LC7K0910B7
Out of Stock
Product Summary:
- Product weight: 26.68 lb(US) (12.1 kg)
- Range of product: TeSys D
- IP degree of protection: IP2x front face conforming to IEC 60529
- Standards: IEC 60947-4-1IEC 60947-5-1UL 508EN 60947-4-1CSA C22.2 No 14EN 60947-5-1
- Device short name: LC3D
- Description: TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V AC coil
- Product weight: 26.68 lb(US) (12.1 kg)
- Range of product: TeSys D
- IP degree of protection: IP2x front face conforming to IEC 60529
- Standards: IEC 60947-4-1IEC 60947-5-1UL 508EN 60947-4-1CSA C22.2 No 14EN 60947-5-1
- Device short name: LC3D
- Width: 17.72 in (450 mm)
- Height: 21.85 in (555 mm)
- Depth: 8.07 in (205 mm)
- Protective treatment: TH conforming to IEC 60068-2-30
- [Ui] rated insulation voltage: 600 V certifications CSA power circuit600 V certifications UL power circuit600 V certifications CSA signaling circuit600 V certifications UL signaling circuit1000 V conforming to IEC 60947-4-1 power circuit1000 V conforming to IEC 60947-1 signaling circuit
- [Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Mechanical durability: 8 Mcycles
- Tightening torque: 106.19 lbf.in (12 N.m) power circuit connector flat Ø 6...8 mm10.62 lbf.in (1.2 N.m)for control circuit connector flat Ø 6 mm10.62 lbf.in (1.2 N.m)for control circuit connector Philips No 2
- Connections - terminals: Connector power circuit 1 0.02...0.19 in² (10...120 mm²) flexible without cable endConnector power circuit 2 0.02...0.08 in² (10...50 mm²) flexible without cable endConnector power circuit 1 0.02...0.19 in² (10...120 mm²) flexible with cable endConnector power circuit 2 0.02...0.08 in² (10...50 mm²) flexible with cable endConnector power circuit 1 0.02...0.19 in² (10...120 mm²) solid without cable endConnector power circuit 2 0.02...0.08 in² (10...50 mm²) solid without cable endConnector for control circuit 1 0...0 in² (1...2.5 mm²) flexible without cable endConnector for control circuit 2 0...0 in² (1...2.5 mm²) flexible without cable endConnector for control circuit 1 0...0 in² (1...2.5 mm²) flexible with cable endConnector for control circuit 2 0...0 in² (1...2.5 mm²) flexible with cable endConnector for control circuit 1 0...0 in² (1...2.5 mm²) solid without cable endConnector for control circuit 2 0...0 in² (1...2.5 mm²) solid without cable end
- Range: TeSys
- Mounting support: Plate
- System Voltage: <= 690 V AC 25...400 Hz power circuit
- Operating rate: 30 cyc/hat <= 140 °F (60 °C)
- Product name: TeSys D
- [Uc] control circuit voltage: 110 V AC 50/60 Hz
- Electrical durability: 0.95 Mcycles 115 A AC-3 <= 440 V
- Insulation resistance: > 10 MOhm signaling circuit
- motor power kW: 110 kW at 380/400 V AC 50/60 Hz110 kW at 415 V AC 50/60 Hz110 kW at 440 V AC 50/60 Hz63 kWat 220/230 V AC 50/60 Hz
- [Ie] rated operational current: 115 A (<= 140 °F (60 °C)) AC AC-3for power circuit at <= 440 V
- Utilization category: AC-3
- Control circuit voltage limits: 0.3...0.5 Uc at 131 °F (55 °C) drop-out 50/60 Hz0.8...1.15 Uc at 131 °F (55 °C) operational 50/60 Hz
- Poles description: 3 x 3P
- Overvoltage category: III
- Control circuit type: AC 50/60 Hz
- Product or component type: Star delta starter
- Pollution degree: 3
- Starting time: 30 s
- Ambient air temperature for storage: -76...176 °F (-60...80 °C)
- Contactor application: Motor control
- Coil technology: Without built-in suppressor module
- Ambient air temperature for operation: -40...158 °F (-40...70 °C) at Uc
- Device presentation: Pre-wired
- inrush power in VA: 280...350 VAat 68 °F (20 °C) 0.8 60 Hz280...350 VAat 68 °F (20 °C) 0.8 50 Hz
- Fire resistance: 1562 °F (850 °C) conforming to IEC 60695-2-1
- hold-in power consumption in VA: 2...18 VAat 68 °F (20 °C) 0.3 60 Hz2...18 VAat 68 °F (20 °C) 0.3 50 Hz
- Flame retardance: V1 conforming to UL 94
- Pole contact composition: 3 x 3 NO
- Heat dissipation: 3...8 W at 50/60 Hz
- Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor closed 15 Gn for 11 msShocks contactor open 6 Gn for 11 ms
- Auxiliary contacts type: Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NCMirror contact conforming to IEC 60947-4-1 3 x 1 NC
- Signaling circuit frequency: 25...400 Hz
- Minimum switching current: For signaling circuit
- Switching voltage: 17 Vfor signaling circuit
- Non-overlap time: 1.5 ms on energisation between NC and NO contact1.5 ms on de-energisation between NC and NO contact
- Auxiliary contact composition: 1 NC KM2 line contactor1 NO KM3 delta contactor
- Interlocking type: Mechanical
- Product certifications: CSALROS (Lloyds register of shipping)RINABVGOSTDNVGLCCCUL
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC7K0910B7 . Santa Clara Systems carries 10,643 items from Telemecanique.
- Tesys K Contactor - 3p - Ac-3 <= 440 V 9 A - 1 No Aux. - 24 V Ac Coil
Alternates
Common Typos
- 1C7K091087
- 1C7K0910B7
- 1C7K091OB7
- LC7K091087
- LC7K091O87
- LC7K091OB7
- LC7K09I087
- LC7K09I0B7
- LC7K09IO87
- LC7K09IOB7
- LC7K09L087
- LC7K09L0B7
- LC7K09LO87
- LC7K09LOB7
- LC7KO91087
- LC7KO910B7
- LC7KO91O87
- LC7KO91OB7
- LC7KO9I087
- LC7KO9I0B7
- LC7KO9IO87
- LC7KO9IOB7
- LC7KO9L087
- LC7KO9L0B7
- LC7KO9LO87
- LC7KO9LOB7
Appended Numbers
- LC7K0910B7-A
- LC7K0910B7-B
- LC7K0910B7-C
- LC7K0910B7-D
- LC7K0910B7-E
- LC7K0910B7-F
- LC7K0910B7-G
- LC7K0910B7-H
- LC7K0910B7-I
- LC7K0910B7-J
- LC7K0910B7-K
- LC7K0910B7-L
- LC7K0910B7-M
- LC7K0910B7-N
- LC7K0910B7-O
- LC7K0910B7-P
- LC7K0910B7-Q
- LC7K0910B7-R
- LC7K0910B7-S
- LC7K0910B7-T
- LC7K0910B7-U
- LC7K0910B7-V
- LC7K0910B7-W
- LC7K0910B7-X
- LC7K0910B7-Y
- LC7K0910B7-Z
More Products Like This
-
LC1 D0901F6
Telemecanique
-
LC1 D12004G6
Telemecanique
-
LC1 D1810M6
Telemecanique
-
LC1 D3210B7
Telemecanique
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier