CPX-AP-I-8DI-M8-3P
Product Summary:
- Ambient temperature: -20 °C ... 60 °C
- Dimensions W x L x H: 30 mm x 170 mm x 35 mm
- Type of mounting: On H-rail with accessories - With through-hole
- Storage temperature: -40 °C ... 70 °C
- Relative air humidity: 5 - 95 % - Non-condensing
Get a Quote
Current response time:
13 Minutes 38 Seconds
- Description: Digital Input Module
- Ambient temperature: -20 °C ... 60 °C
- Dimensions W x L x H: 30 mm x 170 mm x 35 mm
- Type of mounting: On H-rail with accessories - With through-hole
- Storage temperature: -40 °C ... 70 °C
- Relative air humidity: 5 - 95 % - Non-condensing
- Degree of protection: IP65 - IP67
- Note on degree of protection: Unused connections sealed
- Corrosion resistance class (CRC): 1 - Low corrosion stress
- Vibration resistance: Transport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6
- Shock resistance: Shock test with severity level 1 as per FN 942017-5 and EN 60068-2-27
- Contamination level: 2
- Overvoltage category: II
- Max. cable length: 30 m inputs - 50 m system communication
- Information on max. cable length: Power supply according to nominal voltage
- LABS (PWIS) conformity: VDMA24364-B2-L
- Cleanroom suitability, measured according to ISO 14644-14: Statically installed element, no meaningful evaluation possible according to ISO 14644-1
- CE marking (see declaration of conformity): As per EU EMC directive - As per EU RoHS directive
- UKCA marking (see declaration of conformity): To UK instructions for EMC - To UK RoHS instructions
- KC characters: KC EMC
- Certification: RCM compliance mark, c UL us - Listed (OL)
- Certificate issuing authority: UL E239998
- Note on materials: RoHS-compliant
- Housing material: PC - Die-cast zinc, nickel-plated
- O-ring material: FPM
- Diagnostics via LED: Diagnostics per module - Status per channel
- Diagnose per internal communication: Short circuit/overload in sensor supply - Electronics/sensors overvoltage - Electronics/sensors undervoltage
- Communication interface, function: System communication XF10 IN / XF20 OUT
- Communication interface, connection type: 2x socket
- Communication interface, connection technology: M8x1, D-coded as per EN 61076-2-114
- Communication interface, connection pattern: 00995937
- Communication interface, protocol: AP
- Communication interface, number of pins/wires: 4
- Communication interface, shielding: Yes
- Power supply, function: Incoming electronics/sensors and load
- Power supply, type of connection: Plug
- Power supply, connection technology: M8x1, A-coded as per EN 61076-2-104
- Power supply, connection pattern: 00991171
- Power supply, number of pins/wires: 4
- Voltage forwarding, function: Outgoing electronics/sensors and load
- Voltage forwarding, connection type: Socket
- Voltage forwarding, connection technology: M8x1, A-coded as per EN 61076-2-104
- Voltage forwarding, connection pattern: 00991872
- Voltage forwarding, number of pins/wires: 4
- Note regarding operating voltage: SELV/PELV fixed power supplies required - Note voltage drop
- Nominal operating voltage DC for electronics/sensors: 24 V
- Permissible voltage fluctuations for electronics/sensors: ± 25 %
- Max. power supply: 2 x 4 A (external fuse required)
- Intrinsic current consumption at nominal operating voltage for electronics/sensors: Typically 32 mA
- Power failure buffering: 10 ms
- Reverse polarity protection: Yes
- Electrical connection input, function: Digital input
- Electrical connection input, connection type: 8x socket
- Electrical input connection, connection technology: M8x1, A-coded as per EN 61076-2-104
- Electrical connection for input, connection pattern: 00991871
- Electrical connection, input, number of pins/wires: 3
- No. of inputs: 8
- Input characteristics: As per IEC 61131-2, type 3
- Switching level: Signal 0: <= 5 V - Signal 1: >= 11 V
- Input switching logic: PNP (positive switching) - 2-wire sensors as per IEC 61131-2 - 3-wire sensors as per IEC 61131-2
- Input debounce time: 0.1 ms - 3 ms - 10 ms - 20 ms
- Fuse protection inputs (short circuit): Internal electronic fuse per module
- Max. residual current of inputs per module: 1.8 A
- Electrical isolation of inputs between channels: No
- Digital inputs, electrical isolation of input - internal communication: Yes
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on CPX-AP-I-8DI-M8-3P . Santa Clara Systems carries 9,904 items from Festo.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
- 8086600
Common Typos
- CPX-AP-1-8D1-M8-3P
- CPX-AP-1-8D1-MB-3P
- CPX-AP-1-8DI-M8-3P
- CPX-AP-1-8DI-MB-3P
- CPX-AP-1-8DL-M8-3P
- CPX-AP-1-8DL-MB-3P
- CPX-AP-1-BD1-M8-3P
- CPX-AP-1-BD1-MB-3P
- CPX-AP-1-BDI-M8-3P
- CPX-AP-1-BDI-MB-3P
- CPX-AP-1-BDL-M8-3P
- CPX-AP-1-BDL-MB-3P
- CPX-AP-I-8D1-M8-3P
- CPX-AP-I-8D1-MB-3P
- CPX-AP-I-8DI-MB-3P
- CPX-AP-I-8DL-M8-3P
- CPX-AP-I-8DL-MB-3P
- CPX-AP-I-BD1-M8-3P
- CPX-AP-I-BD1-MB-3P
- CPX-AP-I-BDI-M8-3P
- CPX-AP-I-BDI-MB-3P
- CPX-AP-I-BDL-M8-3P
- CPX-AP-I-BDL-MB-3P
- CPX-AP-L-8D1-M8-3P
- CPX-AP-L-8DI-M8-3P
- CPX-AP-L-8DI-MB-3P
Appended Numbers
- CPX-AP-I-8DI-M8-3P-A
- CPX-AP-I-8DI-M8-3P-B
- CPX-AP-I-8DI-M8-3P-C
- CPX-AP-I-8DI-M8-3P-D
- CPX-AP-I-8DI-M8-3P-E
- CPX-AP-I-8DI-M8-3P-F
- CPX-AP-I-8DI-M8-3P-G
- CPX-AP-I-8DI-M8-3P-H
- CPX-AP-I-8DI-M8-3P-I
- CPX-AP-I-8DI-M8-3P-J
- CPX-AP-I-8DI-M8-3P-K
- CPX-AP-I-8DI-M8-3P-L
- CPX-AP-I-8DI-M8-3P-M
- CPX-AP-I-8DI-M8-3P-N
- CPX-AP-I-8DI-M8-3P-O
- CPX-AP-I-8DI-M8-3P-P
- CPX-AP-I-8DI-M8-3P-Q
- CPX-AP-I-8DI-M8-3P-R
- CPX-AP-I-8DI-M8-3P-S
- CPX-AP-I-8DI-M8-3P-T
- CPX-AP-I-8DI-M8-3P-U
- CPX-AP-I-8DI-M8-3P-V
- CPX-AP-I-8DI-M8-3P-W
- CPX-AP-I-8DI-M8-3P-X
- CPX-AP-I-8DI-M8-3P-Y
- CPX-AP-I-8DI-M8-3P-Z