- Description: Overload Relay
- Product weight: 0.32 lb(US) (0.144 kg)
- IP degree of protection: IP20 conforming to IEC 60529
- Standards: IEC 60947-4-1UL 508IEC 60947-5-1EN 60947-5-1EN 60947-4-1ATEX D 94/9/CECSA C22.2 No 14
- Device short name: LRD
- Width: 1.77 in (45 mm)
- Depth: 3 in (76.1 mm)
- Protective treatment: TH conforming to IEC 60068
- [Ui] rated insulation voltage: 600 V power circuit conforming to CSA600 V power circuit conforming to UL690 V power circuit conforming to IEC 60947-4-1
- [Uimp] rated impulse withstand voltage: 6 kV
- Tightening torque: Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminalsPower circuit: 22.12 lbf.in (2.5 N.m) - on screw clamp terminals
- Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: solid - without cable endPower circuit: screw clamp terminals 1 cable(s) 0...0.02 in² (1.5...10 mm²) - cable stiffness: flexible - without cable endPower circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...6 mm²) - cable stiffness: flexible - with cable endPower circuit: screw clamp terminals 1 cable(s) 0...0.02 in² (1.5...10 mm²) - cable stiffness: solid - without cable end
- Range: TeSys
- Mounting support: Plate with specific accessoriesRail with specific accessoriesUnder contactor
- [Ith] conventional free air thermal current: 5 A for signaling circuit
- System Voltage: 690 V AC 0...400 Hz
- Product name: TeSys LRD
- Associated fuse rating: 25 A aM50 A gG50 A BS88
- Control type: Red push-button stopBlue push-button for reset mode
- Network frequency: 0...400 Hz
- Product or component type: Differential thermal overload relay
- Tripping threshold: 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
- Ambient air temperature for operation: Without derating conforming to IEC 60947-4-1
- Ambient air temperature for storage: -76...158 °F (-60...70 °C)
- Relay application: Motor protection
- Permissible current: 3 A at 120 V AC-15 for signaling circuit0.22 A at 125 V DC-13 for signaling circuit
- Mechanical robustness: Vibrations 3 Gn IEC 60068-2-6Shocks 15 Gn for 11 ms IEC 60068-2-7
- Product compatibility: LC1D32LC1D25LC1D38
- Dielectric strength: 6 kVat 50 Hz conforming to IEC 60255-5
- Network type: ACDC
- Thermal protection adjustment range: 17...24 A
- Product certifications: ATEX INERISCSAEACULABS
- Phase failure sensitivity: Tripping current 130 % of Ir on two phase, the last one at 0
- Temperature compensation: -4...140 °F (-20...60 °C)
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LRD22L . Santa Clara Systems carries 10,632 items from Telemecanique.
- Tesys Lrd Thermal Overload Relays - 17...24 A - Class 20
Alternates
Common Typos
- 1RD221
- 1RD22I
- 1RD22L
- 1RD2Z1
- 1RD2ZI
- 1RD2ZL
- 1RDZ21
- 1RDZ2I
- 1RDZ2L
- 1RDZZ1
- 1RDZZI
- 1RDZZL
- IRD221
- IRD22I
- IRD22L
- LRD221
- LRD22I
- LRD2Z1
- LRD2ZI
- LRD2ZL
- LRDZ21
- LRDZ2I
- LRDZ2L
- LRDZZ1
- LRDZZI
- LRDZZL
Appended Numbers
- LRD22L-A
- LRD22L-B
- LRD22L-C
- LRD22L-D
- LRD22L-E
- LRD22L-F
- LRD22L-G
- LRD22L-H
- LRD22L-I
- LRD22L-J
- LRD22L-K
- LRD22L-L
- LRD22L-M
- LRD22L-N
- LRD22L-O
- LRD22L-P
- LRD22L-Q
- LRD22L-R
- LRD22L-S
- LRD22L-T
- LRD22L-U
- LRD22L-V
- LRD22L-W
- LRD22L-X
- LRD22L-Y
- LRD22L-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier