Product Summary:
- Product weight: 8.44 lb(US) (3.83 kg)
- Standards: EN 60947-1EN 60947-4-1IEC 60947-1JIS C8201-4-1IEC 60947-4-1
- Device short name: LC1F
- Width: 6.44 in (163.5 mm)
- Height: 6.38 in (162 mm)
- Description: Contactor
- Product weight: 8.44 lb(US) (3.83 kg)
- IP degree of protection: IP2x front face with shrouds (ordered separately) conforming to IEC 60529IP2x front face with shrouds (ordered separately) conforming to VDE 0106
- Standards: EN 60947-1EN 60947-4-1IEC 60947-1JIS C8201-4-1IEC 60947-4-1
- Device short name: LC1F
- Width: 6.44 in (163.5 mm)
- Height: 6.38 in (162 mm)
- Depth: 6.73 in (171 mm)
- Protective treatment: TH
- [Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C
- [Uimp] rated impulse withstand voltage: 8 kV
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Tightening torque: Power circuit: 88.5 lbf.in (10 N.m)
- Connections - terminals: Power circuit: connector 1 cable(s) 0.15 in² (95 mm²)Power circuit: lugs-ring terminals 1 cable(s) 0.15 in² (95 mm²)Power circuit: bar 2 x ( 20 x 3 mm)Power circuit : bolted connection
- Range: TeSys
- Mounting support: Plate
- [Ith] conventional free air thermal current: 200 A at <= 104 °F (40 °C)
- System Voltage: <= 1000 V AC 50/60 Hz<= 460 V DC
- Product name: TeSys F
- motor power kW: 55 kW at 380...400 V AC 50/60 Hz AC-359 kW at 415 V AC 50/60 Hz AC-359 kW at 440 V AC 50/60 Hz AC-375 kW at 500 V AC 50/60 Hz AC-365 kW at 1000 V AC 50/60 Hz AC-318.5 kW at 400 V AC 50/60 Hz AC-480 kW at 660?690 V AC 50/60 Hz AC-330 kW at 220...240 V AC 50/60 Hz AC-3
- [Ie] rated operational current: 200 A (<= 104 °F (40 °C)) at <= 440 V AC AC-1115 A (<= 131 °F (55 °C)) at <= 440 V AC AC-3
- Utilization category: AC-4AC-1AC-3
- Poles description: 3P
- Overvoltage category: III
- Associated fuse rating: 125 A aM at <= 440 V200 A gG at <= 440 V
- Product or component type: Contactor
- Ambient air temperature for operation: 23...131 °F (-5...55 °C)
- Irms rated making capacity: 1150 A AC conforming to IEC 60947-4-1
- Ambient air temperature for storage: -76...176 °F (-60...80 °C)
- Contactor application: Resistive loadMotor control
- Rated breaking capacity: 920 A conforming to IEC 60947-4-1
- Permissible ambient air temperature around the device: -40...158 °F (-40...70 °C)
- [Icw] rated short-time withstand current: 1100 A <= 104 °F (40 °C) 10 s640 A <= 104 °F (40 °C) 30 s520 A <= 104 °F (40 °C) 1 min400 A <= 104 °F (40 °C) 3 min320 A <= 104 °F (40 °C) 10 min
- Mechanical robustness: Vibrations contactor closed 6 Gn, 5...300 HzShocks contactor open 9 Gn for 11 msVibrations contactor open 2 Gn, 5...300 HzShocks contactor closed 15 Gn for 11 ms
- Pole contact composition: 3 NO
- Average impedance: 0.37 mOhm at 50 Hz - Ith 200 A
- Power dissipation per pole: 15 W AC-15 W AC-3
- Product certifications: BVCBULRMRoSCSARINALROS (Lloyds register of shipping)DNVABS
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1F115 . Santa Clara Systems carries 10,643 items from Telemecanique.
- Tesys F Contactor - 3p(3 No) - Ac-3 - <= 440 V 115 A - Without Coil
Alternates
Common Typos
- LC1F11S
- LC1F1I5
- LC1F1IS
- LC1F1L5
- LC1F1LS
- LC1FI15
- LC1FI1S
- LC1FII5
- LC1FIIS
- LC1FIL5
- LC1FILS
- LC1FL15
- LC1FL1S
- LC1FLI5
- LC1FLIS
- LC1FLL5
- LC1FLLS
- LCIF115
- LCIF11S
- LCIF1I5
- LCIF1IS
- LCIF1L5
- LCIF1LS
- LCIFI15
- LCIFI1S
- LCIFII5
Appended Numbers
- LC1F115-A
- LC1F115-B
- LC1F115-C
- LC1F115-D
- LC1F115-E
- LC1F115-F
- LC1F115-G
- LC1F115-H
- LC1F115-I
- LC1F115-J
- LC1F115-K
- LC1F115-L
- LC1F115-M
- LC1F115-N
- LC1F115-O
- LC1F115-P
- LC1F115-Q
- LC1F115-R
- LC1F115-S
- LC1F115-T
- LC1F115-U
- LC1F115-V
- LC1F115-W
- LC1F115-X
- LC1F115-Y
- LC1F115-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier