• Telemecanique LC1K09107M7 Barcode

LC1K09107M7

Let Us Find It

Current response time:

10 Minutes 53 Seconds
  • Description: TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 220...230 V AC coil
  • Product weight: 0.4 lb(US) (0.18 kg)
  • Range of product: TeSys K
  • IP degree of protection: IP2x conforming to VDE 0106
  • Standards: BS 5424, IEC 60947, NF C 63-110, VDE 0660
  • Device short name: LC1K
  • Width: 1.77 in (45 mm)
  • Depth: 2.24 in (57 mm)
  • Protective treatment: TC conforming to IEC 60068, TC conforming to DIN 50016
  • [Ui] rated insulation voltage: 690 V signaling circuit conforming to IEC 60947-4-1, 690 V signaling circuit conforming to IEC 60947-5-1, 600 V signaling circuit conforming to UL 508, 600 V power circuit conforming to CSA C22.2 No 14, 600 V signaling circuit conforming to CSA C22.2 No 14, 690 V power circuit conforming to IEC 60947-4-1, 600 V power circuit conforming to UL 508
  • [Uimp] rated impulse withstand voltage: 8 kV
  • Operating altitude: 6561.68 ft. (2000 m) without derating in temperature
  • Mechanical durability: 10 Mcycles
  • Connections - terminals: Faston terminals 1 6.35 mm, Faston terminals 2 2.8 mm
  • Range: TeSys
  • Mounting support: Plate, Rail
  • [Ith] conventional free air thermal current: 20 A at <= 122 F (50 C) power circuit, 10 A at <= 122 F (50 C) signaling circuit
  • System Voltage: 690 V AC 50/60 Hz power circuit, <= 690 V AC 50/60 Hz signaling circuit
  • Operating rate: 3600 cyc/h
  • Product name: TeSys K
  • [Uc] control circuit voltage: 220...230 V AC 50/60 Hz
  • Electrical durability: 0.18 Mcycles 20 A AC-1 at Ue <= 440 V, 1.3 Mcycles 9 A AC-3 at Ue <= 440 V
  • Insulation resistance: > 10 MOhm signaling circuit
  • motor power kW: 2.2 kW at 400 V AC 50/60 Hz AC-4, 2.2 kW at 220...230 V AC 50/60 Hz AC-3, 4 kW at 380...415 V AC 50/60 Hz AC-3, 4 kW at 440 V AC 50/60 Hz AC-3, 4 kW at 480 V AC 50/60 Hz AC-3, 4 kW at 500...600 V AC 50/60 Hz AC-3, 4 kW at 660...690 V AC 50/60 Hz AC-3
  • [Ie] rated operational current: 9 A at <= 440 V AC AC-3 power circuit, 20 A (<= 122 F (50 C)) at <= 440 V AC AC-1 power circuit, 16 A (<= 158 F (70 C)) at 690 V AC AC-1 power circuit
  • Utilization category: AC-1, AC-4, AC-3
  • Control circuit voltage limits: 0.2...0.75 Uc at <= 122 F (50 C) drop-out, 0.8...1.15 Uc at <= 122 F (50 C) operational
  • Poles description: 3P
  • Overvoltage category: III
  • Operating time: 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing
  • Associated fuse rating: 25 A gG at <= 440 V power circuit, 25 A aM power circuit, 10 A gG signaling circuit conforming to IEC 60947, 10 A gG signaling circuit conforming to VDE 0660
  • Control circuit type: AC 50/60 Hz
  • Product certifications: CSA, UL
  • Product or component type: Contactor
  • Pole contact composition: 3 NO
  • Ambient air temperature for storage: -58...176 F (-50...80 C)
  • Device application: Control
  • Contactor application: Motor control, Resistive load
  • Flame retardance: V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
  • Auxiliary contact composition: 1 NO
  • Irms rated making capacity: 110 A AC power circuit conforming to NF C 63-110, 110 A AC power circuit conforming to IEC 60947, 110 A AC signaling circuit conforming to IEC 60947
  • Rated breaking capacity: 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
  • [Icw] rated short-time withstand current: 20 A <= 50 C >= 15 min power circuit, 90 A <= 122 F (50 C) 1 s power circuit, 85 A <= 122 F (50 C) 5 s power circuit, 80 A <= 122 F (50 C) 10 s power circuit, 60 A <= 122 F (50 C) 30 s power circuit, 45 A <= 122 F (50 C) 1 min power circuit, 40 A <= 122 F (50 C) 3 min power circuit, 80 A 1 s signaling circuit, 90 A 500 ms signaling circuit, 110 A 100 ms signaling circuit
  • Average impedance: 3 mOhm at 50 Hz - Ith 20 A power circuit
  • inrush power in VA: 30 VA at 68 F (20 C)
  • hold-in power consumption in VA: 4.5 VA at 68 F (20 C)
  • Heat dissipation: 1.3 W
  • Auxiliary contacts type: Type instantaneous (1 NO)
  • Signaling circuit frequency: <= 400 Hz
  • Minimum switching current: 5 mA signaling circuit
  • Minimum switching voltage: 17 V signaling circuit
  • Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • Non overlap distance: 0.02 in (0.5 mm)
  • Mechanical robustness: Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6, Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1K09107M7 . Santa Clara Systems carries 10,298 items from Telemecanique.
  • Tesys K Contactor - 3p - Ac-3 <= 440 V 9 A - 1 No Aux. - 220...230 V Ac Coil

Alternates

    Common Typos

    • LC1K091O7M7
    • LC1K09I07M7
    • LC1K09IO7M7
    • LC1K09L07M7
    • LC1K09LO7M7
    • LC1KO9107M7
    • LC1KO91O7M7
    • LC1KO9I07M7
    • LC1KO9IO7M7
    • LC1KO9L07M7
    • LC1KO9LO7M7
    • LCIK09107M7
    • LCIK091O7M7
    • LCIK09I07M7
    • LCIK09IO7M7
    • LCIK09L07M7
    • LCIK09LO7M7
    • LCIKO9107M7
    • LCIKO91O7M7
    • LCIKO9I07M7
    • LCIKO9IO7M7
    • LCIKO9L07M7
    • LCIKO9LO7M7
    • LCLK09107M7
    • LCLK091O7M7
    • LCLK09I07M7

    Appended Numbers

    • LC1K09107M7-A
    • LC1K09107M7-B
    • LC1K09107M7-C
    • LC1K09107M7-D
    • LC1K09107M7-E
    • LC1K09107M7-F
    • LC1K09107M7-G
    • LC1K09107M7-H
    • LC1K09107M7-I
    • LC1K09107M7-J
    • LC1K09107M7-K
    • LC1K09107M7-L
    • LC1K09107M7-M
    • LC1K09107M7-N
    • LC1K09107M7-O
    • LC1K09107M7-P
    • LC1K09107M7-Q
    • LC1K09107M7-R
    • LC1K09107M7-S
    • LC1K09107M7-T
    • LC1K09107M7-U
    • LC1K09107M7-V
    • LC1K09107M7-W
    • LC1K09107M7-X
    • LC1K09107M7-Y
    • LC1K09107M7-Z

    More Products Like This

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo