• Telemecanique SR3XT43BD Barcode

SR3XT43BD

Product Summary:

  • Product weight: 0.24 lb(US) (0.11 kg)
  • Range of product: Zelio Logic
  • Operating altitude: 6561.68 ft. (2000 m)
  • Tightening torque: 4.42 lbf.in (0.5 N.m)
  • Relative humidity: 95 % without condensation or dripping water
Let Us Find It

Current response time:

By 5AM PT on Wednesday
  • Description: analogue I/O extension module - 4 I O - 24 V DC - for Zelio Logic
  • Product weight: 0.24 lb(US) (0.11 kg)
  • Range of product: Zelio Logic
  • IP degree of protection: IP20 (terminal block) conforming to IEC 60529IP40 (front panel) conforming to IEC 60529
  • Standards: EN/IEC 61000-4-11EN/IEC 61000-4-6 level 3EN/IEC 61000-4-12EN/IEC 60068-2-6 FcEN/IEC 61000-4-3EN/IEC 61000-4-4 level 3EN/IEC 60068-2-27 EaEN/IEC 61000-4-5EN/IEC 61000-4-2 level 3
  • Operating altitude: 6561.68 ft. (2000 m)
  • Tightening torque: 4.42 lbf.in (0.5 N.m)
  • Connections - terminals: Screw terminals, 1 x 0.25...1 x 2.5 mm², AWG 24...AWG 14, semi-solid cableScrew terminals, 1 x 0.25...1 x 2.5 mm², AWG 24...AWG 14, solid cableScrew terminals, 2 x 0.25...2 x 1.5 mm², AWG 23...AWG 16, solid cableScrew terminals, 1 x 0.25...1 x 2.5 mm², AWG 24...AWG 14, flexible cable with cable endScrew terminals, 2 x 0.25...2 x 0.75 mm², AWG 24...AWG 18, flexible cable with cable end
  • Relative humidity: 95 % without condensation or dripping water
  • Analogue input number: 2
  • Product certifications: GOSTCSAC-TickUL
  • Product or component type: Analogue I/O extension module
  • Analogue input type: Common mode
  • Analogue input range: -25...125 °C0...20 mA0...10 V
  • Temperature probe type: Pt 100, 3-wire conforming to IEC 751
  • Environmental characteristic: EMC directive conforming to EN/IEC 61000-6-2EMC directive conforming to EN/IEC 61000-6-3EMC directive conforming to EN/IEC 61000-6-4EMC directive conforming to EN/IEC 61131-2 zone BLow voltage directive conforming to EN/IEC 61131-2
  • Maximum permissible voltage: 30 V analogue input circuit
  • Disturbance radiated/conducted: Class B conforming to EN 55022-11 group 1
  • [Imp] maximum permanent current: 30 mA analogue input circuit
  • Pollution degree: 2 conforming to EN/IEC 61131-2
  • Analogue input resolution: 10 bits on the input range
  • Ambient air temperature for operation: -4...131 °F (-20...55 °C) conforming to IEC 60068-2-1 and IEC 60068-2-2-4...104 °F (-20...40 °C) conforming to IEC 60068-2-1 and IEC 60068-2-2
  • Input impedance: 18 kOhm, input range: 0...10 V analogue input circuit247 Ohm, input range: 0...20 mA for analogue input circuit
  • Ambient air temperature for storage: -40...158 °F (-40...70 °C)
  • Analogue output number: 2
  • Analogue output range: 0...10 V
  • Altitude transport: <= 10000 ft. (3048 m)
  • Analogue output resolution: 10 bits on the output range
  • Load type: Resistive load analogue output
  • Maximum load current: 10 mA analogue output
  • Short-circuit protection: With analogue output
  • LSB value: 0.15 °C, - 25...125 °C analogue input circuit20 µA, 0...20 mA analogue input circuit9.8 mV, 0...10 V analogue input circuit9.8 mV, 0...10 V analogue output
  • Conversion time: Smart relay cycle time analogue input circuitSmart relay cycle time analogue output
  • Conversion error: +/- 1 % of the full scale value, input range: 0...10 V (77 °F (25 °C))for analogue output+/- 1 % of the full scale value, input range: 0...10 V (131 °F (55 °C))for analogue output+/- 1 %, input range: 0...10 V (77 °F (25 °C))for analogue input circuit+/- 1 %, input range: 0...10 V (131 °F (55 °C))for analogue input circuit+/- 1 %, input range: 0...20 mA (77 °F (25 °C))for analogue input circuit+/- 1 %, input range: 0...20 mA (131 °F (55 °C))for analogue input circuit+/- 1.5 °C, input range: - 25...125 °C (77 °F (25 °C))for analogue input circuit+/- 1.5 °C, input range: - 25...125 °C (131 °F (55 °C))for analogue input circuit
  • Repeat accuracy: < +/- 0.3 °C, input range: - 25...125 °Cat 77 °F (25 °C)for analogue input circuit<= +/- 1 %, input range: 0...10 Vat 77 °F (25 °C)for analogue input circuit<= +/- 1 %, input range: 0...10 Vat 131 °F (55 °C)for analogue output<= +/- 1 %, input range: 0...20 mAat 77 °F (25 °C)for analogue input circuit
  • Operating distance: 10 m with screened cable analogue input circuit10 m with screened cable analogue output
  • Reverse polarity protection: With analogue input circuit
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on SR3XT43BD . Santa Clara Systems carries 10,643 items from Telemecanique.
  • Analogue I/o Extension Module - 4 I O - 24 V Dc - For Zelio Logic

Alternates

    Common Typos

    • 5R3XT438D
    • 5R3XT43BD
    • SR3XT438D

    Appended Numbers

    • SR3XT43BD-A
    • SR3XT43BD-B
    • SR3XT43BD-C
    • SR3XT43BD-D
    • SR3XT43BD-E
    • SR3XT43BD-F
    • SR3XT43BD-G
    • SR3XT43BD-H
    • SR3XT43BD-I
    • SR3XT43BD-J
    • SR3XT43BD-K
    • SR3XT43BD-L
    • SR3XT43BD-M
    • SR3XT43BD-N
    • SR3XT43BD-O
    • SR3XT43BD-P
    • SR3XT43BD-Q
    • SR3XT43BD-R
    • SR3XT43BD-S
    • SR3XT43BD-T
    • SR3XT43BD-U
    • SR3XT43BD-V
    • SR3XT43BD-W
    • SR3XT43BD-X
    • SR3XT43BD-Y
    • SR3XT43BD-Z

    More Products Like This

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo