- Description: NF33/11-11 24-60V50/60HZ 20-60VDC Contactor relay
- Product ID: 1SBH137001R1139
- Extended Product Type: 1SBH137001R1139
- Product Net Weight: 0.320 kg
- Product Net Width: 45 mm
- Product Net Height: 86 mm
- Product Net Depth: 110.5 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Ambient Air Temperature: Close to Contactor for Storage -60...+80 C Near Contactor for Operation in Free Air -40 ... +70 C
- Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N14
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 6 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
- Terminal Type: Screw Terminals
- Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
- Number of Auxiliary Contacts NO: 3
- Number of Auxiliary Contacts NC: 3
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
- Climatic Withstand: Category B according to IEC 60947-1 Annex Q
- Tightening Torque UL/CSA: Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb
- Maximum Mechanical Switching Frequency: 6000 cycles per hour
- Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1...2.5 mm
- Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms
- Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm
- Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1 ... 2.5 mm
- EAN: 3471523107618
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Package Level 1 Width: 87 mm
- Package Level 1 Length: 113 mm
- Package Level 1 Height: 47 mm
- Package Level 1 Gross Weight: 0.32 kg
- Package Level 1 EAN: 3471523107618
- Package Level 2 Units: 36 piece
- Package Level 2 Width: 250 mm
- Package Level 2 Length: 300 mm
- Package Level 2 Height: 315 mm
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-5-1, q = 40 C 16 A
- Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I<sub>cw</sub>): for 0.1 s 140 A for 1 s 100 A
- Maximum Electrical Switching Frequency: AC-15 1200 cycles per hour DC-13 900 cycles per hour
- Rated Operational Current DC-13 (I<sub>e</sub>): (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (48 V) 2.8 A / 134 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W (72 V) 1 A / 72 W
- Resistance to Vibrations acc. to IEC 60068-2-6: 5...300 Hz 4 g closed position / 2 g open position
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 25 g Closed, Shock Direction: B2 15 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g
- Instructions and Manuals: 1SBC101027M6801
- ABS Certificate: ABS_15-GE1349500-PDA_90682247
- CB Certificate: CB_SE_70920A1M2
- CCC Certificate: CCC_2011010303465426
- cUL Certificate: UL_20130206_E252354-2-1
- Declaration of Conformity - CE: 1SBD250005U1000
- ETIM 4: EC000196 - Contactor relay
- ETIM 5: EC000196 - Contactor relay
- ETIM 6: EC000196 - Contactor relay
- Object Classification Code: K
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on NF33-11-11 . Santa Clara Systems carries 36,687 items from ABB.
- Nf33/11 Contactor Relays Are Used For Switching Auxiliary And Control Circuits Including Overlapping Of Lagging / Leading Contacts Nf Contactor Relays Include An Electronic Coil Interface Accepting A Wide Control Voltage Uc Min. ... Uc Max. Only Four Coils Cover Control Voltages Between 24...500 V 50/60 Hz. Nf Contactor Relays Can Manage Large Control Voltage Variations. One Coil Can Be Used For Different Control Voltages Used Worldwide Without Any Coil Change. Nf Contactor Relays Have Built-In Surge Protection And Do Not Require Additional Surge Suppressors. - Poles: 8-Pole Contactor Relays With A Non-Removable Front-Mounted Auxiliary Contact Block - Control Circuit: Ac Operated - Accessories: A Wide Range Of Accessories Is Available.
Alternates
- 1SBH137001R1139
- NF33/11 11
- NF33/1111
- NF331111
Common Typos
- NF33-11-1I
- NF33-11-1L
- NF33-11-I1
- NF33-11-II
- NF33-11-IL
- NF33-11-L1
- NF33-11-LI
- NF33-11-LL
- NF33-1I-11
- NF33-1I-1I
- NF33-1I-1L
- NF33-1I-I1
- NF33-1I-II
- NF33-1I-IL
- NF33-1I-L1
- NF33-1I-LI
- NF33-1I-LL
- NF33-1L-11
- NF33-1L-1I
- NF33-1L-1L
- NF33-1L-I1
- NF33-1L-II
- NF33-1L-IL
- NF33-1L-L1
- NF33-1L-LI
- NF33-1L-LL
Appended Numbers
- NF33-11-11-A
- NF33-11-11-B
- NF33-11-11-C
- NF33-11-11-D
- NF33-11-11-E
- NF33-11-11-F
- NF33-11-11-G
- NF33-11-11-H
- NF33-11-11-I
- NF33-11-11-J
- NF33-11-11-K
- NF33-11-11-L
- NF33-11-11-M
- NF33-11-11-N
- NF33-11-11-O
- NF33-11-11-P
- NF33-11-11-Q
- NF33-11-11-R
- NF33-11-11-S
- NF33-11-11-T
- NF33-11-11-U
- NF33-11-11-V
- NF33-11-11-W
- NF33-11-11-X
- NF33-11-11-Y
- NF33-11-11-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier