• Telemecanique LUB12 power base - TeSys U - 12 A - screw clamps control Product Image
  • Telemecanique LUB12 power base - TeSys U - 12 A - screw clamps control Product Image
  • Telemecanique LUB12 power base - TeSys U - 12 A - screw clamps control Product Image
  • Telemecanique LUB12 power base - TeSys U - 12 A - screw clamps control Product Image
  • Telemecanique LUB12 Barcode

LUB12

Get a Quote

Current response time:

13 Minutes 27 Seconds
  • Description: power base - TeSys U - 12 A - screw clamps control
  • Product weight: 1.98 lb(US) (0.9 kg)
  • IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1
  • Standards: CSA C22.2 No 14 type E, EN 60947-6-2, IEC 60947-6-2, UL 508 type E with phase barrier
  • Device short name: LUB
  • Width: 1.77 in (45 mm)
  • Height: 5.71 in (145 mm)
  • Depth: 4.96 in (126 mm)
  • Protective treatment: TH conforming to IEC 60068
  • [Ui] rated insulation voltage: 600 V conforming to CSA C22.2 No 14, 600 V conforming to UL 508, 690 V conforming to IEC 60947-1 3
  • [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
  • Operating altitude: 6561.68 ft. (2000 m)
  • Mechanical durability: 15000000 cycles
  • Tightening torque: Control circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) flat, Control circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) Philips no 1, Power circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) flat, Power circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) Philips No 2
  • Connections - terminals: Power circuit: screw clamp terminals 2 cable 0...0.01 in (1.5...6 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 1 cable 0...0 in (0.34...1.5 mm) - cable stiffness: flexible - with cable end, Control circuit: screw clamp terminals 1 cable 0...0 in (0.75...1.5 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 1 cable 0...0 in (0.75...1.5 mm) - cable stiffness: rigid - without cable end, Control circuit: screw clamp terminals 2 cable 0...0 in (0.34...1.5 mm) - cable stiffness: flexible - with cable end, Control circuit: screw clamp terminals 2 cable 0...0 in (0.75...1.5 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 2 cable 0...0 in (0.75...1.5 mm) - cable stiffness: rigid - without cable end, Power circuit: screw clamp terminals 1 cable 0...0.02 in (1...10 mm) - cable stiffness: rigid - without cable end, Power circuit: screw clamp terminals 1 cable 0...0.01 in (1...6 mm) - cable stiffness: flexible - with cable end, Power circuit: screw clamp terminals 1 cable 0...0.02 in (2.5...10 mm) - cable stiffness: flexible - without cable end, Power circuit: screw clamp terminals 2 cable 0...0.01 in (1...6 mm) - cable stiffness: flexible - with cable end, Power circuit: screw clamp terminals 2 cable 0...0.01 in (1...6 mm) - cable stiffness: rigid - without cable end
  • Range: TeSys
  • [Ith] conventional free air thermal current: 12:00 AM
  • System Voltage: 230 V, 440 V, 500 V, 690 V
  • Operating rate: 60 cyc/mn
  • Product name: TeSys U
  • [Uc] control circuit voltage: 110...220 V DC, 110...240 V AC 50/60 Hz, 24 V AC 50/60 Hz, 24 V DC, 48 V AC 50/60 Hz, 48...72 V DC
  • Shock resistance: 10 gn power poles open conforming to IEC 60068-2-27, 15 gn power poles closed conforming to IEC 60068-2-27
  • Vibration resistance: 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-27, 4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-27
  • [Ie] rated operational current: 12 A at <= 440 V, 12 A at 500 V, 9 A at 690 V
  • Utilization category: AC-41, AC-43, AC-44
  • Poles description: 3P
  • Operating time: 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit, 50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 75 ms closing with LUCM control circuit
  • Auxiliary contact composition: 1 NO + 1 NC
  • Heat dissipation: 2 W for control circuit with LUCA, LUCB, LUCC, LUCD, 1.7 W for control circuit with LUCM
  • Auxiliary contacts type: Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1, Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1
  • Immunity to micro breaks: 3 ms
  • Immunity to voltage dips: 70 % 500 ms conforming to IEC 61000-4-11
  • Product or component type: Non reversing power base
  • Network frequency: 40...60 Hz
  • Product certifications: BV, ATEX, LROS (Lloyds register of shipping), UL, GOST, GL, ABS, ASEFA, DNV, CSA, CCC
  • Device application: Motor
  • [Ics] rated service breaking capacity: 10 kA 500 V, 4 kA 690 V, 50 kA 230 V, 50 kA 440 V
  • Suitability for isolation: Yes
  • Typical current consumption: 130 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 140 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 150 mA at 24 V DC I maximum while closing with LUCM, 280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 35 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 60 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 70 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 70 mA at 24 V DC I rms sealed with LUCM
  • Safety reliability level: B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • Ambient air temperature for operation: -13...140 F (-25...60 C) with LUCM, -13...158 F (-25...70 C) with LUCA, LUCB, LUCC, LUCD
  • Ambient air temperature for storage: -40...185 F (-40...85 C)
  • Fire resistance: 1202 F (650 C) conforming to IEC 60695-2-12, 1760 F (960 C) parts supporting live components conforming to IEC 60695-2-12
  • Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N, 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
  • Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2, 8 kV level 4 on contact conforming to IEC 61000-4-2
  • Resistance to radiated fields: 9.14 V/yd (10 V/m) 3 conforming to IEC 61000-4-3
  • Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4, 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
  • Non-dissipating shock wave: 1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2, 1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2, 2 kV common mode 24...240 V AC conforming to IEC 60947-6-2, 2 kV common mode 48...220 V DC conforming to IEC 60947-6-2
  • Immunity to radio electric fields: 10 V conforming to IEC 61000-4-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LUB12 . Santa Clara Systems carries 10,296 items from Telemecanique.
  • Power Base - Tesys U - 12 A - Screw Clamps Control

Alternates

    Common Typos

    • 1U812
    • 1U81Z
    • 1U8I2
    • 1U8IZ
    • 1U8L2
    • 1U8LZ
    • 1UB12
    • 1UB1Z
    • 1UBI2
    • 1UBIZ
    • 1UBL2
    • 1UBLZ
    • IUB12
    • IUB1Z
    • IUBI2
    • LU812
    • LU81Z
    • LU8I2
    • LU8IZ
    • LU8L2
    • LU8LZ
    • LUB1Z
    • LUBI2
    • LUBIZ
    • LUBL2
    • LUBLZ

    Appended Numbers

    • LUB12-A
    • LUB12-B
    • LUB12-C
    • LUB12-D
    • LUB12-E
    • LUB12-F
    • LUB12-G
    • LUB12-H
    • LUB12-I
    • LUB12-J
    • LUB12-K
    • LUB12-L
    • LUB12-M
    • LUB12-N
    • LUB12-O
    • LUB12-P
    • LUB12-Q
    • LUB12-R
    • LUB12-S
    • LUB12-T
    • LUB12-U
    • LUB12-V
    • LUB12-W
    • LUB12-X
    • LUB12-Y
    • LUB12-Z

    More Products Like This

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo