SR3XT61JD
Out of Stock
Product Summary:
- Product weight: 0.28 lb(US) (0.125 kg)
- Range of product: Zelio Logic
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 10000000 cycles (relay output)
- Tightening torque: 4.42 lbf.in (0.5 N.m)
- Description: discrete I/O extension module - 6 I O - 12 V DC - for Zelio Logic
- Product weight: 0.28 lb(US) (0.125 kg)
- Range of product: Zelio Logic
- IP degree of protection: IP20 (terminal block) conforming to IEC 60529IP40 (front panel) conforming to IEC 60529
- Standards: EN/IEC 61000-4-2 level 3EN/IEC 61000-4-5EN/IEC 61000-4-12EN/IEC 61000-4-6 level 3EN/IEC 60068-2-6 FcEN/IEC 60068-2-27 EaEN/IEC 61000-4-3EN/IEC 61000-4-11EN/IEC 61000-4-4 level 3
- [Uimp] rated impulse withstand voltage: 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 10000000 cycles (relay output)
- Tightening torque: 4.42 lbf.in (0.5 N.m)
- Connections - terminals: Screw terminals, flexible cable with cable end 1 x 0.25...1 x 2.5 mm² / AWG 24...AWG 14 AWGScrew terminals, flexible cable with cable end 2 x 0.25...2 x 0.75 mm² / AWG 24...AWG 18 AWGScrew terminals, semi-solid cable 1 x 0.2...1 x 2.5 mm² / AWG 25...AWG 14 AWGScrew terminals, solid cable 1 x 0.2...1 x 2.5 mm² / AWG 25...AWG 14 AWGScrew terminals, solid cable 2 x 0.2...2 x 1.5 mm² / AWG 24...AWG 16 AWG
- Electrical durability: 500000 cycles at 230 V, 0.9 A (AC-15)for relay output conforming to EN/IEC 60947-5-1500000 cycles at 230 V, 1.5 A (AC-12)for relay output conforming to EN/IEC 60947-5-1500000 cycles at 24 V, 0.6 A (DC-13)for relay output conforming to EN/IEC 60947-5-1500000 cycles at 24 V, 1.5 A (DC-12)for relay output conforming to EN/IEC 60947-5-1
- [Us] rated supply voltage: 12 V DC
- Overvoltage category: III conforming to EN/IEC 60664-1
- Relative humidity: 95 % without condensation or dripping water
- Response time: 10 ms (from state 0 to state 1) relay output5 ms (from state 1 to state 0) relay output
- Number or control scheme lines: 120 with ladder programming
- Product certifications: CSAGOSTC-TickGLUL
- Product or component type: Discrete I/O extension module
- Cycle time: 6...90 ms
- Backup time: 10 years at 77 °F (25 °C)
- Clock drift: 12 min/year at 32...131 °F (0...55 °C)
- Environmental characteristic: EMC directive conforming to EN/IEC 61000-6-2EMC directive conforming to EN/IEC 61000-6-3EMC directive conforming to EN/IEC 61000-6-4EMC directive conforming to EN/IEC 61131-2 zone BLow voltage directive conforming to EN/IEC 61131-2
- Checks: Program memory on each power up
- Disturbance radiated/conducted: Class B conforming to EN 55022-11 group 1
- Pollution degree: 2 conforming to EN/IEC 61131-2
- Supply voltage limits: 10.4...14.4 V
- Ambient air temperature for operation: -4...104 °F (-20...40 °C) in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2-4...131 °F (-20...55 °C) conforming to IEC 60068-2-1 and IEC 60068-2-2
- Reverse polarity protection: With
- Ambient air temperature for storage: -40...158 °F (-40...70 °C)
- Discrete input number: 4 conforming to EN/IEC 61131-2 type 1
- Discrete input type: Resistive
- Altitude transport: <= 10000 ft. (3048 m)
- Discrete input voltage: 12 V DC
- Discrete input current: 4 mA
- Counting frequency: 1 kHz for discrete input
- Voltage state 1 guaranteed: >= 7 Vfor IB...IG used as discrete input circuit>= 5.6 Vfor I1...IA and IH...IR discrete input circuit
- Voltage state 0 guaranteed: <= 3 Vfor IB...IG used as discrete input circuit<= 2.4 Vfor I1...IA and IH...IR discrete input circuit
- Current state 1 guaranteed: >= 2 mA for I1...IA and IH...IR discrete input circuit>= 0.5 mA for IB...IG used as discrete input circuit
- Current state 0 guaranteed: <= 0.2 mA for IB...IG used as discrete input circuit<= 0.9 mA for I1...IA and IH...IR discrete input circuit
- Input compatibility: 3-wire proximity sensors PNP (discrete input)
- Input impedance: 14 kOhm (IB...IG used as discrete input circuit)2.7 kOhm (I1...IA and IH...IR discrete input circuit)
- Number of outputs: 2 relay output(s)
- Output voltage limits: 24...250 V AC (relay output)5...30 V DC (relay output)
- Contacts type and composition: NO relay output
- Output thermal current: 8 A for all 2 outputs (relay output)
- switching capacity in mA: >= 10 mAat 12 V (relay output)
- operating rate in Hz: 0.1 Hz (at Ie)for relay output10 Hz (no load)for relay output
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on SR3XT61JD . Santa Clara Systems carries 10,643 items from Telemecanique.
- Discrete I/o Extension Module - 6 I O - 12 V Dc - For Zelio Logic
Alternates
Common Typos
- 5R3XT61JD
- 5R3XT6IJD
- 5R3XT6LJD
- 5R3XTG1JD
- 5R3XTGIJD
- 5R3XTGLJD
- SR3XT6IJD
- SR3XT6LJD
- SR3XTG1JD
- SR3XTGIJD
- SR3XTGLJD
Appended Numbers
- SR3XT61JD-A
- SR3XT61JD-B
- SR3XT61JD-C
- SR3XT61JD-D
- SR3XT61JD-E
- SR3XT61JD-F
- SR3XT61JD-G
- SR3XT61JD-H
- SR3XT61JD-I
- SR3XT61JD-J
- SR3XT61JD-K
- SR3XT61JD-L
- SR3XT61JD-M
- SR3XT61JD-N
- SR3XT61JD-O
- SR3XT61JD-P
- SR3XT61JD-Q
- SR3XT61JD-R
- SR3XT61JD-S
- SR3XT61JD-T
- SR3XT61JD-U
- SR3XT61JD-V
- SR3XT61JD-W
- SR3XT61JD-X
- SR3XT61JD-Y
- SR3XT61JD-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier