary contact composition: 1 NO + 1 NC
- Auxiliary contacts type: type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1
- [Ue] rated operational voltage: 230 V
- Network frequency: 40...60 Hz
- [Ics] rated service breaking capacity: 10 kA at 500 V
- Typical current consumption: 1000 mA at 110...220 V DC I maximum while closing
- Inrush restraint duration: 25 ms AC 50/60 Hz
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
- Maximum operating rate: 60 cyc/mn
- Net weight: 1.27 kg
- Heat dissipation: 3 W for control circuit with LUCA, LUCB, LUCC, LUCD
- Immunity to microbreaks: 3 ms
- Immunity to voltage dips: 70 % / 500 ms conforming to IEC 61000-4-11
- Ambient air temperature for operation: -25…60 °C with LUCM
- Ambient air temperature for storage: -40…85 °C
- Fire resistance: 960 °C parts supporting live components conforming to IEC 60695-2-12
- Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2
- Resistance to radiated fields: 10 V/m 3 conforming to IEC 61000-4-3
- Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4
- Immunity to radioelectric fields: 10 V conforming to IEC 61000-4-6
- Sustainable offer status: Green Premium product
- Mercury free: Yes
- Circularity Profile: End of Life Information
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LU2B32FU . Santa Clara Systems carries 10,643 items from Telemecanique.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
Common Typos
- 1U2832FU
- 1U283ZFU
- 1U2B32FU
- 1U2B3ZFU
- 1UZ832FU
- 1UZ83ZFU
- 1UZB32FU
- 1UZB3ZFU
- IU2832FU
- IU283ZFU
- IU2B32FU
- IU2B3ZFU
- IUZ832FU
- IUZ83ZFU
- IUZB32FU
- IUZB3ZFU
- LU2832FU
- LU283ZFU
- LU2B3ZFU
- LUZ832FU
- LUZ83ZFU
- LUZB32FU
- LUZB3ZFU
Appended Numbers
- LU2B32FU-A
- LU2B32FU-B
- LU2B32FU-C
- LU2B32FU-D
- LU2B32FU-E
- LU2B32FU-F
- LU2B32FU-G
- LU2B32FU-H
- LU2B32FU-I
- LU2B32FU-J
- LU2B32FU-K
- LU2B32FU-L
- LU2B32FU-M
- LU2B32FU-N
- LU2B32FU-O
- LU2B32FU-P
- LU2B32FU-Q
- LU2B32FU-R
- LU2B32FU-S
- LU2B32FU-T
- LU2B32FU-U
- LU2B32FU-V
- LU2B32FU-W
- LU2B32FU-X
- LU2B32FU-Y
- LU2B32FU-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier